    GEK-45404F   MULTILIN  GE Power Management INSTRUCTIONS OVERVOLTAGE RELAYS TYPES IAV, 51 D K 52 C D K GE Power Management 205 Great Valley Parkway Malvern, PA 19355, USA Click here to get to our homepage: http://www.gemultilin.com/ ...

  • GE GEK-45404F - page 2

    GEK-45404 2 DESCRIPTION ................................................................................................................................................... 3 APPLICATION ................................................................................................................................................... 4 RATINGS ...... ...

  • GE GEK-45404F - page 3

    GEK-45404 3 D ES CRIPTIO N Thes e are si ngle- phase, sens itiv e overvo lta g e relay s o f th e i nduc ti on disk construc ti on. The y a r e e quipped w it h a tim e dia l s o a s t o provid e adj ustabl e tim e dela y i n thei r opera ti on. Th e relay s are principa ll y a pp li cab le f o r sen s itiv e overvo lta g e gr ound det ec ti on fo ...

  • GE GEK-45404F - page 4

    GEK-45404 4 A PPLICA TION Thes e are single- phase, sens itive , time- dela y overvo ltag e relay s . The y a r e p rincipa ll y a pp li cabl e for sens itiv e overvo ltag e gr ound det ec ti on fo r high- impedan ce gr ounded g enerator s o r for ung rounded powe r s y st ems . Thes e relay s a ll hav e a capac ito r i n serie s w it h th e opera ...

  • GE GEK-45404F - page 5

    GEK-45404 5 br oke n de lt a vo ltag e w ill therefo r e be th ree time s th e norma l delt a phase-to-phas e vo ltag e w it h no fault. RA TINGS Th e opera ting-cir cuit rating s ava ilabl e are s hown in Tabl e I . Th e opera tin g co il will sta nd rated voltage continuously on any tap. RELAY VOLTAGE RATINGS 60HZ 50HZ IAV51D 115 115 199 199 345 ...

  • GE GEK-45404F - page 6

    GEK-45404 6 suc h tha t the tri ppin g cu rren t doe s no t pa ss thr oug h th e c ont act s o f th e targe t a nd s eal-i n co il o f the protective relay. BURDENS Burdens for the various relay types are give in Tables IIIA and B. TABLE IIIA 60 - Cycle Burdens Rated Voltage RELAY TYPES VOLTAGE RATING TAP**SETTING VOLT-AMPS POWER FACTOR WATTS 1AV51 ...

  • GE GEK-45404F - page 7

    GEK-45404 7 50 - Cycle Burdens at Rated Voltages RELAY TYPES VOLTAGE RATING TAP**SETTING VOLT-AMPS POWER FACTOR WATTS IAV51D 345 A(28) 31.9 0.36 11.4 B(42) 28.3 0.56 15.8 C(70) 21.0 0.79 16.6 D(112) 12.8 0.93 11.9 IAV51K 67 A(5.4) 28.8 0.29 8.4 IAV52K B(7.5) 26.6 0.45 12.1 C(12.5) 21.1 0.71 14.9 D(20) 16.0 0.86 13.7 115 No Taps 25.0 0.41 10.1 IAV52 ...

  • GE GEK-45404F - page 8

    GEK-45404 8 50 - Cycle Burden at Rated Voltages RELAY TYPES VOLTAGE RATINGS TAP**SETTINGS VOLT-AMPS POWER FACTOR WATTS 1AV51D 115 A(10) 0.52 0.98 0.52 B(15) 0.67 0.99 0.67 C(25) 1.0 1.0 1.0 D(40) 1.52 1.0 1.52 IAV51D 199 A(16) 0.32 0.85 0.27 B(24) 0.5 0.93 0.46 C(40) 0.83 0.97 0.81 D(64) 1.33 0.99 1.32 IAV51D 345 A(28) 0.39 0.96 0.37 B(42) 0.58 0.9 ...

  • GE GEK-45404F - page 9

    GEK-45404 9 Th e I AV 52 K rela y i s s imila r t o t h e I AV 51 K ex cep t that it ha s tw o, inst ea d o f one, norma lly - open contacts. Th e I AV 52 C i s a low-pi c kup, time- overvo ltag e rela y w it h tw o norma lly- open cont acts . I t ha s a seal- i n element . I t ha s a capac ito r c onn ecte d i n serie s w it h th e opera tin g c o ...

  • GE GEK-45404F - page 10

    GEK-45404 10 RECEIVING , HA NDLI NG , A ND STORA GE RECEIVING Thes e relays , whe n no t shi pped a s a par t o f a c ontro l pane l , w ill b e shi pped in cart on s desig ne d to prot ec t them ag ainst damage . I mmediate l y upon r eceip t o f th e rel ay , an exa minati on shoul d b e made fo r an y d a m a g e sus tain e d durin g s hi pme nt ...

  • GE GEK-45404F - page 11

    GEK-45404 11 CAUTION : Ev er y ci rcui t i n th e dra wou t cas e h a s a n aux iliar y brush . I t i s esp ecia ll y importan t o n cu rrent circuit s a nd oth er circuit s wit h shortin g bar s tha t th e aux iliar y brus h be ben t hig h enough to en gag e th e co nn ectin g p lu g o r t es t pl u g bef o re the mai n brushes d o. Thi s w ill p ...

  • GE GEK-45404F - page 12

    GEK-45404 12 ELECTRICAL TESTS Drawout Relays - General Sin ce a ll draw ou t relay s i n servi ce oper at e i n thei r cas es , it i s r eco mme nded tha t the y b e teste d in thei r cas e s o r a n equivalen t st ee l case . In thi s wa y a n y m a gn e ti c e ff ect s o f th e enclosur e w ill be accuratel y dup li cate d durin g tes ting . A re ...

  • GE GEK-45404F - page 13

    GEK-45404 13 INST A LLA TI ON INSPECTION A t th e tim e o f i nsta llati on, th e rela y s houl d b e ins p ect e d fo r t arni sh e d cont acts , loos e screws , o r o th er impe rf ec ti ons . I f an y t r oubl e i s f ound, it s houl d b e co rr ect ed ; s ee MAIN TE NANCE . Ch ec k the nameplate for model number and rating. LOCATION Th e loca t ...

  • GE GEK-45404F - page 14

    GEK-45404 14 ADJUSTMENTS Target and Seal-in Unit Fo r tri p co il s opera tin g on cu rren t rangin g fro m 0.2 up to 2.0 ampere s a t th e minimum c ontrol voltage, set the target and seal-in tap plug in the 0.2- ampere tap. Fo r tri p co il s opera tin g on cu rrent s rangin g fro m 2 t o 30 ampere s a t th e minimum c ontro l vo ltag e, place th ...

  • GE GEK-45404F - page 15

    GEK-45404 15 Time Setting Th e tim e o f opera ti on o f th e overvo ltag e rela y i s deter mine d pr imaril y b y t h e se ttin g o f th e tim e di al. Furthe r adj us tmen t i s obtaine d b y m ovin g th e p ermanen t magnet a l on g it s s uppor tin g s hel f ; m oving the magnet in toward the back of the relay decreases the time, while moving ...

  • GE GEK-45404F - page 16

    GEK-45404 16 CONTACT CLEANING Fo r cl eani n g fin e s ilve r c ont act s , a flexi ble burnishin g t oo l s houl d b e u se d. Thi s c onsist s o f a flexi bl e stri p o f meta l wit h an etched roug hened su rf ace , resemb lin g i n e ff ec t a s upe rfin e f ile . The po lishin g ac ti on i s s o de li cate tha t no scratche s ar e left , y e t ...

  • GE GEK-45404F - page 17

    GEK-45404 17 LIS T O F FI G UR ES FIG. 1 (8043181) TYPE IAV51D RELAY, REMOVED FROM CASE, FRONT VIEW FIG. 2 (8043182) TYPE IAV51D RELAY, REMOVED FROM CASE, REAR VIEW FI G . 3 (K6400439-5) I N TER NA L C ONNECTION S O F TH E TYPE I AV 51 D REL AY, FRONT VIEW FI G . 4 (0362A514-3) I N TER NA L C ONNECTION S O F TH E TYPE I AV 51 K REL AY, FRONT VIEW F ...

  • GE GEK-45404F - page 18

    GEK-45404 18 FIG. 1 (8043181-0) TYPE IAV51D RELAY, REMOVED FROM CASE, FRONT VIEW ...

  • GE GEK-45404F - page 19

    GEK-45404 19 FIG. 2 (8043182-0) TYPE IAV51D RELAY, REMOVED FROM CASE, R EAR VIEW ...

  • GE GEK-45404F - page 20

    GEK-45404 20 FIG. 3 (K-6400439-5) INTERNAL CONNECTIONS OF THE TYPE IAV51D RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 21

    GEK-45404 21 FIG. 4 (362A514-3) INTERNAL CONNECTIONS OF THE TYPE IAV51K RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 22

    GEK-45404 22 FIG. 5 (K-6556505-0) INTERNAL CONNECTIONS OF THE TYPE IAV52C RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 23

    GEK-45404 23 FIG. 6 (418A790-0) INTERNAL CONNECTIONS OF THE TYPE IAV52D RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 24

    GEK-45404 24 FIG. 7 (0257A8379-0) INTERNAL CONNECTIONS OF THE TYPEIAV52K RELAY, FRONT VIEW ...

  • GE GEK-45404F - page 25

    GEK-45404 25 FIG. 8 (0275A2004-0) EXTERNAL CONNECTION DIAGRAM OF TYPES IAV51KAND IAV52K FOR GENERATOR GROUND-FAULT PROTECTION ...

  • GE GEK-45404F - page 26

    GEK-45404 26 FIG. 9 (0275A2003-0) EXTERNAL CONNECTION DIAGRAM OF TYPE IAV51D, IAV52C AND IAV52D FOR GROUND-FAULT DETECTION ON AN UNGROUNDED SYSTEM ...

  • GE GEK-45404F - page 27

    GEK-45404 27 FIG. 10 (K6154391-3) TEST CONNECTIONS FOR OVERVOLTAGE RELAYS ...

  • GE GEK-45404F - page 28

    GEK-45404 28 NOTE: TD=Time Dial setting FIG. 11 (0178A8140-0) TIME VOLTAGE CURVES FOR TYPES IAV51D, 51K, 52D, AND 52K RELAYS ...

  • GE GEK-45404F - page 29

    GEK-45404 29 FIG. 12 (8025039-0) CROSS SECTION OF DRAWOUT CASE SHOWING POSITION OF AUXILIARY BRUSH ...

  • GE GEK-45404F - page 30

    GEK-45404 30 FIG. 13 (0275A4399-0) OUTLINE OF IAV51K AND IAV52K EXTERNAL CAPACITOR ...

  • GE GEK-45404F - page 31

    GEK-45404 31 FIG. 14 (K6209270-2) OUTLINE AND PANEL DRILLING FOR RELAY TYPES IAV51D, 52D AND IAV52C ...

  • GE GEK-45404F - page 32

    GEK-45404 32 * FIG. 15 (K6209271-8) OUTLINE AND PANEL DRILLLING FOR RELAY TYPES IAV51K AND IAV52K ...

Fabricante GE Categoría Portable Generator

Los documentos del dispositivo GE GEK-45404F que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos GE
- manuales de instrucciones K-45404F
- hojas de producto GE
- folletos informativos
- o etiquetas energéticas GE GEK-45404F
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones GE GEK-45404F.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje GE GEK-45404F, instrucciones de servicio, instrucciones cortas o instrucciones de usuario GE GEK-45404F. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto GE GEK-45404F.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo GE GEK-45404F, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar GE GEK-45404F. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de GE GEK-45404F.

El manual de instrucciones completo de GE debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual GE GEK-45404F - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice GE GEK-45404F, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de GE GEK-45404F que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo GE GEK-45404F - que deben facilitarnos los primeros pasos durante el uso de GE GEK-45404F
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con GE GEK-45404F
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de GE GEK-45404F en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de GE GEK-45404F?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con GE GEK-45404F, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con GE GEK-45404F probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)