    POR T ABLE FORCED AIR HEA TER OWNER’S MANUAL IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. Heater Sizes: RJ45 And RJ70 ...

  • Desa RJ45 - page 2

    2 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater . Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the ? ...

  • Desa RJ45 - page 3

    3 104950 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - RJ45 Handle Fuel Cap Lower Shell Power Cord Fuel Tank Hot Air Outlet Air Filter End Cover Fan Guard Upper Shell Side Cover Ignition Control Assembly (assembly on inside of side cover) Handle Fuel Cap Lower Shell Power Cord Fuel Tank Hot Air Outlet Air Filter End Cover Fan Guard Upper Shel ...

  • Desa RJ45 - page 4

    4 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 Figure 3 - Cross Section Operational View Fuel Filter Air Line To Burner Air Output Filter Air Pump Air Intake Filter Cool Air In Fan Combustion Chamber Ignitor or Spark Plug Motor Clean Heated Air Out Ignition Control Assembly or Electronic Ignitor Air For Fuel System Air For Combustion And Hea ...

  • Desa RJ45 - page 5

    5 104950 OWNER’S MANUAL Item Fuel tank Air output and lint filters Air intake filter Fuel filter RJ45: Ignitor RJ70: Spark Plug Fan blades Motor WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. STORING, TRANSPOR TING, OR SHIPPING Note: If shipping, transport companies re- qui ...

  • Desa RJ45 - page 6

    6 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 TROUBLESHOOTING RJ45 WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. REMEDY 1. Check circuit breaker in electrical panel 2. Check all electrical connections. See W iring Diag rams, page 12 3. If fan does not turn freely , see ...

  • Desa RJ45 - page 7

    7 104950 OWNER’S MANUAL TROUBLESHOOTING Continued RJ70 WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. OBSERVED FAULT Heater ignites, but flame-out control shuts off heater after a short period of time Heater will not ignite, but motor runs for a short period of time Motor does ...

  • Desa RJ45 - page 8

    8 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 PUMP PRESSURE ADJUSTMENT 1. Remove pressure gauge plug from filter end cover . 2. Install accessory pressure gauge (part number HA1 180). 3. Start heater (see Opera tion , page 5). Al- low motor to reach full speed. 4. Using a flat blade screwdriver , adjust pressure. T urn relief valve to righ ...

  • Desa RJ45 - page 9

    9 104950 OWNER’S MANUAL Fuel Filter Side Cover Upper Fuel Line Figure 9 - Fuel Filter Removal FUEL FILTER 1. Remove side cover screws using 5/16" nut-driver (see Figure 9). 2. Remove side cover . 3. Pull upper fuel line off fuel filter neck. 4. Carefully pry bushing and fuel filter out of fuel tank. 5. W ash fuel filter with clean fuel an ...

  • Desa RJ45 - page 10

    10 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 NOZZLE (RJ45) 1. Remove upper shell (see Upper Shell Removal , page 8). 2. Remove fan (see Fa n , page 8). 3. Remove fuel and air line hoses from nozzle adapter . 4. T urn nozzle adapter 1/4 turn to left and pull toward motor to remove. 5 . Place nozzle adapter into vise and lightly tighten. 6 ...

  • Desa RJ45 - page 11

    11 104950 OWNER’S MANUAL Sandpaper Figure 22 - Sanding Rotor Figure 21 - Gap Adjusting Screw Locations Figure 20 - Rotor Location O TOR PFA/P 056 Insert Rotor Air Output Filter Blade Pump Plate Air Intake Filter Filter End Cover Fan Guard 0.08/0.10 mm Gap Measured With Feeler Gauge Blade Rotor Gap Adjusting Screw Gap Adjusting Screw SER VICE PROC ...

  • Desa RJ45 - page 12

    12 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 Figure 23- Wiring Diagram For RJ70 WIRING DIAGRAMS Figure 22- Wiring Diagram For RJ45 White Photo- cell Black Blue Flame- Out Control B Reset Button R Red Blue White Spark Plug Green/ Yellow Black Power Plug 100V/50 or 60 Hz Green White White White Red Green Terminal Board Ignitor Plug Receptac ...

  • Desa RJ45 - page 13

    13 104950 OWNER’S MANUAL ACCESSORIES Purchase accessories and parts from your nearest dealer. AIR GAUGE KIT - HA1180 Special tool to check pump pressure. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. A 008 IGNITION CONTROL ASSEMBLY/PHOTOCELL TESTER - HA1170 Special tool ...

  • Desa RJ45 - page 14

    14 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 9-1 9-2 9-3 9-4 9-5 17 18 19 20 21 22 23 24 25 26 27 28 29 30 34 35 36 32 38 33 31 42 41 40 39 37 ILLUSTRA TED P ARTS BREAKDOWN RJ45 Motor and Pump Assembly 12-1 12-2 12-18 12-4 12-3 12-17 12-16 12-5 12-6 12-15 12-8 12-9 12-10 12-7 12-14 12-13 12-11 12-12 ...

  • Desa RJ45 - page 15

    15 104950 OWNER’S MANUAL P ARTS LIST RJ45 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-36 Upper Shell 1 3 M11 ...

  • Desa RJ45 - page 16

    16 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 ILLUSTRA TED P AR TS BREAKDOWN RJ70 40 41 43 5 47 46 2 4 3 6 7 8 10 11 12 12 14 18 21 22 24 27 28 29 30 31 32 34 38 37 19 13 9 33 35 36 42 39 23 44 45 1 26 15 17 20 16 25 48 10-1 18-1 18-18 18-2 18-3 18-4 18-17 18-16 18-15 18-14 18-7 18-6 18-5 18-8 18-9 18-10 18-11 18-12 18-13 Motor and Pump As ...

  • Desa RJ45 - page 17

    17 104950 OWNER’S MANUAL P ARTS LIST RJ70 ∆ Not available as an assembly ** Included in Rotor Kit (Part No. HA3004) ⊕ Included in Filter Kit (Part No. HA3014) ∞ Included in Pump Adjustment Kit (Part No. HA3020) KEY PART PART NO. NUMBER DESCRIPTION QTY. 18-17 M8643** Blade 4 18-18 FHPF3-5C Screw, #10-32 x 5/8" 2 19 M50050 Rubber Cap 1 2 ...

  • Desa RJ45 - page 18

    W ARRANTY AND REP AIR SER VICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workman- ship. If so, DESA International will repair or replace the heater without c ...

Produzent Desa Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Desa RJ45 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Desa
- Bedienungsanleitungen RJ45
- Produktkarten Desa
- Informationsbroschüren
- oder Energieetiketten Desa RJ45
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Desa RJ45.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Desa RJ45, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Desa RJ45. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Desa RJ45 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Desa RJ45, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Desa RJ45 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Desa RJ45 verständlich ist.

Eine gänzliche Bedienungsanleitung von Desa sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Desa RJ45 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Desa RJ45 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Desa RJ45, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Desa RJ45 - die uns die ersten Schritte während der Nutzung von Desa RJ45 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Desa RJ45 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Desa RJ45 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Desa RJ45?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Desa RJ45 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Desa RJ45 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen