Summary
  • York D*V - page 1

    D*V Model Air Cooled Self Contained Indoor Packaged Units 2-25 Tons Preliminary Application Data July 28, 2008 Page 1 ...

  • York D*V - page 2

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 95,000* Design CFM: 3,200 Energy Efficiency Ratio : 11.55 EER** Net Cooling Capacity [Btuh] : 92,000** Net Cooling CFM: 3,200 Refrigerant : R22 Charge : 8.75 Lbs./ circuit Compre ss or No./Type: 2/Scrol l Refrigerant Circuits : 2 / Independent Evaporator Coil Face Area: 8.67 [sq ft] ...

  • York D*V - page 3

    DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only). All units may be field split and installed as separate mo ...

  • York D*V - page 4

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 90. 0 72. 0 97. 5 57. 3 106. 7 43. 8 86. 8 70. 6 94. 1 55. 9 102. 5 42. 2 300 0 80° F 91. 3 86. 7 98. 2 71. 6 107. 6 57. 8 88. 4 85. 8 94. 7 70. 2 103. 4 56. 2 85° F 96 ...

  • York D*V - page 5

    March 2008 DIMENSIONAL DATA DPV096 & DPV120 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA4 (308) 4 of 4 DPV096 AND DPV120 DIMENSIONAL DA T A Page 5 ...

  • York D*V - page 6

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 122,000* Design CFM: 4,000 Energy Efficiency Ratio : 10.60 EER** Net Cooling Capacity [Btuh] : 117,000** Net Cooling CFM: 3,600 Refrigerant : R22 Charge : 9.5 Lbs./ circuit Compre ss or No./Type: 2/Scrol l Refrigerant Circuits : 2 / Independent Evaporator Coil Face Area: 8.67 [sq ft ...

  • York D*V - page 7

    DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only). All units may be field split and installed as separate mo ...

  • York D*V - page 8

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 10 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 115. 4 91. 5 124. 8 73. 0 134. 5 53. 8 111. 0 89. 6 120. 2 71. 1 129. 8 52. 2 360 0 80° F 116. 6 109. 7 125. 8 90. 9 136. 1 72. 4 112. 6 107. 8 120. 9 89. 0 131. ...

  • York D*V - page 9

    March 2008 DIMENSIONAL DATA DPV096 & DPV120 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA5 (308) 4 of 4 DPV096 AND DPV120 DIMENSIONAL DA T A Page 9 ...

  • York D*V - page 10

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 150,000* Design CFM: 4,800 Energy Efficiency Ratio : 10.65 EER** Net Cooling Capacity [Btuh] : 144,000** Net Cooling CFM: 4,800 Refrigerant : R22 Charge : 12.13 Lbs./ circuit Compre ss or No./Type: 2/Scrol l Refrigerant Circuits : 2 / Independent Evaporator Coil Face Area: 13.03 [sq ...

  • York D*V - page 11

    DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only). All units may be field split and installed as separate mo ...

  • York D*V - page 12

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 12 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 140. 0 108. 7 151. 6 87. 4 167. 1 66. 6 135. 4 106. 7 146. 6 85. 3 160. 8 64. 5 430 0 80° F 145. 8 132. 3 152. 8 108. 0 168. 5 88. 6 139. 8 129. 4 147. 1 106. 0 1 ...

  • York D*V - page 13

    DPV144 DPV180 March 2008 DIMENSIONAL DATA DPV144 & DPV180 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA6 (308) 4 of 4 DPV0144 AND DPV180 DIMENSIONAL DA T A Page 13 ...

  • York D*V - page 14

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 186,000* Design CFM: 6,000 Energy Efficiency Ratio : 9.80 EER** Net Cooling Capacity [Btuh] : 178,000** Net Cooling CFM: 5,500 Refrigerant : R22 Charge : 13.83 Lbs./ circuit Compre ss or No./Type: 2/Scrol l Refrigerant Circuits : 2 / Independent Evaporator Coil Face Area: 13.03 [sq ...

  • York D*V - page 15

    DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only). All units may be field split and installed as separate mo ...

  • York D*V - page 16

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 15 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 175. 4 138. 5 189. 7 110. 0 207. 4 82. 9 168. 8 135. 5 182. 8 107. 8 200. 6 81. 8 540 0 80° F 177. 1 165. 8 191. 0 137. 5 209. 1 111. 5 171. 2 163. 1 184. 0 134. ...

  • York D*V - page 17

    DPV144 DPV180 March 2008 DIMENSIONAL DATA DPV144 & DPV180 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA7 (308) 4 of 4 DPV144 AND DPV180 DIMENSIONAL DA T A Page 17 ...

  • York D*V - page 18

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 244,000* Design CFM: 8,000 Energy Efficiency Ratio : 10.10 EER** Net Cooling Capacity [Btuh] : 236,000** Net Cooling CFM: 6,800 Refrigerant : R22 Charge : 18.35 Lbs./ circuit Compre ss or No./Type: 2/Scrol l Refrigerant Circuits : 2 / Independent Evaporator Coil Face Area: 19.00 [sq ...

  • York D*V - page 19

    DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only). All units may be field split and installed as separate mo ...

  • York D*V - page 20

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 20 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 230. 3 184. 1 248. 7 146. 4 269. 3 108. 2 221. 9 180. 3 239. 8 142. 7 258. 3 104. 3 720 0 80° F 233. 3 221. 4 250. 2 182. 6 270. 6 146. 3 223. 9 216. 6 241. 0 178 ...

  • York D*V - page 21

    March 2008 DIMENSIONAL DATA DPV240 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA8 (308) 4 of 4 DPV240 DIMENSIONAL DA T A Page 21 ...

  • York D*V - page 22

    DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 304,000* Design CFM: 10,000 Energy Efficiency Ratio : 9.60 EER** Net Cooling Capacity [Btuh] : 286,000** Net Cooling CFM: 8,800 Refrigerant : R22 Charge : 14.65 Lbs./ circuit Compre ss or No./Type: 3/Scrol l Refrigerant Circuits : 3 / Independent Evaporator Coil Face Area: 19.797 [s ...

  • York D*V - page 23

    DATE: DESCRIPTION: "DPV" SERIES VER Johnson Controls maintains a continuous product improvement policy, t he refore specifications are subject to change without noti ce. March 2008 MECHANICAL SPECIFICATIONS DPV300 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA9 (308) 2 of 4 TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS G ...

  • York D*V - page 24

    DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 25 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 285. 6 225. 4 308. 9 180. 1 339. 4 136. 0 275. 0 220. 8 297. 5 175. 4 325. 1 133. 6 900 0 80° F 291. 7 271. 6 311. 4 224. 0 342. 3 182. 2 281. 0 267. 2 299. 6 219 ...

  • York D*V - page 25

    March 2008 DIMENSIONAL DATA DPV300 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA9 (308) 4 of 4 DPV300 DIMENSIONAL DA T A Page 25 ...

Produzent York Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts York D*V erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen D*V
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York D*V
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York D*V.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York D*V, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York D*V. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York D*V ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York D*V, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York D*V hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York D*V verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York D*V bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York D*V befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York D*V, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York D*V - die uns die ersten Schritte während der Nutzung von York D*V erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York D*V hilft