    ACCULINK 3161 DSU/CSU QUICK REFERENCE Document No. 3161-A2-GL1 1-40 ...

  • Paradyne 3161 DSU - page 2

    Copyright  1998 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law . No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, m ...

  • Paradyne 3161 DSU - page 3

    TM 1 ACCULINK 3161 DSU/CSU Quick Reference Document Number 3161-A2-GL1 1-40 February 1998 Quick Start Procedur e The following procedure is for experienced DSU/CSU users who are familiar with the 3161 DSU/CSU installation process and have no special requirements for their application. See the ACCULINK 316x Data Service Unit/Channel Service Unit Ope ...

  • Paradyne 3161 DSU - page 4

    2 3. Attach the network cable to the Auxiliary Backplane using either a 50-pin cable or the T1 Network Interface Adapter . Connect the other end of the network cable to the connection provided by the telephone company . 496-14386-0 3 Auxiliary Backplane over Slots 9–16 COMSPHERE 3000 Series Carrier (Rear) T1 Network Cable Cable Retainer 4. T urn ...

  • Paradyne 3161 DSU - page 5

    3 5. Insert the DSU/CSU circuit card into the appropriate slot in the carrier . The power-up self-test begins. 495-1479 7 6. If you intend to use front panel emulation, connect the cable from the PC to Port 2 on the Auxiliary Backplane using the COM port adapter and COM-port-to-PC cable. 7. If you do not intend to use the DTE Drop/Insert T1 port, d ...

  • Paradyne 3161 DSU - page 6

    4 Configuration Options Configuration options are accessed from the Cnfig branch of the front panel menu. DSU ESF Stat 97-15577 Dev HS S T est Pe r f TS t a t LE D ID T1 Prtn Pr tn User T elco Cur 24T ot Intvl Far Near Cur 8T ot Intvl T est R lpbk Lpbk Pt rn s La mp QRSS 51 1 Abort Mon LLBUP LLBDN 54UP 54DN FT1UP FT1DN PLB DLB RLB LLB Abort DCLB DT ...

  • Paradyne 3161 DSU - page 7

    5 T able 1. DTE Interface Configuration Options Option Factory 1 Factory 2 Comments/Description DTE Port: Enab Enab Enables the use of the DTE DTE Port: Disab Disab Enables the use of the DTE Drop/Insert port. DTE Framing: D4 D4 Selects D4 or ESF framing format DTE Framing: ESF ESF Selects D4 or ESF framing format. DTE Coding: AMI AMI Selects AMI o ...

  • Paradyne 3161 DSU - page 8

    6 T able 2. Port Configuration Options (2 of 3) Option Comments/Description Factory 2 Factory 1 Disab Disab Port LB: DTLB DTLB Port-initiated Loopbacks, allows Loopbacks to be initiated through Port LB: DCLB DCLB p, Loopbacks to be initiated through the port by the external DTE. Both Both ep o b y ee e a Disab Disab All Ones: DTR DTR All ones sent ...

  • Paradyne 3161 DSU - page 9

    7 T able 2. Port Configuration Options (3 of 3) Option Comments/Description Factory 2 Factory 1 Far end: Disab Disab Specifies whether the device will maintain far end performance Far-end: Maint Maint p maintain far-end performance statistics. Mgmt Link: Enab Enab S p ecifies whether the EDL Mgmt Link: Disab Disab S pec ifi es w h e th er th e EDL ...

  • Paradyne 3161 DSU - page 10

    8 T able 4. DTE Drop/Insert Port Channel Configuration Options Line 1 Displays: Line 2 Displays: Meaning Comments/Description — Unassigned N1 N2 N3 ...... N24: D1, D2 ... D24 Channel assigned to this DTE channel Function key under the channel (N1, N2, etc.) selects the DTE channel to assi g n ( D1 , D2 , ... D24 , N1 N2 N3 ...... N24 : Prt1 Prt2 ...

  • Paradyne 3161 DSU - page 11

    9 T able 5. Data Port Channel Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description NET NET Assigns this port to channels on Assign T o: DTE DTE Assigns this port to channels on the Network or DSX-1 T1 interface, tt h t Assign T o: Prt n Prt n the Network or DSX 1 T1 interface, or to another port. Block Block Determines how ...

  • Paradyne 3161 DSU - page 12

    10 T able 5. Data Port Channel Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description Clear Clear Clears (unassigns) channels for this port. Start At: N1 (D1) N2 (D2) N3 (D3) N4 (D4) N5 (D5) N6 (D6) N7 (D7) N8 (D8) N9 (D9) N10 (D10) N1 1 (D1 1) N12 (D12) N13 (D13) N14 (D14) N15 (D15) N16 (D16) N17 (D17) N18 (D18) N19 (D19) N ...

  • Paradyne 3161 DSU - page 13

    11 T able 6. General Configuration Options Option Factory 1 Factory 2 Comments/Description Gen Y ellow: Enab Enab Y ellow alarm is g enerated b y the G en Y e ll ow: (Generate Y ellow) Disab Disab Y e ll ow a l arm i s genera t e d b y th e DSU/CSU on LOS, LOF , or AIS. NET NET DTE DTE Selects the clock source to be Clock Src: Prt1 Prt1 Selects the ...

  • Paradyne 3161 DSU - page 14

    12 T able 7. User Configuration Options (1 of 3) Option Factory 1 Factory 2 Comments/Description Self - T est: Enab Enab Allows bypass of self-test on Self-T est: Disab Disab Allows bypass of self - test on initialization. Dial - In: Enab Enab Controls whether dial-in access is Dial-In: Disab Disab Controls whether dial - in access is allowed. Pass ...

  • Paradyne 3161 DSU - page 15

    13 T able 7. User Configuration Options (2 of 3) Option Comments/Description Factory 2 Factory 1 1.2 1.2 2.4 2.4 Com Rate: 4.8 4.8 Com Rate: (Communication Port Rt) 9.6 9.6 Selects the bit rate for the COM p ort. (Communication Port Rate) 14.4 14.4 por t . 19.2 19.2 38.4 38.4 Char Length: 7 7 Selects the character length for the Char Length: 8 8 Se ...

  • Paradyne 3161 DSU - page 16

    14 T able 7. User Configuration Options (3 of 3) Option Comments/Description Factory 2 Factory 1 5 5 TnDiscTm: ( T elnet Disconnect Up Up The period of inactivity (1 to 60 minutes ) that causes a (T e l ne t Di sconnec t T ime) Down Down 60 m i nu t es ) th a t causes a disconnect if TnInActTm is enabled. Save Save ena bl e d . T able 8. Alarm Conf ...

  • Paradyne 3161 DSU - page 17

    15 T able 8. Alarm Configuration Options (2 of 2) Option Comments/Description Factory 2 Factory 1 AlrmRelay: Enab Enab Specifies whether to activate the AlrmRelay: (Alarm Relay) Disab Disab Specifies whether to activate the alarm relay on an alarm condition. T able 9. General Management Configuration Options (1 of 2) Option Factory 1 Factory 2 Comm ...

  • Paradyne 3161 DSU - page 18

    16 T able 9. General Management Configuration Options (2 of 2) Option Comments/Description Factory 2 Factory 1 IP Adr: Edit Edit The IP address needed to access IP Adr: Clear Clear The IP address needed to access the device. NetMask: Edit Edit The Subnet Mask needed to NetMask: Clear Clear The Subnet Mask needed to access the device. Com IP Adr: Ed ...

  • Paradyne 3161 DSU - page 19

    17 T able 10. Management T rap Configuration Options Option Factory 1 Factory 2 Comments/Description Num T rap Mgrs: 1 2–6 1 2–6 The number of trap managers supported by the device. T rap n IP Adr: Edit Edit Specifies the IP address for each trap manager . This configuration T rap n IP Adr: Clear Clear trap manager . This configuration option i ...

Produzent Paradyne Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts Paradyne 3161 DSU erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Paradyne
- Bedienungsanleitungen 3161 DSU
- Produktkarten Paradyne
- Informationsbroschüren
- oder Energieetiketten Paradyne 3161 DSU
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Paradyne 3161 DSU.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Paradyne 3161 DSU, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Paradyne 3161 DSU. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Paradyne 3161 DSU ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Paradyne 3161 DSU, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Paradyne 3161 DSU hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Paradyne 3161 DSU verständlich ist.

Eine gänzliche Bedienungsanleitung von Paradyne sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Paradyne 3161 DSU bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Paradyne 3161 DSU befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Paradyne 3161 DSU, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Paradyne 3161 DSU - die uns die ersten Schritte während der Nutzung von Paradyne 3161 DSU erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Paradyne 3161 DSU hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Paradyne 3161 DSU im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Paradyne 3161 DSU?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Paradyne 3161 DSU nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Paradyne 3161 DSU hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)