    Fiberglass Cooling Towers Part Number: 882.00440.00 Bulletin Number: SC6-610.6 Effective: 9/10/07 Write Down Your Serial Numbers Here For Future Reference: _________________________ _________________________ _________________________ _________________________ _________________________ _________________________ We are committed to a continuing progr ...

  • Sterling 882.00440.00 SC6-610.6 - page 2

    Fiberglass Cooling Towers ii Shipping Information Unpacking and Inspection You should inspect your equipm ent for possible shipping damage. Thoroughly check the equipment for any damage that m ight have occu rred in transit, such as broken or loose wiring and components, loose hardware and mounting screws, etc. In the Event of Shipping Damage Accor ...

  • Sterling 882.00440.00 SC6-610.6 - page 3

    Fiberglass Cooling Towers iii Table of Contents CHAPTER 1: SAFETY ................................................................ 6 1-1 How to Use Th is M anual ................................................................................. 6 Safety Symbols Used in this Manual ..................................................................... ...

  • Sterling 882.00440.00 SC6-610.6 - page 4

    Fiberglass Cooling Towers iv 6-3 Parts Li st ....................................................................................................... 24 6-4 Electrical Sc hematic s .................................................................................... 25 ...

  • Sterling 882.00440.00 SC6-610.6 - page 5

    Fiberglass Cooling Towers v List of Figures Figure 1: Structural Stee l Support Requirements ......................................................................... 11 Figure 2: Rigging Arrangement .................................................................................................. .. 13 Figure 3: Cooling Tower with To wer Reservoir ...

  • Sterling 882.00440.00 SC6-610.6 - page 6

    Fiberglass Cooling Towers Chapter 1: Safety Page 6 of 25 Chapter 1: Safety 1-1 How to Use This Manual Use this manual as a guide and reference for installing, operating, and maintaining your equipment. The purpose is to assist you in a pplying efficient, proven techniques that enhance equipment productivity. This manual covers only light corrective ...

  • Sterling 882.00440.00 SC6-610.6 - page 7

    Fiberglass Cooling Towers Chapter 1: Safety Page 7 of 25 1-2 Warnings and Precautions Our equipment is designed to provide safe and reliable operation when installed and operated within design specifications, following national and local safety codes. To avoid possible personal injury or equi pm ent damage when installing, operating, or maintaining ...

  • Sterling 882.00440.00 SC6-610.6 - page 8

    Fiberglass Cooling Towers Chapter 2: Functional Description Page 8 of 25 Chapter 2: Functional Description 2-1 Models Covered in This Manual This manual covers fiberglass cooling tower m odels. Model numbers are listed on the serial tag. A model number followed by –Q is specially-constructed, and the information in this manual may not apply. Make ...

  • Sterling 882.00440.00 SC6-610.6 - page 9

    Fiberglass Cooling Towers Chapter 2: Functional Description Page 9 of 25 2-4 Optional Features Side Outlet. The side outlet is used when th e tower basin is used as a reservoir. Starter Package. The starter package includes a st arter, a re mote On/Off switc h, a thermostat, and a well. Basin Reservoir. The basin reservoir includes an automatic flo ...

  • Sterling 882.00440.00 SC6-610.6 - page 10

    Fiberglass Cooling Towers Chapter 3: Installation Page 10 of 25 Chapter 3: Inst allation 3-1 Tower Installation Location Roof Installation Select a location over or nearest to the heavi est building structural members. These members should be outside load-bearing walls, building co l umns, or roof joists. You may need to spread the load over severa ...

  • Sterling 882.00440.00 SC6-610.6 - page 11

    Fiberglass Cooling Towers Chapter 3: Installation Page 11 of 25 Figure 1: Structural St eel Support Requirements TSE50 Structural steel A C C B B C C D 2 X 2 angle to support tower basin, flush with top of structural steel rails Model A B C D number in. cm in. cm in. cm in. cm SF2003 52 132.1 50 127.0 16 40.6 78 175.3 SF2004 52 132.1 50 127.0 16 40 ...

  • Sterling 882.00440.00 SC6-610.6 - page 12

    Fiberglass Cooling Towers Chapter 3: Installation Page 12 of 25 3-2 Assembling the Cooling Tower in the Field Your cooling tower may have been shipped on two skids to reduce shipping charges. One skid contains the lower section, identifie d by the black fill wrapped in plastic on the inside of the lower section. The second skid contains the top tow ...

  • Sterling 882.00440.00 SC6-610.6 - page 13

    Fiberglass Cooling Towers Chapter 3: Installation Page 13 of 25 Do not let the rigging transfer any load to the cooling tower shell. Provide support to the bottom of the cooling tower when riggi ng. Do not rig from the corners of the o p tional base. Do not ri g less than 8 inches from the corners. 3-3 Rigging Handle the fiberglass cooling tower sh ...

  • Sterling 882.00440.00 SC6-610.6 - page 14

    Fiberglass Cooling Towers Chapter 3: Installation Page 14 of 25 Install the piping according to the piping diagra ms in Figure 3 on page 14, Figure 4 on page 14, and Figure 5 on page 15. Figure 3: Cooling Tower with To wer Reservoir Piping Diagram inlet Type 2 Type 2 pressure gauge Do not apply excessive torque to fittings Caution! Overflow 3/4&quo ...

  • Sterling 882.00440.00 SC6-610.6 - page 15

    Fiberglass Cooling Towers Chapter 3: Installation Page 15 of 25 Figure 5: Flexible PVC Outlet Coupler Tower outlet Flexible PVC coupling (from AEC) Outlet pipe must be supported from building structure or tower steel Clamps (from AEC) (from Sterling) Flexible PVC Coupling (from Sterlin g ) ...

  • Sterling 882.00440.00 SC6-610.6 - page 16

    Fiberglass Cooling Towers Chapter 3: Installation Page 16 of 25 3-6 Setting Up the Water Balancing Valve Install the plug provided in the unused water in let on the side of the tower. Tighten and check for leaks. To prevent damage to the tower fill materi al, use the water throttling valve and pressure gauge to regulate the water pressure to the to ...

  • Sterling 882.00440.00 SC6-610.6 - page 17

    Fiberglass Cooling Towers Chapter 4: Operation Page 17 of 25 Chapter 4: Operation 4-1 Bleed-Off and Evaporation Rates A proper bleed-off rate is important to limit the concentration of minerals and foreign materials in re-circulated water. A bleed-off e qual to the evaporation rate, normally about two gallons per hour per ton (7. 57 liters per hour ...

  • Sterling 882.00440.00 SC6-610.6 - page 18

    Fiberglass Cooling Towers Chapter 5: Maintenance Page 18 of 25 Chapter 5: Maintenance 5-1 Preventative Maintenance Water Treatment Control of slime, algae, and bacteria growth is extremely important. Cooling towers and reservoir pump tanks are superb environments for microorganism growth. Warm water, organic debris, and air encourage bacterial grow ...

  • Sterling 882.00440.00 SC6-610.6 - page 19

    Fiberglass Cooling Towers Chapter 5: Maintenance Page 19 of 25 5-2 Corrective Maintenance Replacing Nozzles and Fill The PVC fill used in these cooling towers provides years of maintenance-free service under normal conditions. If you discover dirty water or defective nozzle(s) dama ge the fill, you can order a replacement kit from the parts departm ...

  • Sterling 882.00440.00 SC6-610.6 - page 20

    Fiberglass Cooling Towers Chapte r 6: Appendix Page 20 of 25 Chapter 6: Appendix 6-1 Technical Assistance Parts Department Call Toll-Free 7am–6pm CST [ 800 ] 423-3183 or call [ 262 ] 641-8 610 Our Parts Department is ready to provide th e parts to keep your s ystems up and running. OEM replacement parts ensure operation at d esign specifications. ...

  • Sterling 882.00440.00 SC6-610.6 - page 21

    Fiberglass Cooling Towers Chapte r 6: Appendix Page 21 of 25 6-2 Drawings and Specifications C A0536711 A Fan guard B Top View Access Fan motor Fan blade Nozzle adaptor Nozzle door Rigid PVC tower fill Water diverter Motor support assembly Side View Cutaway View Supply piping D Return pipin g E Figure 7: Dimensions and Weights Dimensions Weights Mo ...

  • Sterling 882.00440.00 SC6-610.6 - page 22

    Fiberglass Cooling Towers Chapte r 6: Appendix Page 22 of 25 Figure 8: Tower Performance c Cooling Fan NEC Nominal Model capacity Nozzles motor amp draw air flow number tons Kcal/hr no. hp kW rpm 460/3/60 cfm cmh SF2003 50 151,200 1 2 1.5 1,200 3.4 12,000 20,388 SF2004 75 226,800 4 5 3.7 1,200 7.6 18,000 30,582 SF2005 100 302,400 4 5 3.7 900 7.6 23 ...

  • Sterling 882.00440.00 SC6-610.6 - page 23

    Fiberglass Cooling Towers Chapte r 6: Appendix Page 23 of 25 Figure 9: Cooling Tower Nozzle Capacity ...

  • Sterling 882.00440.00 SC6-610.6 - page 24

    Fiberglass Cooling Towers Chapte r 6: Appendix Page 24 of 25 6-3 Parts List Figure 10: Supplied Parts for Field Assembly Part Number Quantity Description A0101485 1 Silicone A0533163 110 Stainless steel flat washers, 5/16” A0539417 55 Stainless steel screws, 5/16”-18 x 1 3/4” A0533167 55 Stainless steel hex nut, 5/16”-18 A0534122 55 Stainle ...

  • Sterling 882.00440.00 SC6-610.6 - page 25

    Fiberglass Cooling Towers Chapte r 6: Appendix Page 25 of 25 6-4 Electrical Schematics Figure 12: Typical Wiring Diagram 115/1/60 208-230-460/3/60 Starter with overloads M Fan ON/OFF switch Thermostat Immerse bulb in tank Non-fused disconnect at tower Fused disconnect switch ...

Produzent Sterling Kategorie Fan

Dokumente, die wir vom Produzenten des Geräts Sterling 882.00440.00 SC6-610.6 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Sterling
- Bedienungsanleitungen 882.00440.00 SC6-610.6
- Produktkarten Sterling
- Informationsbroschüren
- oder Energieetiketten Sterling 882.00440.00 SC6-610.6
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Sterling 882.00440.00 SC6-610.6.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Sterling 882.00440.00 SC6-610.6, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Sterling 882.00440.00 SC6-610.6. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Sterling 882.00440.00 SC6-610.6 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Sterling 882.00440.00 SC6-610.6, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Sterling 882.00440.00 SC6-610.6 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Sterling 882.00440.00 SC6-610.6 verständlich ist.

Eine gänzliche Bedienungsanleitung von Sterling sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Sterling 882.00440.00 SC6-610.6 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Sterling 882.00440.00 SC6-610.6 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Sterling 882.00440.00 SC6-610.6, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Sterling 882.00440.00 SC6-610.6 - die uns die ersten Schritte während der Nutzung von Sterling 882.00440.00 SC6-610.6 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Sterling 882.00440.00 SC6-610.6 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Sterling 882.00440.00 SC6-610.6 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Sterling 882.00440.00 SC6-610.6?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Sterling 882.00440.00 SC6-610.6 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Sterling 882.00440.00 SC6-610.6 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)