Bedienungsanleitung Liebert PS400-60S

13 Seiten 0.21 mb
Download

Zur Seite of 13

Summary
  • Liebert PS400-60S - page 1

    PowerSure™ POWER PROTECTION Uninterruptible Power System 250 VA – 600 VA 115 V USER’S MANUAL English R PS250-60S 250 VA PS400-60S 400 VA PS600-60S 600 VA ...

  • Liebert PS400-60S - page 2

    2 IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself except to replace the battery. Opening or removing the cover may expose you to dangerous voltages, even when the AC cord is disconnected from the electrical outlet. Refer all servicing to qualified service personnel. 1. SAVE THESE INSTRUCTIONS. ADHERE TO ALL OP ...

  • Liebert PS400-60S - page 3

    3 unqualified to replace the battery, do not open battery door. Refer to qualified service personnel. INTRODUCTION & SYSTEM DESCRIPTION Congratulations on choosing the Liebert PowerSure™. It provides continuous, conditioned power to microcomputers and other data processing equipment. Upon generation, AC power is clean and stable. However, dur ...

  • Liebert PS400-60S - page 4

    4 1. ON/OFF Button 2. Battery Light (400/600 Only) 3. Check Light (400/600 Only) 4. AC Light 5. Battery Test Button / Alarm Silence (400/600 Only) 6. Option Switc hes 7. Output Receptacles 8. Power Cord Input 9. Circuit Breaker 10. Communications Port (400/600 Only) ATTENTION: Please refer to these drawings when reading this manual. This manual ref ...

  • Liebert PS400-60S - page 5

    5 OPERATING INSTRUCTIONS 1. Check that all power connections to and from the unit are secure and fitted with the correct cables. 2. Press the UPS ON/OFF Button (1) to ON. 3. Switch yo ur equipment ON at their respective power switch(es). 4. Check the condition of the UPS front panel LED's. The 250VA AC LED (4) should be lit. For the 400/600 VA ...

  • Liebert PS400-60S - page 6

    6 INTERFACE FUNCTION DB25 ADAPTER UPS Shutdown/Active High* 19 On Battery/Return 17 On Battery/Normally Open 16 Low Battery/Normally Open 11 Low Battery/Return 9 UPS Shutdown/Return 7 * Remote Shutdown (5 - 12V DC, 5 - 10 mA. max.); battery operation COMPUTER/LAN INTERFACE (400/600 VA ONLY) Optional SiteNet® 1 kits provide connection to a wide ran ...

  • Liebert PS400-60S - page 7

    7 OPTION SWIT CH SETTINGS On the back of your UPS is a bank of option switches (6) with a removable plastic cover. These switches determine transfer levels and operating frequency. Slide the switches to the left to turn them OFF, to the right to turn ON. Turn OFF eq uipment and UPS and unplug the UPS prior to changing switch settings, or the UPS wi ...

  • Liebert PS400-60S - page 8

    8 BATTERY CARE AND USE STORAGE: If the unit is not in continued use, plug in the UPS every 4 to 6 months for 12 hours to recharge the battery. Warranty is void if the battery discharges below the minimum battery cutoff point. To prevent such discharge, DO NOT leave UPS ON for more than two days without plugging it in. BATTERY LIFE & REPLACEMENT ...

  • Liebert PS400-60S - page 9

    9 RESETTING THE CIRCUIT BREAKER If the UPS is overloaded, the circuit breaker (9) at the lower rear of the UPS activates to protect the UPS. If the circuit breaker activates, its center bar will extend. To reset the circuit breaker, simply push the bar back in. If the circuit breaker activates often, ask your dealer to check the UPS sizing or call ...

  • Liebert PS400-60S - page 10

    10 250 VA LED & ALARM INDICATIONS Condition Green AC Light (4) Audible Alarm Status NORMAL/START UP On after Beep Single Beep, then Off Operate Start - Up Test Fail On after Beep Fast Beep for 15 Sec and then Off Operate* Input Frequency Mismatch with Option Switch Setting Input Voltage Below Threshold Off Continuous Will Not Start Overload/Sho ...

  • Liebert PS400-60S - page 11

    11 SPECIFICATIONS FCC ID # N/A BHKAF400T - 60 BKAF600T - 60 Model # / Stock # PS250 - 60/PS250 - 60S PS400 - 60 / PS400 - 60S PS600 - 60 / PS600 - 60S Model Rating 250 VA / 150 W 400 VA / 240 W 600 VA / 360 W Dimensions Unit (W x D x H) 3.51 x 10.18 x 6 .79 in (90 x 262 x 175 mm) 4.25 x 10.18 x 7.02 in (109 x 262 x 186 mm) 4.84 x 10.18 x 8.15 in (1 ...

  • Liebert PS400-60S - page 12

    12 LIMITED WARRANTY Liebert Corporation extends the following LIMITED WARRANTY to the purchaser and to its customer (collectively referred to as t he "Purchaser"): the enclosed Uninterruptible Power System (UPS) and components are free from defects in materials and workmanship under normal use, service, and maintenance FOR A PERIOD OF TWO ...

  • Liebert PS400-60S - page 13

    13 1050 Dearborn Drive Columbus, OH 43229 614 - 888 - 0246 Technical Support U.S.A................................ ................................ 1 - 800 - 222 - 5877 Outside the U.S.A ........................................... 614 - 841 - 6755 U.K................................................................ +44 (0) 1793 553355 France ....... ...

Produzent Liebert Kategorie Power Supply

Dokumente, die wir vom Produzenten des Geräts Liebert PS400-60S erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Liebert
- Bedienungsanleitungen PS400-60S
- Produktkarten Liebert
- Informationsbroschüren
- oder Energieetiketten Liebert PS400-60S
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Liebert PS400-60S.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Liebert PS400-60S, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Liebert PS400-60S. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Liebert PS400-60S ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Liebert PS400-60S, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Liebert PS400-60S hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Liebert PS400-60S verständlich ist.

Eine gänzliche Bedienungsanleitung von Liebert sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Liebert PS400-60S bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Liebert PS400-60S befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Liebert PS400-60S, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Liebert PS400-60S - die uns die ersten Schritte während der Nutzung von Liebert PS400-60S erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Liebert PS400-60S hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Liebert PS400-60S im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Liebert PS400-60S?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Liebert PS400-60S nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Liebert PS400-60S hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)