Bedienungsanleitung Graham Field 760000-INS-LAB-RevA08

16 Seiten 0.99 mb
Download

Zur Seite of 16

Summary
  • Graham Field 760000-INS-LAB-RevA08 - page 1

    760000 AL TERNA TING PRESSURE / L OW AIR L OSS MA TTRESS SYSTEM USER MANUAL Impor tant: Do not operate the Mattress System without rst reading and understanding this manual! Save this manual for future use. 760000-INS-LAB-RevA08 ...

  • Graham Field 760000-INS-LAB-RevA08 - page 2

    2 760000-INS-LAB-RevA08 Contents INTRODUCTION ..................................................................................... 3 INTENDED USE OF THIS DEVICE ........................................................ 3 IMPORT ANT SAFETY PRECAUTIONS .................................................. 3 DANGER ....................................... ...

  • Graham Field 760000-INS-LAB-RevA08 - page 3

    760000-INS-LAB-RevA08 3 Intr oduCtIon Use this manual for set-up and operation of the Alternating Pr essure / Low Air Loss Mattr ess System. Read all instruc- tions befor e using the mattress system. Save this manual for futur e refer ence. Intended use of thIs devICe The intended use of the Alternating Pr essure / Low Air Loss Mattr ess System is: ...

  • Graham Field 760000-INS-LAB-RevA08 - page 4

    4 760000-INS-LAB-RevA08 d anger T o reduce the risk of electr ocution: DANGER: Always unplug this product immediately after using. DANGER: Do not use this product while bathing. DANGER: Do not place or store this product where it can fall or be pulled into a tub or sink. DANGER: Do not place this product in or drop into water or other liquid. DANGE ...

  • Graham Field 760000-INS-LAB-RevA08 - page 5

    760000-INS-LAB-RevA08 5 W ARNING: Never block the air openings of this product or place it on a soft surface, such as a bed or couch, where the openings may be blocked. Keep the air opening free of lint, hair , and other similar particles. W ARNING: Never drop or insert any object into any opening or hose. W ARNING: Do not use this product in the p ...

  • Graham Field 760000-INS-LAB-RevA08 - page 6

    6 760000-INS-LAB-RevA08 For U.S. and Canada only E228589 53DG Medical Equipment: Air Pump with respect to electrical shock, re and mechanical hazards only in accordance with UL60601-1 and CAN/CSA C22.2 No. 601.1 pr oduCt desCrIptIon pump and ma ttress sy stem pump and mattress system CPR valves mattress-pump connectors mattress foot end symbol p ...

  • Graham Field 760000-INS-LAB-RevA08 - page 7

    760000-INS-LAB-RevA08 7 pump: rear main power switch power cord receptacle fuse hanger filter pump: front p anel cycle time adjust button; cycle time indicators at right of button decrease pr essure button; pressur e level indicators at right of button panel lock button; panel lock indicator at right of button therapy adjust button; therapy mode in ...

  • Graham Field 760000-INS-LAB-RevA08 - page 8

    8 760000-INS-LAB-RevA08 incr ease pressur e under the buttocks). Press the therapy adjust button at the left end of the r ow to cycle between the settings. The selected therapy mode setting's indicator will illuminate. F r ont panel four th row Panel lock button: The panel lock pr otects the panel set- tings fr om accidental change. Press to l ...

  • Graham Field 760000-INS-LAB-RevA08 - page 9

    760000-INS-LAB-RevA08 9 Ser vice indicator: Mechanical failure, service requir ed; contact your Graham-eld equipment pr ovider . Inst alla tIon unp aCkIng 1. Befor e unpacking, check for obvious damage to the car- ton or its contents. If damage is evident, please notify the carrier and your Graham-Field equipment pr ovider . 2. Remove all loose ...

  • Graham Field 760000-INS-LAB-RevA08 - page 10

    10 760000-INS-LAB-RevA08 s Caution: Place the device in a position wher e the car e- giver and/or doctor can access it easily . 5. Connect the mattr ess-pump air hose quick connector; ensur e that the connector has clicked secur ely into place befor e continuing. s Caution: Ensur e that the air hoses ar e not kinked or tucked under the mattr ess. W ...

  • Graham Field 760000-INS-LAB-RevA08 - page 11

    760000-INS-LAB-RevA08 11 Note: The mattress system will automatically enter Autofirm mode for the quickest inflation at set-up; initial inflation takes approximately twenty minutes. 3. The pump will begin delivering air into the mattr ess. 4. When the selected pr essure level is r eached, the pump will enter alternating mode. The mattr ess can t ...

  • Graham Field 760000-INS-LAB-RevA08 - page 12

    12 760000-INS-LAB-RevA08 transport Cap In case of power failur e or trans- port: Disconnect the quick connec- tor and cap the mattr ess with the transport cap to slow deation. Cpr funCtIon If CPR must be performed on the patient while the mattr ess is in use, to immediately deate the mat- tr ess, either: 1. Pull the CPR valves fr om the mattr ...

  • Graham Field 760000-INS-LAB-RevA08 - page 13

    760000-INS-LAB-RevA08 13 general maIntenanCe 1. Check main power cor d for abrasion or excessive wear . 2. Check mattr ess cover for signs of wear or damage. En- sur e mattress cover and tubes ar e connected correctly . 3. Check airow fr om the air hose connector . The airow should alternate between each connector ever y half- cycle time if i ...

  • Graham Field 760000-INS-LAB-RevA08 - page 14

    14 760000-INS-LAB-RevA08 st orage 1. Lay the mattr ess out at and upside down. 2. Roll fr om the head end towar d the foot end. 3. Str etch the foot-end strap around the r olled mattress to pr event unrolling. 4. Stor e mattress and pump in a dust-fr ee environment with no exposur e to direct sunlight. s Caution: Do not fold, cr ease or stack ma ...

  • Graham Field 760000-INS-LAB-RevA08 - page 15

    760000-INS-LAB-RevA08 15 Mattress Specication Model 8" mattress Dimensions (L x W x H) 78.7" x 35.4" x 8" (200 x 90 x 20.3 cm) Weight 16.5 lb (7.5 kg) Warranty GF Health Pr oducts, Inc. warrants the Lumex AltaDyne Plus 760000 Alternating Pr essure / Low Air Loss Mattr ess Sys- tem for a period of twelve months for defects in ...

  • Graham Field 760000-INS-LAB-RevA08 - page 16

    USA, Corporate Headquar ters: Graham-Field Health Products 2935 Nor theast Parkway Atlanta, Georgia 30360 telephone: 800-347-5678, 770-447-1609 fax: 800-726-0601, 678-291-3232 www .grahamfield.com 760000-INS-LAB-RevA08 © 2008 GF Health Products, Inc. ...

Produzent Graham Field Kategorie Camping Equipment

Dokumente, die wir vom Produzenten des Geräts Graham Field 760000-INS-LAB-RevA08 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Graham Field
- Bedienungsanleitungen 760000-INS-LAB-RevA08
- Produktkarten Graham Field
- Informationsbroschüren
- oder Energieetiketten Graham Field 760000-INS-LAB-RevA08
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Graham Field 760000-INS-LAB-RevA08.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Graham Field 760000-INS-LAB-RevA08, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Graham Field 760000-INS-LAB-RevA08. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Graham Field 760000-INS-LAB-RevA08 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Graham Field 760000-INS-LAB-RevA08, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Graham Field 760000-INS-LAB-RevA08 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Graham Field 760000-INS-LAB-RevA08 verständlich ist.

Eine gänzliche Bedienungsanleitung von Graham Field sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Graham Field 760000-INS-LAB-RevA08 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Graham Field 760000-INS-LAB-RevA08 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Graham Field 760000-INS-LAB-RevA08, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Graham Field 760000-INS-LAB-RevA08 - die uns die ersten Schritte während der Nutzung von Graham Field 760000-INS-LAB-RevA08 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Graham Field 760000-INS-LAB-RevA08 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Graham Field 760000-INS-LAB-RevA08 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Graham Field 760000-INS-LAB-RevA08?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Graham Field 760000-INS-LAB-RevA08 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Graham Field 760000-INS-LAB-RevA08 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)