Bedienungsanleitung Bryant 213A

32 Seiten 0.91 mb
Download

Zur Seite of 32

Summary
  • Bryant 213A - page 1

    Pr oduct Dat a Model 213A Lega cy t -- RNC S erie s Heat Pump wit h Puron r Refrigerant Si zes 018 to 060 1 - - 1 / 2 To 5 N o m i n a l To n s Fig. 1 – 213A Brya nt’ s heat pum ps wit h Puron r r efr iger ant provi de a col lec tion of features un match ed b y an y oth er family o f eq uip men t. Th e 213A ha s be en de si gned u tilizing B ry ...

  • Bryant 213A - page 2

    2 MODEL NUMBER NOMENCLA T URE 1 2 34 5 6 7 8 9 1 0 1 11 2 1 4 N N N A A/N N N N N A/N A/N N A 21 3 A N A 0 3 6 0 0 0 0 Pro duct Fa mi ly Tie r SEER Major Series Volt age V ariations Cooling Capaci ty Open Op en Open Minor Series 2=HP 1= Leg acy RNC 3=13 SEER A=P uron N= 208 - - - 230 - - - 1 or 208/230 - - - 1 A = Standard 0=Not Defi ned 0=Not Defi ...

  • Bryant 213A - page 3

    3 PHYS ICAL DA T A UNIT SIZE SER IES 018 - - - A 024 - - - A 030 - - - A 036 - - - A 042 - - - A 048 - - - A 060 - - - A Operat ing Weig ht (lb ) 146 162 203 207 246 263 279 Shippin g Weight (lb) 169 189 235 239 278 293 311 Compressor T ype Scroll REFRIGERAN T Puron ® (R - - - 410A) Cont rol TXV (Puro n Hard Shutoff) Charge ( lb) 5.25 5.9 7.6 7.65 ...

  • Bryant 213A - page 4

    4 ACCESSO RIES ORDER NUM BER DES CRIPT ION 018 - - - A 024 - - - A 030 - - - A 036 - - - A 042 - - - A 048 - - - A 060 - - - A HC34GE239 BALL BEARING M O TOR X HC34GE240 BALL BEARING M O TOR X X HC38GE228 BALL BEARING M O TOR X HC40GE226 BALL BEARING M O TOR X HC40GE228 BALL BEARING M O TOR X X KAACH1201AAA C RANKCASE HTR X S S KAACH1401AAA C RANKC ...

  • Bryant 213A - page 5

    5 ACCESSO R Y USAGE GUIDELINE ACCESSORY RE QUIRED F OR LOW - - - AMBIE NT COOLING A PPLICATIONS (Below 55 ° F) REQUI RED FOR LONG LINE APPLICATIONS* (Over 80 F t.) REQUI RED FOR SEA COA ST APPLICATIONS (Within 2 miles) Crankc ase Heat er Ye s Ye s No Evap orator F reeze Therm ost at Ye s No No Accum ulator Stan dar d Stand ard Sta nda rd Compresso ...

  • Bryant 213A - page 6

    6 Accesso ry Descrip tion an d Usag e (Listed A lph ab etical ly) - - CO NTI NUED 10. Outdoor A ir T empe rat ure Se nsor De si gne d for use wi th Brya nt Ther mosta ts l ist ed in t his publi cat ion. This de vice e nable s the ther mosta t to displ ay the outdoor te mper at ure. This devi ce al so is re quir ed to ena ble special th ermo stat fe ...

  • Bryant 213A - page 7

    7 ELECTRICAL DA T A UNI T SIZ E V/P H OPER VOL TS* CO MPR FAN MCA MIN WIRE SIZE { MIN WIRE SIZE { MAX LENGTH (ft.) } MAX LENGTH (ft.) } MAX FUSE** or CK T BRK AMPS MAX MIN LRA RLA FLA 60 ° C 75 ° C 60 ° C 75 ° C 018 - - - A 208 - - - 230/1 253 197 48 9.0 0.75 12 14 14 66 62 20 024 - - - A 58.3 12.8 0.75 16.8 14 14 47 45 25 030 - - - A 77 14.1 0 ...

  • Bryant 213A - page 8

    8 DIMENSIONS 213A ...

  • Bryant 213A - page 9

    9 213ANA BALANCE POINT WORKSHEET 0 10 20 30 40 50 60 70 80 - - 1 0 0 1 02 03 04 05 06 07 08 0 OUTDOOR TEMPERA TURE , ºF BUILDI NG HEA T LOSS, UNIT I NTEGRA TED HEA TI NG CAP ACI TY , MBTUH 0.0 2.9 5.9 8.8 11 . 7 14.6 17.6 20.5 23.4 kW 213ANA024A FY4A NF024 213RNA030A FY4A NF030 213RNA036A FY4A NF042 A05007 213ANA042A FY4A NF042 213ANA060A FY4A NB0 ...

  • Bryant 213A - page 10

    10 COMBINA TION RA TINGS Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 018 - - - A *FY4ANF018 17,100 TDR&TXV 13.00 10.50 18,000 3.36 10,900 2.24 7.7 FF1ENP018 17,100 TDR&TX ...

  • Bryant 213A - page 11

    11 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 024 - - - A CNPH*2417A** 22,800 TDR&TXV 14.00 11.60 23,600 3.72 14,400 2.62 8.5 315(A,J)AV04809 ...

  • Bryant 213A - page 12

    12 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 030 - - - A FX4CNF030 29,600 TDR&TXV 14.00 10.80 31,400 3.60 21,000 2.66 8.5 FY4ANF036 29,600 T ...

  • Bryant 213A - page 13

    13 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 030 - - - A CSPH*3012A* * 29,200 TDR&TXV 14.00 11.00 30,800 3.50 20,600 2.64 8.3 315(A, J)AV066 ...

  • Bryant 213A - page 14

    14 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 036 - - - A CNPH*3617A** 33,400 TXV 13.00 10.50 35,600 3.44 22,000 2.38 7.9 CNPH*4221A** 33,600 TDR ...

  • Bryant 213A - page 15

    15 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 042 - - - A CAP**4221A** 40,000 TDR&TXV 14.00 11.20 41,000 3.50 25,200 2.52 8.1 315(A,J)AV06011 ...

  • Bryant 213A - page 16

    16 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 042 - - - A CNPV*4824A** 40,500 TDR&TXV 13.50 11.20 41,000 3.60 25,400 2.52 8.2 355AAV042040 CN ...

  • Bryant 213A - page 17

    17 COMBINA TION RA TINGS CONTINUED Unit S i z e --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Fur na ce M od el Fac to ry Enhance Standard Rating SEER TDR EER High T emp Low T emp HSPF E Capacity E COP H Capacity H COP 048 - - - A CNPH*4821A** 45,000 TXV 13.00 10.80 49,000 3.68 30,400 2.60 8.4 CNPH*6024A** 46,500 TDR ...

  • Bryant 213A - page 18

    18 DET AILED COOLING CAP ACITIES EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * T ...

  • Bryant 213A - page 19

    19 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 20

    20 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 21

    21 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 22

    22 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 23

    23 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 24

    24 DET AILED COOLING CAP ACITIES CONTINUED EVAPORA TOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal System KW* * Capacity MBtuh† T otal Syste ...

  • Bryant 213A - page 25

    25 HEA T PUMP HEA TING PERFORMANCE INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- ...

  • Bryant 213A - page 26

    26 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 27

    27 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 28

    28 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 29

    29 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 30

    30 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 31

    31 HEA T PUMP HEA TING PERFORMANCE CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMP ERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t a l Sys- tem KW† Capacity MBtuh To t ...

  • Bryant 213A - page 32

    32 GUIDE SPECIFICA TIONS GENERAL System Description Outdoor- - mounted, air- -cooled, split - -system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor , an air - - cooled coil, propeller - -type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Un ...

Produzent Bryant Kategorie Heat Pump

Dokumente, die wir vom Produzenten des Geräts Bryant 213A erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Bryant
- Bedienungsanleitungen 213A
- Produktkarten Bryant
- Informationsbroschüren
- oder Energieetiketten Bryant 213A
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Bryant 213A.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Bryant 213A, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Bryant 213A. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Bryant 213A ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Bryant 213A, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Bryant 213A hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Bryant 213A verständlich ist.

Eine gänzliche Bedienungsanleitung von Bryant sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Bryant 213A bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Bryant 213A befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Bryant 213A, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Bryant 213A - die uns die ersten Schritte während der Nutzung von Bryant 213A erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Bryant 213A hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Bryant 213A im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Bryant 213A?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Bryant 213A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Bryant 213A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)