    LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor , this warranty will la ...

  • Emerson CF730 - page 2

    2 W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accident ...

  • Emerson CF730 - page 3

    3 This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing. Call T oll-Free: 1-800-654-3545 ! W ARNING This product is designed to use only those parts supplied with this product and/or any accessories designated specifica ...

  • Emerson CF730 - page 4

    4 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. T o reduce the risk of fire, electric shock, or personal injury , mount fan to outlet box marked “Acceptable for Fan Support”, and use s ...

  • Emerson CF730 - page 5

    5 3. Pass the outlet box supply wires (black, white and ground) through the center hole in the mounting plate and securely attach the mounting plate to the outlet box using the screws supplied with the outlet box (Figure 3). NOTE: In order for the fan housing to fit flush with the ceiling, the outlet box must not protrude below the ceiling. 4. Care ...

  • Emerson CF730 - page 6

    6 NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. 5. Refer to Figures 5 and 6 and connect the receiver wires to the supply wires and the fan motor wires as follows: a. Securely connect ...

  • Emerson CF730 - page 7

    9. Align the two indents on the inside of the motor housing with the two tabs on the mounting plate (Figure 8). T urn the housing clockwise to hold the housing on the mounting plate. Secure the housing to the mounting plate by installing four pointed M5 x 12mm pan head screws with lockwashers (supplied). 7 SW101 F AN/LIGHT WALL CONTROL (SUPPLIED) B ...

  • Emerson CF730 - page 8

    8 M5 x 6mm WASHER HEAD SCREWS (3) CAPTIVE SCREWS (2) BLADE FLANGE F AN BLADE Figure 9 10. Mount one blade flange to a fan blade using three M5 x 6mm washer head screws (supplied) (Figure 9). Repeat this procedure for the four remaining blades. CAPTIVE SCREWS (2) BLADE FLANGE MOTOR HUB Figure 10 SWITCH HOUSING BLUE WIRE LIGHT FITTER BLACK WIRE SWITC ...

  • Emerson CF730 - page 9

    9 18. Screw in two 60-watt (maximum) candelabra bulbs in the light fitter sockets (Figure 12). Bulbs not supplied. 19. Place the lower glass into the light fitter , aligning the three flat areas on the lower glass flange with the three tabs on the light fitter (Figure 13). Then turn the lower glass clockwise until the glass stops turning. 20. Y our ...

  • Emerson CF730 - page 10

    4. Install a wall control in the wall box containing the “hot” wire first. Connect the black wire of the wall control to the “hot” wire. Securely connect wires with wire connectors supplied. 5. Connect one black wire of the wall control to both remaining traveler wires in the wall box and secure with wire connector supplied. 4. Connect one ...

  • Emerson CF730 - page 11

    NOTE: Retrofit 3-way installations are likely to include two traveler wires between the two wall boxes. In new construction, only one traveler wire Is required. 3-WA Y WIRlNG DIAGRAM: NEW CONSTRUCTION 6. Place wall control into wall box. Screw in place and install decorator style faceplate (included). 7. Next, install the other wall control into th ...

  • Emerson CF730 - page 12

    12 Operating Y our Ceiling Fan IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Y our Fan/Light Wall Control (Figure 19) has full control of your fan and light. However , airflow direction is controlled by a pull chain on the light fitter switch. 1. Restore electrical ...

  • Emerson CF730 - page 13

    13 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING Maintenance IMPORT ANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed. When cleaning, use only a soft brush or lint free cl ...

  • Emerson CF730 - page 14

    Repair Parts 8 17 18 9 10 13 12 2 11 4 3 16 14 15 7 5 HI MED LOW FAN OFF LIGHT ON OFF EMERSON 1 6 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REP AIR P ARTS, AL W A YS GIVE THE FOLLOWING INFORMA TION: • P ART NUMBER • NAME OF ITEM • P ART DESCRIPTION • MODEL NUMBER ...

  • Emerson CF730 - page 15

    15 Part Numbers Key Model No. Model No. Model No. N o . Description CF730WB00 CF730BZH00 CF730AGW00 1 Plate, Mounting 763139 763139 763139 2 Housing, Fan 763126-WB 763126-BZH 763126-AGW 3 Flange Set (full set of one fan) 763127-WB 763127-BZH 763127-AGW 4 Blade Set (full set of one fan) 763132 763132-1 763132-1 5 Harness Assembly , Wiring 763134 763 ...

  • Emerson CF730 - page 16

    Part No. F40BP73150000 Printed in China 03/06 Form No. BP7315 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch circuit fuses start. blown. or circuit breakers. W ARNING: Make su ...

Produzent Emerson Kategorie Fan

Dokumente, die wir vom Produzenten des Geräts Emerson CF730 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Emerson
- Bedienungsanleitungen CF730
- Produktkarten Emerson
- Informationsbroschüren
- oder Energieetiketten Emerson CF730
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Emerson CF730.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Emerson CF730, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Emerson CF730. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Emerson CF730 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Emerson CF730, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Emerson CF730 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Emerson CF730 verständlich ist.

Eine gänzliche Bedienungsanleitung von Emerson sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Emerson CF730 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Emerson CF730 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Emerson CF730, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Emerson CF730 - die uns die ersten Schritte während der Nutzung von Emerson CF730 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Emerson CF730 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Emerson CF730 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Emerson CF730?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Emerson CF730 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Emerson CF730 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)