  • GE GEK-45404F - page 1

    GEK-45404F   MULTILIN  GE Power Management INSTRUCTIONS OVERVOLTAGE RELAYS TYPES IAV, 51 D K 52 C D K GE Power Management 205 Great Valley Parkway Malvern, PA 19355, USA Click here to get to our homepage: http://www.gemultilin.com/ ...

  • GE GEK-45404F - page 2

    GEK-45404 2 DESCRIPTION ................................................................................................................................................... 3 APPLICATION ................................................................................................................................................... 4 RATINGS ...... ...

  • GE GEK-45404F - page 3

    GEK-45404 3 D ES CRIPTIO N Thes e are si ngle- phase, sens itiv e overvo lta g e relay s o f th e i nduc ti on disk construc ti on. The y a r e e quipped w it h a tim e dia l s o a s t o provid e adj ustabl e tim e dela y i n thei r opera ti on. Th e relay s are principa ll y a pp li cab le f o r sen s itiv e overvo lta g e gr ound det ec ti on fo ...

  • GE GEK-45404F - page 4

    GEK-45404 4 A PPLICA TION Thes e are single- phase, sens itive , time- dela y overvo ltag e relay s . The y a r e p rincipa ll y a pp li cabl e for sens itiv e overvo ltag e gr ound det ec ti on fo r high- impedan ce gr ounded g enerator s o r for ung rounded powe r s y st ems . Thes e relay s a ll hav e a capac ito r i n serie s w it h th e opera ...

  • GE GEK-45404F - page 5

    GEK-45404 5 br oke n de lt a vo ltag e w ill therefo r e be th ree time s th e norma l delt a phase-to-phas e vo ltag e w it h no fault. RA TINGS Th e opera ting-cir cuit rating s ava ilabl e are s hown in Tabl e I . Th e opera tin g co il will sta nd rated voltage continuously on any tap. RELAY VOLTAGE RATINGS 60HZ 50HZ IAV51D 115 115 199 199 345 ...

  • GE GEK-45404F - page 6

    GEK-45404 6 suc h tha t the tri ppin g cu rren t doe s no t pa ss thr oug h th e c ont act s o f th e targe t a nd s eal-i n co il o f the protective relay. BURDENS Burdens for the various relay types are give in Tables IIIA and B. TABLE IIIA 60 - Cycle Burdens Rated Voltage RELAY TYPES VOLTAGE RATING TAP**SETTING VOLT-AMPS POWER FACTOR WATTS 1AV51 ...

  • GE GEK-45404F - page 7

    GEK-45404 7 50 - Cycle Burdens at Rated Voltages RELAY TYPES VOLTAGE RATING TAP**SETTING VOLT-AMPS POWER FACTOR WATTS IAV51D 345 A(28) 31.9 0.36 11.4 B(42) 28.3 0.56 15.8 C(70) 21.0 0.79 16.6 D(112) 12.8 0.93 11.9 IAV51K 67 A(5.4) 28.8 0.29 8.4 IAV52K B(7.5) 26.6 0.45 12.1 C(12.5) 21.1 0.71 14.9 D(20) 16.0 0.86 13.7 115 No Taps 25.0 0.41 10.1 IAV52 ...

  • GE GEK-45404F - page 8

    GEK-45404 8 50 - Cycle Burden at Rated Voltages RELAY TYPES VOLTAGE RATINGS TAP**SETTINGS VOLT-AMPS POWER FACTOR WATTS 1AV51D 115 A(10) 0.52 0.98 0.52 B(15) 0.67 0.99 0.67 C(25) 1.0 1.0 1.0 D(40) 1.52 1.0 1.52 IAV51D 199 A(16) 0.32 0.85 0.27 B(24) 0.5 0.93 0.46 C(40) 0.83 0.97 0.81 D(64) 1.33 0.99 1.32 IAV51D 345 A(28) 0.39 0.96 0.37 B(42) 0.58 0.9 ...

  • GE GEK-45404F - page 9

    GEK-45404 9 Th e I AV 52 K rela y i s s imila r t o t h e I AV 51 K ex cep t that it ha s tw o, inst ea d o f one, norma lly - open contacts. Th e I AV 52 C i s a low-pi c kup, time- overvo ltag e rela y w it h tw o norma lly- open cont acts . I t ha s a seal- i n element . I t ha s a capac ito r c onn ecte d i n serie s w it h th e opera tin g c o ...

  • GE GEK-45404F - page 10

    GEK-45404 10 RECEIVING , HA NDLI NG , A ND STORA GE RECEIVING Thes e relays , whe n no t shi pped a s a par t o f a c ontro l pane l , w ill b e shi pped in cart on s desig ne d to prot ec t them ag ainst damage . I mmediate l y upon r eceip t o f th e rel ay , an exa minati on shoul d b e made fo r an y d a m a g e sus tain e d durin g s hi pme nt ...

  • GE GEK-45404F - page 11

    GEK-45404 11 CAUTION : Ev er y ci rcui t i n th e dra wou t cas e h a s a n aux iliar y brush . I t i s esp ecia ll y importan t o n cu rrent circuit s a nd oth er circuit s wit h shortin g bar s tha t th e aux iliar y brus h be ben t hig h enough to en gag e th e co nn ectin g p lu g o r t es t pl u g bef o re the mai n brushes d o. Thi s w ill p ...

  • GE GEK-45404F - page 12

    GEK-45404 12 ELECTRICAL TESTS Drawout Relays - General Sin ce a ll draw ou t relay s i n servi ce oper at e i n thei r cas es , it i s r eco mme nded tha t the y b e teste d in thei r cas e s o r a n equivalen t st ee l case . In thi s wa y a n y m a gn e ti c e ff ect s o f th e enclosur e w ill be accuratel y dup li cate d durin g tes ting . A re ...

  • GE GEK-45404F - page 13

    GEK-45404 13 INST A LLA TI ON INSPECTION A t th e tim e o f i nsta llati on, th e rela y s houl d b e ins p ect e d fo r t arni sh e d cont acts , loos e screws , o r o th er impe rf ec ti ons . I f an y t r oubl e i s f ound, it s houl d b e co rr ect ed ; s ee MAIN TE NANCE . Ch ec k the nameplate for model number and rating. LOCATION Th e loca t ...

  • GE GEK-45404F - page 14

    GEK-45404 14 ADJUSTMENTS Target and Seal-in Unit Fo r tri p co il s opera tin g on cu rren t rangin g fro m 0.2 up to 2.0 ampere s a t th e minimum c ontrol voltage, set the target and seal-in tap plug in the 0.2- ampere tap. Fo r tri p co il s opera tin g on cu rrent s rangin g fro m 2 t o 30 ampere s a t th e minimum c ontro l vo ltag e, place th ...

  • GE GEK-45404F - page 15

    GEK-45404 15 Time Setting Th e tim e o f opera ti on o f th e overvo ltag e rela y i s deter mine d pr imaril y b y t h e se ttin g o f th e tim e di al. Furthe r adj us tmen t i s obtaine d b y m ovin g th e p ermanen t magnet a l on g it s s uppor tin g s hel f ; m oving the magnet in toward the back of the relay decreases the time, while moving ...

  • GE GEK-45404F - page 16

    GEK-45404 16 CONTACT CLEANING Fo r cl eani n g fin e s ilve r c ont act s , a flexi ble burnishin g t oo l s houl d b e u se d. Thi s c onsist s o f a flexi bl e stri p o f meta l wit h an etched roug hened su rf ace , resemb lin g i n e ff ec t a s upe rfin e f ile . The po lishin g ac ti on i s s o de li cate tha t no scratche s ar e left , y e t ...

  • GE GEK-45404F - page 17

    GEK-45404 17 LIS T O F FI G UR ES FIG. 1 (8043181) TYPE IAV51D RELAY, REMOVED FROM CASE, FRONT VIEW FIG. 2 (8043182) TYPE IAV51D RELAY, REMOVED FROM CASE, REAR VIEW FI G . 3 (K6400439-5) I N TER NA L C ONNECTION S O F TH E TYPE I AV 51 D REL AY, FRONT VIEW FI G . 4 (0362A514-3) I N TER NA L C ONNECTION S O F TH E TYPE I AV 51 K REL AY, FRONT VIEW F ...

  • GE GEK-45404F - page 18

    GEK-45404 18 FIG. 1 (8043181-0) TYPE IAV51D RELAY, REMOVED FROM CASE, FRONT VIEW ...

  • GE GEK-45404F - page 19

    GEK-45404 19 FIG. 2 (8043182-0) TYPE IAV51D RELAY, REMOVED FROM CASE, R EAR VIEW ...

  • GE GEK-45404F - page 20

    GEK-45404 20 FIG. 3 (K-6400439-5) INTERNAL CONNECTIONS OF THE TYPE IAV51D RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 21

    GEK-45404 21 FIG. 4 (362A514-3) INTERNAL CONNECTIONS OF THE TYPE IAV51K RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 22

    GEK-45404 22 FIG. 5 (K-6556505-0) INTERNAL CONNECTIONS OF THE TYPE IAV52C RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 23

    GEK-45404 23 FIG. 6 (418A790-0) INTERNAL CONNECTIONS OF THE TYPE IAV52D RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 24

    GEK-45404 24 FIG. 7 (0257A8379-0) INTERNAL CONNECTIONS OF THE TYPEIAV52K RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 25

    GEK-45404 25 FIG. 8 (0275A2004-0) EXTERNAL CONNECTION DIAGRAM OF TYPES IAV51KAND IAV52K FOR GENERATOR GROUND-FAULT PROTECTION ...

  • GE GEK-45404F - page 26

    GEK-45404 26 FIG. 9 (0275A2003-0) EXTERNAL CONNECTION DIAGRAM OF TYPE IAV51D, IAV52C AND IAV52D FOR GROUND-FAULT DETECTION ON AN UNGROUNDED SYSTEM ...

  • GE GEK-45404F - page 27

    GEK-45404 27 FIG. 10 (K6154391-3) TEST CONNECTIONS FOR OVERVOLTAGE RELAYS ...

  • GE GEK-45404F - page 28

    GEK-45404 28 NOTE: TD=Time Dial setting FIG. 11 (0178A8140-0) TIME VOLTAGE CURVES FOR TYPES IAV51D, 51K, 52D, AND 52K RELAYS ...

  • GE GEK-45404F - page 29

    GEK-45404 29 FIG. 12 (8025039-0) CROSS SECTION OF DRAWOUT CASE SHOWING POSITION OF AUXILIARY BRUSH ...

  • GE GEK-45404F - page 30

    GEK-45404 30 FIG. 13 (0275A4399-0) OUTLINE OF IAV51K AND IAV52K EXTERNAL CAPACITOR ...

  • GE GEK-45404F - page 31

    GEK-45404 31 FIG. 14 (K6209270-2) OUTLINE AND PANEL DRILLING FOR RELAY TYPES IAV51D, 52D AND IAV52C ...

  • GE GEK-45404F - page 32

    GEK-45404 32 * FIG. 15 (K6209271-8) OUTLINE AND PANEL DRILLLING FOR RELAY TYPES IAV51K AND IAV52K ...

Produzent GE Kategorie Portable Generator

Dokumente, die wir vom Produzenten des Geräts GE GEK-45404F erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen GE
- Bedienungsanleitungen K-45404F
- Produktkarten GE
- Informationsbroschüren
- oder Energieetiketten GE GEK-45404F
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung GE GEK-45404F.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen GE GEK-45404F, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen GE GEK-45404F. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts GE GEK-45404F ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts GE GEK-45404F, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von GE GEK-45404F hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von GE GEK-45404F verständlich ist.

Eine gänzliche Bedienungsanleitung von GE sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von GE GEK-45404F bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von GE GEK-45404F befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich GE GEK-45404F, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts GE GEK-45404F - die uns die ersten Schritte während der Nutzung von GE GEK-45404F erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit GE GEK-45404F hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von GE GEK-45404F im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich GE GEK-45404F?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit GE GEK-45404F nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit GE GEK-45404F hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)