  • Emerson CF730 - page 1

    LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor , this warranty will la ...

  • Emerson CF730 - page 2

    2 W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accident ...

  • Emerson CF730 - page 3

    3 This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing. Call T oll-Free: 1-800-654-3545 ! W ARNING This product is designed to use only those parts supplied with this product and/or any accessories designated specifica ...

  • Emerson CF730 - page 4

    4 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds. T o reduce the risk of fire, electric shock, or personal injury , mount fan to outlet box marked “Acceptable for Fan Support”, and use s ...

  • Emerson CF730 - page 5

    5 3. Pass the outlet box supply wires (black, white and ground) through the center hole in the mounting plate and securely attach the mounting plate to the outlet box using the screws supplied with the outlet box (Figure 3). NOTE: In order for the fan housing to fit flush with the ceiling, the outlet box must not protrude below the ceiling. 4. Care ...

  • Emerson CF730 - page 6

    6 NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. 5. Refer to Figures 5 and 6 and connect the receiver wires to the supply wires and the fan motor wires as follows: a. Securely connect ...

  • Emerson CF730 - page 7

    9. Align the two indents on the inside of the motor housing with the two tabs on the mounting plate (Figure 8). T urn the housing clockwise to hold the housing on the mounting plate. Secure the housing to the mounting plate by installing four pointed M5 x 12mm pan head screws with lockwashers (supplied). 7 SW101 F AN/LIGHT WALL CONTROL (SUPPLIED) B ...

  • Emerson CF730 - page 8

    8 M5 x 6mm WASHER HEAD SCREWS (3) CAPTIVE SCREWS (2) BLADE FLANGE F AN BLADE Figure 9 10. Mount one blade flange to a fan blade using three M5 x 6mm washer head screws (supplied) (Figure 9). Repeat this procedure for the four remaining blades. CAPTIVE SCREWS (2) BLADE FLANGE MOTOR HUB Figure 10 SWITCH HOUSING BLUE WIRE LIGHT FITTER BLACK WIRE SWITC ...

  • Emerson CF730 - page 9

    9 18. Screw in two 60-watt (maximum) candelabra bulbs in the light fitter sockets (Figure 12). Bulbs not supplied. 19. Place the lower glass into the light fitter , aligning the three flat areas on the lower glass flange with the three tabs on the light fitter (Figure 13). Then turn the lower glass clockwise until the glass stops turning. 20. Y our ...

  • Emerson CF730 - page 10

    4. Install a wall control in the wall box containing the “hot” wire first. Connect the black wire of the wall control to the “hot” wire. Securely connect wires with wire connectors supplied. 5. Connect one black wire of the wall control to both remaining traveler wires in the wall box and secure with wire connector supplied. 4. Connect one ...

  • Emerson CF730 - page 11

    NOTE: Retrofit 3-way installations are likely to include two traveler wires between the two wall boxes. In new construction, only one traveler wire Is required. 3-WA Y WIRlNG DIAGRAM: NEW CONSTRUCTION 6. Place wall control into wall box. Screw in place and install decorator style faceplate (included). 7. Next, install the other wall control into th ...

  • Emerson CF730 - page 12

    12 Operating Y our Ceiling Fan IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Y our Fan/Light Wall Control (Figure 19) has full control of your fan and light. However , airflow direction is controlled by a pull chain on the light fitter switch. 1. Restore electrical ...

  • Emerson CF730 - page 13

    13 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING Maintenance IMPORT ANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed. When cleaning, use only a soft brush or lint free cl ...

  • Emerson CF730 - page 14

    Repair Parts 8 17 18 9 10 13 12 2 11 4 3 16 14 15 7 5 HI MED LOW FAN OFF LIGHT ON OFF EMERSON 1 6 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REP AIR P ARTS, AL W A YS GIVE THE FOLLOWING INFORMA TION: • P ART NUMBER • NAME OF ITEM • P ART DESCRIPTION • MODEL NUMBER ...

  • Emerson CF730 - page 15

    15 Part Numbers Key Model No. Model No. Model No. N o . Description CF730WB00 CF730BZH00 CF730AGW00 1 Plate, Mounting 763139 763139 763139 2 Housing, Fan 763126-WB 763126-BZH 763126-AGW 3 Flange Set (full set of one fan) 763127-WB 763127-BZH 763127-AGW 4 Blade Set (full set of one fan) 763132 763132-1 763132-1 5 Harness Assembly , Wiring 763134 763 ...

  • Emerson CF730 - page 16

    Part No. F40BP73150000 Printed in China 03/06 Form No. BP7315 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch circuit fuses start. blown. or circuit breakers. W ARNING: Make su ...

Производитель Emerson Категория Fan

Документы, которые мы получаем от производителя устройства Emerson CF730 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Emerson
- инструкции обслуживания CF730
- паспорта изделия Emerson
- информационные брошюры
- энергетические этикетки Emerson CF730
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Emerson CF730.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Emerson CF730, инструкции обслуживания, короткие инструкции или инструкции пользователя Emerson CF730. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Emerson CF730.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Emerson CF730, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Emerson CF730 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Emerson CF730.

Полная инструкция обслуживания Emerson, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Emerson CF730 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Emerson CF730, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Emerson CF730, которое найдем в данном документе
3. Советы по использованию основных функций устройства Emerson CF730 - которые должны облегчить нам первые шаги во время использования Emerson CF730
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Emerson CF730
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Emerson CF730 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Emerson CF730?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Emerson CF730, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Emerson CF730 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки