    POR T ABLE FORCED AIR HEA TER OWNER’S MANUAL IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. Heater Sizes: RJ45 And RJ70 ...

  • Desa RJ45 - page 2

    2 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater . Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the ? ...

  • Desa RJ45 - page 3

    3 104950 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - RJ45 Handle Fuel Cap Lower Shell Power Cord Fuel Tank Hot Air Outlet Air Filter End Cover Fan Guard Upper Shell Side Cover Ignition Control Assembly (assembly on inside of side cover) Handle Fuel Cap Lower Shell Power Cord Fuel Tank Hot Air Outlet Air Filter End Cover Fan Guard Upper Shel ...

  • Desa RJ45 - page 4

    4 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 Figure 3 - Cross Section Operational View Fuel Filter Air Line To Burner Air Output Filter Air Pump Air Intake Filter Cool Air In Fan Combustion Chamber Ignitor or Spark Plug Motor Clean Heated Air Out Ignition Control Assembly or Electronic Ignitor Air For Fuel System Air For Combustion And Hea ...

  • Desa RJ45 - page 5

    5 104950 OWNER’S MANUAL Item Fuel tank Air output and lint filters Air intake filter Fuel filter RJ45: Ignitor RJ70: Spark Plug Fan blades Motor WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. STORING, TRANSPOR TING, OR SHIPPING Note: If shipping, transport companies re- qui ...

  • Desa RJ45 - page 6

    6 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 TROUBLESHOOTING RJ45 WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. REMEDY 1. Check circuit breaker in electrical panel 2. Check all electrical connections. See W iring Diag rams, page 12 3. If fan does not turn freely , see ...

  • Desa RJ45 - page 7

    7 104950 OWNER’S MANUAL TROUBLESHOOTING Continued RJ70 WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. OBSERVED FAULT Heater ignites, but flame-out control shuts off heater after a short period of time Heater will not ignite, but motor runs for a short period of time Motor does ...

  • Desa RJ45 - page 8

    8 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 PUMP PRESSURE ADJUSTMENT 1. Remove pressure gauge plug from filter end cover . 2. Install accessory pressure gauge (part number HA1 180). 3. Start heater (see Opera tion , page 5). Al- low motor to reach full speed. 4. Using a flat blade screwdriver , adjust pressure. T urn relief valve to righ ...

  • Desa RJ45 - page 9

    9 104950 OWNER’S MANUAL Fuel Filter Side Cover Upper Fuel Line Figure 9 - Fuel Filter Removal FUEL FILTER 1. Remove side cover screws using 5/16" nut-driver (see Figure 9). 2. Remove side cover . 3. Pull upper fuel line off fuel filter neck. 4. Carefully pry bushing and fuel filter out of fuel tank. 5. W ash fuel filter with clean fuel an ...

  • Desa RJ45 - page 10

    10 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 NOZZLE (RJ45) 1. Remove upper shell (see Upper Shell Removal , page 8). 2. Remove fan (see Fa n , page 8). 3. Remove fuel and air line hoses from nozzle adapter . 4. T urn nozzle adapter 1/4 turn to left and pull toward motor to remove. 5 . Place nozzle adapter into vise and lightly tighten. 6 ...

  • Desa RJ45 - page 11

    11 104950 OWNER’S MANUAL Sandpaper Figure 22 - Sanding Rotor Figure 21 - Gap Adjusting Screw Locations Figure 20 - Rotor Location O TOR PFA/P 056 Insert Rotor Air Output Filter Blade Pump Plate Air Intake Filter Filter End Cover Fan Guard 0.08/0.10 mm Gap Measured With Feeler Gauge Blade Rotor Gap Adjusting Screw Gap Adjusting Screw SER VICE PROC ...

  • Desa RJ45 - page 12

    12 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 Figure 23- Wiring Diagram For RJ70 WIRING DIAGRAMS Figure 22- Wiring Diagram For RJ45 White Photo- cell Black Blue Flame- Out Control B Reset Button R Red Blue White Spark Plug Green/ Yellow Black Power Plug 100V/50 or 60 Hz Green White White White Red Green Terminal Board Ignitor Plug Receptac ...

  • Desa RJ45 - page 13

    13 104950 OWNER’S MANUAL ACCESSORIES Purchase accessories and parts from your nearest dealer. AIR GAUGE KIT - HA1180 Special tool to check pump pressure. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. A 008 IGNITION CONTROL ASSEMBLY/PHOTOCELL TESTER - HA1170 Special tool ...

  • Desa RJ45 - page 14

    14 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 9-1 9-2 9-3 9-4 9-5 17 18 19 20 21 22 23 24 25 26 27 28 29 30 34 35 36 32 38 33 31 42 41 40 39 37 ILLUSTRA TED P ARTS BREAKDOWN RJ45 Motor and Pump Assembly 12-1 12-2 12-18 12-4 12-3 12-17 12-16 12-5 12-6 12-15 12-8 12-9 12-10 12-7 12-14 12-13 12-11 12-12 ...

  • Desa RJ45 - page 15

    15 104950 OWNER’S MANUAL P ARTS LIST RJ45 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-36 Upper Shell 1 3 M11 ...

  • Desa RJ45 - page 16

    16 104950 POR T ABLE FORCED AIR HEA TERS RJ45 And RJ70 ILLUSTRA TED P AR TS BREAKDOWN RJ70 40 41 43 5 47 46 2 4 3 6 7 8 10 11 12 12 14 18 21 22 24 27 28 29 30 31 32 34 38 37 19 13 9 33 35 36 42 39 23 44 45 1 26 15 17 20 16 25 48 10-1 18-1 18-18 18-2 18-3 18-4 18-17 18-16 18-15 18-14 18-7 18-6 18-5 18-8 18-9 18-10 18-11 18-12 18-13 Motor and Pump As ...

  • Desa RJ45 - page 17

    17 104950 OWNER’S MANUAL P ARTS LIST RJ70 ∆ Not available as an assembly ** Included in Rotor Kit (Part No. HA3004) ⊕ Included in Filter Kit (Part No. HA3014) ∞ Included in Pump Adjustment Kit (Part No. HA3020) KEY PART PART NO. NUMBER DESCRIPTION QTY. 18-17 M8643** Blade 4 18-18 FHPF3-5C Screw, #10-32 x 5/8" 2 19 M50050 Rubber Cap 1 2 ...

  • Desa RJ45 - page 18

    W ARRANTY AND REP AIR SER VICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workman- ship. If so, DESA International will repair or replace the heater without c ...

Fabbricante Desa Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoDesa RJ45 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Desa
- manuali per l’uso RJ45
- schede prodotto Desa
- opuscoli
- o etichette energetiche Desa RJ45
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Desa RJ45.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Desa RJ45, manuali di manutenzione, brevi manuali o manuali utente Desa RJ45. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Desa RJ45.

Manuali per l’uso simili

Manuale completo del dispositivo Desa RJ45, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Desa RJ45 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Desa RJ45.

Il manuale per l’uso completo Desa, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Desa RJ45 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Desa RJ45, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Desa RJ45 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Desa RJ45 - che ci dovrebbe aiutare nei primi passi durante l'uso Desa RJ45
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Desa RJ45
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Desa RJ45 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Desa RJ45?

Utilizza il modulo sottostante

Se non hai risolto il problema con Desa RJ45 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Desa RJ45 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)