Manual National Instruments Isolated Analog Output Module SCC-AO10

12 pages 0.29 mb
Download

Go to site of 12

Summary
  • National Instruments Isolated Analog Output Module SCC-AO10 - page 1

    USER GUIDE SCC-AO10 Isolated Analog Output Module The SCC-AO10 is an isolated voltage output module wit h an output range of ±10 V. The output voltage level is controlled by the DA C output of an E/M Series DAQ device. You can incr ease the output voltage level to ±20 V by connect ing two SCC-AO 10 modules in series. Conventions The following con ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 2

    SCC-AO10 Isolated Analog Output Module Use r Guide 2 ni.com monospace T e xt in this font denotes text or ch aracters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper na mes of disk dri ves, paths, directories, programs, subprograms, su broutines, d e vice na ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 3

    © National Instruments Corpor ation 3 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Note Software scaling of measurements is not supported on the Macintosh operating system. Refer to the SCC-AO10 Connector Pin Assignments section. Y ou can do wnload NI documents from ni.com/manuals . T o do wnload the latest version of NI-D A Qmx, click Do w ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 4

    SCC-AO10 Isolated Analog Output Module Use r Guide 4 ni.com Figures 1 and 2 show the SCC-A O10 c onnected to a nonreferenced load and to a load w ith a hi gh common-mode voltage. Figure 1. SCC-AO10 Connected to a Nonreferenced Load Figure 2. SCC-AO10 Connected to a Load with a High Common-Mode Voltage Connecting T wo SCC-AO10 Modules in Series You ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 5

    © National Instruments Corpor ation 5 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Figure 3. Connecting T wo SCC-AO10 Modules in Series The SC-2345/2350 routes the E/M Series D A Q device analog output channels A O 0 and A O 1 to the SCC-A O10 modules, and the resu lting maximum output voltage range is ±20 V . Refer to Figure 3 and use the ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 6

    SCC-AO10 Isolated Analog Output Module Use r Guide 6 ni.com Using the SCC-AO10 This section contains information regarding scali ng voltage measurements and isolated ground references. Scaling V oltage Measurements The SCC-AO10 is a ±10 V isolated analog output module. The output voltage is controlled by an E/M Series DAQ device AO output channel, ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 7

    © National Instruments Corpor ation 7 SCC-AO10 Isolated Analog Output Mo dule U ser Guide 5. Adjust the offset potentiometer on the top of the SCC-A O10 unt il the voltmeter reads 0 VDC ±100 μ V . The of fset is no w calibrated. 6. Using your software, hav e A O ( X ) output 9.9 VDC. Adjust the gain potentiometer on the to p of the SCC-A O10 unt ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 8

    SCC-AO10 Isolated Analog Output Module Use r Guide 8 ni.com Power Requirement Analog power ............... ................. .........180 mW max at full load 172 mW max w ith no load + 15 V .... ................. .............. ............6 mA max at full load 5.73 mA max with no load –15 V ............ ................. .............. ....6 mA ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 9

    © National Instruments Corpor ation 9 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Maximum W orking Voltage (Signal + common- mode) each input should remain within 42.4 V peak or 60 VDC of ground. Maximum working voltage refers to the signal voltage plus the CMV . Channel-to-earth (inputs) ....................... 42.4 V peak or 60 VDC, Meas ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 10

    SCC-AO10 Isolated Analog Out put Module Use r Guide 10 ni.com Safety This product meets the requirements of the follow ing standards of safety for electrical equipment for measurement, contro l, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certifications , refer to the product label or th ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 11

    © National Instruments Corpor ation 11 SCC-AO10 Isolat ed Analog Output Module User Guide Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible man ner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For ...

  • National Instruments Isolated Analog Output Module SCC-AO10 - page 12

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e information a bout National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trad e names of their respective companie s. For patents covering Nati ...

Manufacturer National Instruments Category Network Card

Documents that we receive from a manufacturer of a National Instruments Isolated Analog Output Module SCC-AO10 can be divided into several groups. They are, among others:
- National Instruments technical drawings
- Isolated Analog Output Module SCC-AO10 manuals
- National Instruments product data sheets
- information booklets
- or energy labels National Instruments Isolated Analog Output Module SCC-AO10
All of them are important, but the most important information from the point of view of use of the device are in the user manual National Instruments Isolated Analog Output Module SCC-AO10.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals National Instruments Isolated Analog Output Module SCC-AO10, service manual, brief instructions and user manuals National Instruments Isolated Analog Output Module SCC-AO10. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product National Instruments Isolated Analog Output Module SCC-AO10.

A complete manual for the device National Instruments Isolated Analog Output Module SCC-AO10, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use National Instruments Isolated Analog Output Module SCC-AO10 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of National Instruments Isolated Analog Output Module SCC-AO10.

A complete National Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual National Instruments Isolated Analog Output Module SCC-AO10 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the National Instruments Isolated Analog Output Module SCC-AO10, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the National Instruments Isolated Analog Output Module SCC-AO10, that we can find in the current document
3. Tips how to use the basic functions of the device National Instruments Isolated Analog Output Module SCC-AO10 - which should help us in our first steps of using National Instruments Isolated Analog Output Module SCC-AO10
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with National Instruments Isolated Analog Output Module SCC-AO10
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of National Instruments Isolated Analog Output Module SCC-AO10 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning National Instruments Isolated Analog Output Module SCC-AO10?

Use the form below

If you did not solve your problem by using a manual National Instruments Isolated Analog Output Module SCC-AO10, ask a question using the form below. If a user had a similar problem with National Instruments Isolated Analog Output Module SCC-AO10 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)