  • Liebert PS400-60S - page 1

    PowerSure™ POWER PROTECTION Uninterruptible Power System 250 VA – 600 VA 115 V USER’S MANUAL English R PS250-60S 250 VA PS400-60S 400 VA PS600-60S 600 VA ...

  • Liebert PS400-60S - page 2

    2 IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself except to replace the battery. Opening or removing the cover may expose you to dangerous voltages, even when the AC cord is disconnected from the electrical outlet. Refer all servicing to qualified service personnel. 1. SAVE THESE INSTRUCTIONS. ADHERE TO ALL OP ...

  • Liebert PS400-60S - page 3

    3 unqualified to replace the battery, do not open battery door. Refer to qualified service personnel. INTRODUCTION & SYSTEM DESCRIPTION Congratulations on choosing the Liebert PowerSure™. It provides continuous, conditioned power to microcomputers and other data processing equipment. Upon generation, AC power is clean and stable. However, dur ...

  • Liebert PS400-60S - page 4

    4 1. ON/OFF Button 2. Battery Light (400/600 Only) 3. Check Light (400/600 Only) 4. AC Light 5. Battery Test Button / Alarm Silence (400/600 Only) 6. Option Switc hes 7. Output Receptacles 8. Power Cord Input 9. Circuit Breaker 10. Communications Port (400/600 Only) ATTENTION: Please refer to these drawings when reading this manual. This manual ref ...

  • Liebert PS400-60S - page 5

    5 OPERATING INSTRUCTIONS 1. Check that all power connections to and from the unit are secure and fitted with the correct cables. 2. Press the UPS ON/OFF Button (1) to ON. 3. Switch yo ur equipment ON at their respective power switch(es). 4. Check the condition of the UPS front panel LED's. The 250VA AC LED (4) should be lit. For the 400/600 VA ...

  • Liebert PS400-60S - page 6

    6 INTERFACE FUNCTION DB25 ADAPTER UPS Shutdown/Active High* 19 On Battery/Return 17 On Battery/Normally Open 16 Low Battery/Normally Open 11 Low Battery/Return 9 UPS Shutdown/Return 7 * Remote Shutdown (5 - 12V DC, 5 - 10 mA. max.); battery operation COMPUTER/LAN INTERFACE (400/600 VA ONLY) Optional SiteNet® 1 kits provide connection to a wide ran ...

  • Liebert PS400-60S - page 7

    7 OPTION SWIT CH SETTINGS On the back of your UPS is a bank of option switches (6) with a removable plastic cover. These switches determine transfer levels and operating frequency. Slide the switches to the left to turn them OFF, to the right to turn ON. Turn OFF eq uipment and UPS and unplug the UPS prior to changing switch settings, or the UPS wi ...

  • Liebert PS400-60S - page 8

    8 BATTERY CARE AND USE STORAGE: If the unit is not in continued use, plug in the UPS every 4 to 6 months for 12 hours to recharge the battery. Warranty is void if the battery discharges below the minimum battery cutoff point. To prevent such discharge, DO NOT leave UPS ON for more than two days without plugging it in. BATTERY LIFE & REPLACEMENT ...

  • Liebert PS400-60S - page 9

    9 RESETTING THE CIRCUIT BREAKER If the UPS is overloaded, the circuit breaker (9) at the lower rear of the UPS activates to protect the UPS. If the circuit breaker activates, its center bar will extend. To reset the circuit breaker, simply push the bar back in. If the circuit breaker activates often, ask your dealer to check the UPS sizing or call ...

  • Liebert PS400-60S - page 10

    10 250 VA LED & ALARM INDICATIONS Condition Green AC Light (4) Audible Alarm Status NORMAL/START UP On after Beep Single Beep, then Off Operate Start - Up Test Fail On after Beep Fast Beep for 15 Sec and then Off Operate* Input Frequency Mismatch with Option Switch Setting Input Voltage Below Threshold Off Continuous Will Not Start Overload/Sho ...

  • Liebert PS400-60S - page 11

    11 SPECIFICATIONS FCC ID # N/A BHKAF400T - 60 BKAF600T - 60 Model # / Stock # PS250 - 60/PS250 - 60S PS400 - 60 / PS400 - 60S PS600 - 60 / PS600 - 60S Model Rating 250 VA / 150 W 400 VA / 240 W 600 VA / 360 W Dimensions Unit (W x D x H) 3.51 x 10.18 x 6 .79 in (90 x 262 x 175 mm) 4.25 x 10.18 x 7.02 in (109 x 262 x 186 mm) 4.84 x 10.18 x 8.15 in (1 ...

  • Liebert PS400-60S - page 12

    12 LIMITED WARRANTY Liebert Corporation extends the following LIMITED WARRANTY to the purchaser and to its customer (collectively referred to as t he "Purchaser"): the enclosed Uninterruptible Power System (UPS) and components are free from defects in materials and workmanship under normal use, service, and maintenance FOR A PERIOD OF TWO ...

  • Liebert PS400-60S - page 13

    13 1050 Dearborn Drive Columbus, OH 43229 614 - 888 - 0246 Technical Support U.S.A................................ ................................ 1 - 800 - 222 - 5877 Outside the U.S.A ........................................... 614 - 841 - 6755 U.K................................................................ +44 (0) 1793 553355 France ....... ...

Fabbricante Liebert Categoria Power Supply

I documenti che otteniamo dal fabbricante del dispositivoLiebert PS400-60S possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Liebert
- manuali per l’uso PS400-60S
- schede prodotto Liebert
- opuscoli
- o etichette energetiche Liebert PS400-60S
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Liebert PS400-60S.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Liebert PS400-60S, manuali di manutenzione, brevi manuali o manuali utente Liebert PS400-60S. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Liebert PS400-60S.

Manuale completo del dispositivo Liebert PS400-60S, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Liebert PS400-60S dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Liebert PS400-60S.

Il manuale per l’uso completo Liebert, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Liebert PS400-60S - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Liebert PS400-60S, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Liebert PS400-60S che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Liebert PS400-60S - che ci dovrebbe aiutare nei primi passi durante l'uso Liebert PS400-60S
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Liebert PS400-60S
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Liebert PS400-60S in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Liebert PS400-60S?

Utilizza il modulo sottostante

Se non hai risolto il problema con Liebert PS400-60S con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Liebert PS400-60S è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)