Bedienungsanleitung ADTRAN AHDSL2

30 Seiten 0.29 mb
Download

Zur Seite of 30

Summary
  • ADTRAN AHDSL2 - page 1

    61221002L2-5B 1 ADTRAN ® AHDSL2 Asynchronous H2TU-C Line Card for Alcatel Litespan ® Channel Bank Assemblies Using Narrowband Pairs Installation and Maintenance Practice Section 61221002L2-5B Issue 2, August 2003 CLEI Code: SLL5R3DG_ _ CONTENTS 1. General ......................................................................... 1 2. Applications ...

  • ADTRAN AHDSL2 - page 2

    2 61221002L2-5B Table 1 lists and defines the H2TU-C Front Panel LED indicators. Each ADTRAN Litespan H2TU-C line card provides a 1.552 kbps data transport over one unconditioned CSA copper pair. These CSA loops can range up to 12 kft of 24-AWG twisted pair wire. The Litespan H2TU-C can be used in Litespan 2000, Litespan 2012, and Litespan ONU chan ...

  • ADTRAN AHDSL2 - page 3

    61221002L2-5B 3 2. APPLICATIONS The ADTRAN HDSL2 system provides a cost-effective alternative for deploying T1 service over metallic cable pairs. In contrast with traditional T1 service equipment, ADTRAN HDSL2 can be successfully deployed over one unconditioned, nonloaded, bridged-tapped copper pair CSA loop (see Deployment Guidelines , Section 4). ...

  • ADTRAN AHDSL2 - page 4

    4 61221002L2-5B CAUTION Prior to installing or removing the Litespan H2TU-C, observe the following warning: If the Litespan H2TU-C is removed from a line card slot, wait at least 15 seconds before reinsertion. If connected to the MTI craft interface terminal, wait until the message “AID:MJ,UEQ.” appears (where “AID” is the access identifier ...

  • ADTRAN AHDSL2 - page 5

    61221002L2-5B 5 Provisioning Commands Upon initial insertion of the Litespan H2TU-C into the Litespan system, configuration options are downloaded automatically to the line card and take precedence over the ADTRAN default provisioning options. NOTE The provisioning options stored in the shelf controller can be pre-configured by the user through the ...

  • ADTRAN AHDSL2 - page 6

    6 61221002L2-5B 1 L T s d n a m m o C t f a r c e t i L s r e t e m a r a P C - U T 2 H s n o i t p O C - U T 2 H s g n i t t e S e l b a l i a v A g n i d n o p s e r r o C s g n i t t e S t f a r c e t i L e l b a r u g i f n o C - e r P e u l a V L S D H - D EK B P L D I Nk c a b p o o L U I Nd e l b a s i D d e l b a n E O N S E Y S E Y L S D H ...

  • ADTRAN AHDSL2 - page 7

    61221002L2-5B 7 Testing Commands The H2TU-C testing commands are used to initiate and terminate loopbacks and disconnect for testing purposes. Table 8 lists and defines the TL1/Litecraft testing commands. NOTE Before entering loopbacks, the user needs to remove the card from service. This can be done with the RMV-HDSL command. The card can then be ...

  • ADTRAN AHDSL2 - page 8

    8 61221002L2-5B Figure 4. Deployment Guidelines Table 9 lists the ADTRAN Litespan H2TU-C and H2TU-R factors needed to calculate channel bank power using Worksheet PW-1. The Table 9 power factors are derived from the power parameters listed in Table 10 . 4. DEPLOYMENT GUIDELINES The ADTRAN HDSL2 system is designed to provide DS1-based services over ...

  • ADTRAN AHDSL2 - page 9

    61221002L2-5B 9 Loop loss per kft for other wire is summarized in Table 11 . Cable Gauge 26 26 24 24 22 22 19 19 Cable Type PIC Pulp PIC Pulp PIC Pulp PIC Pulp Temperature ( ° F) 68 ° 90 ° 120 ° 3.902 4.051 4.253 4.030 4.179 4.381 2.863 2.957 3.083 3.159 3.257 3.391 2.198 2.255 2.333 2.483 2.450 2.629 1.551 1.587 1.634 1.817 1.856 1.909 Table 1 ...

  • ADTRAN AHDSL2 - page 10

    10 61221002L2-5B Table 13. Troubleshooting Guide Condition At power up, all front panel indicators are OFF The STAT LED remains RED. The STAT LED is OFF, but the HLOS LED remains RED . The STAT LED is OFF, but the RLOS LED remains RED. Solution 1. Verify that the channel bank or ONU BPS power LEDs are on. 2. Make sure that the unit is fully and cor ...

  • ADTRAN AHDSL2 - page 11

    61221002L2-5B 11 Table 14. ADTRAN H2TU-C Specifications Loop Interface Modulation Type ............................................... 16 TC PAM Mode .................................................................. Full duplex, partially overlapped echo canceling Number of Pairs ................................................ One Line Rate ..... ...

  • ADTRAN AHDSL2 - page 12

    12 61221002L2-5B This page is intentionally blank. ...

  • ADTRAN AHDSL2 - page 13

    61221002L2-5B A-1 HDSL MAINTENANCE MODES This appendix describes operation of the HDSL2 system with regard to detection of in-band and ESF facility data link loopback codes. Upon deactivation of a loopback, the HDSL2 system will synchronize automatically. Loopback Process Description In general, the loopback process for the HDSL2 system elements is ...

  • ADTRAN AHDSL2 - page 14

    A-2 61221002L2-5B Table A-1. In-Band Addressable Loopback Codes n o i t c n u Fe d o Ce s n o p s e R 3 n i 1 1 0 0 1. g n i h t y r e v e n w o d p o o L 6 n i 1 1 0 0 0 0 0 1 e r o f e b d e m r a e b t s u m ; k r o w t e n e h t d r a w o t R - U T 2 H e h t t a k c a b p o o L . d e t a i t i n i 7 n i 40 0 0 1 1 1 1 . C - U T 2 H e h t n i k ...

  • ADTRAN AHDSL2 - page 15

    61221002L2-5B A-3 n o i t c n u Fe d o Ce s n o p s e R n w o d p o o L 3 , 1 3 9 3 9 1 0 0 1 1 1 0 0 1 0 0 1 1 1 0 0 k c a b p o o l n i y l t n e r r u c s t i n u l l a , r e m o t s u c r o k r o w t e n e h t m o r f t n e s n e h W a e k i l e v a h e b o t r e d r o n I . m r a s i d t o n l l i w s t i n u d e m r A . n w o d p o o l l l i ...

  • ADTRAN AHDSL2 - page 16

    A-4 61221002L2-5B This page is intentionally blank. ...

  • ADTRAN AHDSL2 - page 17

    61221002L2-5B B-1 Appendix B TL1 H2TU-C T utorial GENERAL This appendix is intended to highlight the necessary menus/commands needed to provision the ADTRAN H2TU-C card. A more detailed explanation of shelf specific items may be found in the Alcatel TL1 Reference Practice, OSP-363-205-502. Logging into the TL1 command screens is accomplished by ent ...

  • ADTRAN AHDSL2 - page 18

    B-2 61221002L2-5B MAINTENANCE MENU AND ASSOCIATED SUB-MENUS From the Main Menu, enter “2” to display the Maintenance Menu as shown below. Maintenance Menu 1. ADSL Maintenance Menu 2. ATM Maintenance Menu 3. EC1 Maintenance Menu 4. Equipment Maintenance Menu 5. External Controls Menu 6. HDSL Maintenance Menu ← ← ← ← ← Item of interest ...

  • ADTRAN AHDSL2 - page 19

    61221002L2-5B B-3 HDSL MAINTENANCE MENU From the Maintenance Menu, enter “6” to display the HDSL Maintenance Menu as shown below. HDSL Maintenance Menu 1. ALW-MSG-HDSL 2. INH-MSG-HDSL 3. RMV-HDSL 4. RST-HDSL 5. RTRV-ALM-HDSL ← ← ← ← ← Retrieve existing HDSL alarms for the H2TU-C 6. RTRV-ATTR-HDSL 7. RTRV-COND-HDSL 8. SET-ATTR-HDSL B. ...

  • ADTRAN AHDSL2 - page 20

    B-4 61221002L2-5B T1 MAINTENANCE MENU From the Maintenance Menu, enter “20” to display the T1 Maintenance Menu as shown below. T1 Maintenance Menu 1. ALW-MSG-T1 2. ALW-SW-T1 3. CONN-JACK-T1 4. DISC-JACK-T1 5. INIT-REG-T1 ← ← ← ← ← Clears the T1 PM data for the H2TU-C 6. INH-MSG-T1 7. INH-SW-T1 8. OPR-PROTNSW-T1 9. RLS-PROTNSW-T1 10. R ...

  • ADTRAN AHDSL2 - page 21

    61221002L2-5B B-5 PROVISIONING MENU From the Main Menu, enter “3” to display the Provisioning Menu as shown below. Provisioning Menu 1. ADSL Provisioning Menu 2. Cross-Connection Menu ← ← ← ← ← Item of interest for the H2TU-C 3. EC1 Provisioning Menu 4. Equipment Provisioning Menu 5. Ethernet Provisioning Menu 6. HDSL Provisioning Men ...

  • ADTRAN AHDSL2 - page 22

    B-6 61221002L2-5B CROSS-CONNECTION MENU From the Provisioning Menu, enter “2” to display the Cross-Connection Menu as shown below. Cross-Connection Menu 1. DLT-CRS-STS1 2. DLT-CRS-T0 3. DLT-CRS-T1 ← ← ← ← ← Delete an existing cross-connect 4. DLT-CRS-T3 5. DLT-CRS-VC 6. DLT-CRS-VP 7. ED-CRS-STS1 8. ED-CRS-T0 9. ED-CRS-T3 10. ENT-CRS-S ...

  • ADTRAN AHDSL2 - page 23

    61221002L2-5B B-7 ENT-CRS-T1 Command Input Format The choice to enter cross-connects may be accomplished either by selecting “12” from the Cross-Connection Menu or by entering the command directly as shown in the example below where a cross-connect is initiated between slot 1 and slot 21. <ENT-CRS-T1 FROM[]= RT-1-1 TO[]= RT-1-21. or <ENT- ...

  • ADTRAN AHDSL2 - page 24

    B-8 61221002L2-5B HDSL PROVISIONING MENU From the Provisioning Menu, enter “6” to display the HDSL Provisioning Menu as shown below. HDSL Provisioning Menu 1. DLT-HDSL 2. ED-HDSL ← ← ← ← ← Edit HDSL provisioning parameters for the H2TU-C 3. ENT-HDSL 4. RTRV-HDSL 5. DLT-GOS-HDSL 6. ED-GOS-HDSL ← ← ← ← ← Edit the HDSL Grade of ...

  • ADTRAN AHDSL2 - page 25

    61221002L2-5B B-9 <ED-HDSL LPBKACTR[]={0000000000000000 | 0000000000000001}; or <ED-HDSL::RT-1-21:::: LPBKACTR ={0000000000000000 | 0000000000000001}; <ED-HDSL LPBKDEACTCDE[]={0000000000000000 | 0000000000000001 | 0000000000000010}; or <ED-HDSL::RT-1-21:::: LPBKDEACTCDE ={0000000000000000 | 0000000000000001 | 0000000000000010}; <ED-H ...

  • ADTRAN AHDSL2 - page 26

    B-10 61221002L2-5B Grade of Service tables allow the user to set performance monitoring threshold levels for various alarms/event conditions. There are 15 GOS tables available for each type of service (in our case T1 and HDSL). Example: The HDSL GOS1 may contain a loop attenuation threshold setting of 30 (dB) while HDSL GOS2 contains a loop attenua ...

  • ADTRAN AHDSL2 - page 27

    61221002L2-5B B-11 <ED-T1 FMT[]={ESF | SF | UNFR | AUTO}; or <ED-T1::RT-1-21::::FMT={ESF | SF | UNFR | AUTO}; <ED-T1 LINECDE[]= {AMI | B8ZS}; or <ED-T1::RT-1-21::::LINECDE={AMI | B8ZS}; TESTING MENU From the Main Menu, enter “4” to display the Testing Menu as shown below. Testing Menu 1. OPR-LPBK-HDSL ← ← ← ← ← Enable a lo ...

  • ADTRAN AHDSL2 - page 28

    B-12 61221002L2-5B NOTE Prior to entering any loopback command, the line card must be removed from service. Remove card from service = RMV-HDSL; H2TU-C Network Loopback Loop up command = OPR-LPBK-HDSL::RT-1-21-C:::NEND; Loop down command = RLS-LPBK-HDSL::RT-1-21-C:::NEND; H2TU-C Customer Loopback Loop up command = OPR-LPBK-HDSL::RT-1-21-C:::FEND; L ...

  • ADTRAN AHDSL2 - page 29

    61221002L2-5B C-1 This appendix describes the testing functionality available for the ADTRAN H2TU-C card via the MTAU unit. For a complete description of the MTAU unit refer to Alcatel document Common Equipment Unit Descriptions , OSP 363-405-250. NOTE The functionality of the SPLIT and MON features detailed in this document supercedes that shown i ...

  • ADTRAN AHDSL2 - page 30

    C-2 61221002L2-5B Figure C-2 . MON Mode HDSL2 T ransceiver AHDSL2 T est LIU Tip A-3 HDSL2 Loop Ring1 A-4 T AE, RAE EQPT jacks on the MT A U TBE, RBE Alcatel Network Equip MON Mode Used to test tow ard the remote customer equipment REMOVAL OF MTAU TEST ACCESS DISC-JACK-T1 The Disconnect T1 Jack command disconnects a T1 or HDSL facility from the meta ...

Produzent ADTRAN Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts ADTRAN AHDSL2 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen ADTRAN
- Bedienungsanleitungen AHDSL2
- Produktkarten ADTRAN
- Informationsbroschüren
- oder Energieetiketten ADTRAN AHDSL2
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung ADTRAN AHDSL2.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen ADTRAN AHDSL2, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen ADTRAN AHDSL2. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts ADTRAN AHDSL2 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts ADTRAN AHDSL2, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von ADTRAN AHDSL2 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von ADTRAN AHDSL2 verständlich ist.

Eine gänzliche Bedienungsanleitung von ADTRAN sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von ADTRAN AHDSL2 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von ADTRAN AHDSL2 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich ADTRAN AHDSL2, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts ADTRAN AHDSL2 - die uns die ersten Schritte während der Nutzung von ADTRAN AHDSL2 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit ADTRAN AHDSL2 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von ADTRAN AHDSL2 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich ADTRAN AHDSL2?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit ADTRAN AHDSL2 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit ADTRAN AHDSL2 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)