Manuale per l’uso Paradyne 3161 DSU

19 pagine 0.26 mb
Scarica

Vai alla pagina of 19

Summary
  • Paradyne 3161 DSU - page 1

    ACCULINK 3161 DSU/CSU QUICK REFERENCE Document No. 3161-A2-GL1 1-40 ...

  • Paradyne 3161 DSU - page 2

    Copyright  1998 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law . No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, m ...

  • Paradyne 3161 DSU - page 3

    TM 1 ACCULINK 3161 DSU/CSU Quick Reference Document Number 3161-A2-GL1 1-40 February 1998 Quick Start Procedur e The following procedure is for experienced DSU/CSU users who are familiar with the 3161 DSU/CSU installation process and have no special requirements for their application. See the ACCULINK 316x Data Service Unit/Channel Service Unit Ope ...

  • Paradyne 3161 DSU - page 4

    2 3. Attach the network cable to the Auxiliary Backplane using either a 50-pin cable or the T1 Network Interface Adapter . Connect the other end of the network cable to the connection provided by the telephone company . 496-14386-0 3 Auxiliary Backplane over Slots 9–16 COMSPHERE 3000 Series Carrier (Rear) T1 Network Cable Cable Retainer 4. T urn ...

  • Paradyne 3161 DSU - page 5

    3 5. Insert the DSU/CSU circuit card into the appropriate slot in the carrier . The power-up self-test begins. 495-1479 7 6. If you intend to use front panel emulation, connect the cable from the PC to Port 2 on the Auxiliary Backplane using the COM port adapter and COM-port-to-PC cable. 7. If you do not intend to use the DTE Drop/Insert T1 port, d ...

  • Paradyne 3161 DSU - page 6

    4 Configuration Options Configuration options are accessed from the Cnfig branch of the front panel menu. DSU ESF Stat 97-15577 Dev HS S T est Pe r f TS t a t LE D ID T1 Prtn Pr tn User T elco Cur 24T ot Intvl Far Near Cur 8T ot Intvl T est R lpbk Lpbk Pt rn s La mp QRSS 51 1 Abort Mon LLBUP LLBDN 54UP 54DN FT1UP FT1DN PLB DLB RLB LLB Abort DCLB DT ...

  • Paradyne 3161 DSU - page 7

    5 T able 1. DTE Interface Configuration Options Option Factory 1 Factory 2 Comments/Description DTE Port: Enab Enab Enables the use of the DTE DTE Port: Disab Disab Enables the use of the DTE Drop/Insert port. DTE Framing: D4 D4 Selects D4 or ESF framing format DTE Framing: ESF ESF Selects D4 or ESF framing format. DTE Coding: AMI AMI Selects AMI o ...

  • Paradyne 3161 DSU - page 8

    6 T able 2. Port Configuration Options (2 of 3) Option Comments/Description Factory 2 Factory 1 Disab Disab Port LB: DTLB DTLB Port-initiated Loopbacks, allows Loopbacks to be initiated through Port LB: DCLB DCLB p, Loopbacks to be initiated through the port by the external DTE. Both Both ep o b y ee e a Disab Disab All Ones: DTR DTR All ones sent ...

  • Paradyne 3161 DSU - page 9

    7 T able 2. Port Configuration Options (3 of 3) Option Comments/Description Factory 2 Factory 1 Far end: Disab Disab Specifies whether the device will maintain far end performance Far-end: Maint Maint p maintain far-end performance statistics. Mgmt Link: Enab Enab S p ecifies whether the EDL Mgmt Link: Disab Disab S pec ifi es w h e th er th e EDL ...

  • Paradyne 3161 DSU - page 10

    8 T able 4. DTE Drop/Insert Port Channel Configuration Options Line 1 Displays: Line 2 Displays: Meaning Comments/Description — Unassigned N1 N2 N3 ...... N24: D1, D2 ... D24 Channel assigned to this DTE channel Function key under the channel (N1, N2, etc.) selects the DTE channel to assi g n ( D1 , D2 , ... D24 , N1 N2 N3 ...... N24 : Prt1 Prt2 ...

  • Paradyne 3161 DSU - page 11

    9 T able 5. Data Port Channel Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description NET NET Assigns this port to channels on Assign T o: DTE DTE Assigns this port to channels on the Network or DSX-1 T1 interface, tt h t Assign T o: Prt n Prt n the Network or DSX 1 T1 interface, or to another port. Block Block Determines how ...

  • Paradyne 3161 DSU - page 12

    10 T able 5. Data Port Channel Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description Clear Clear Clears (unassigns) channels for this port. Start At: N1 (D1) N2 (D2) N3 (D3) N4 (D4) N5 (D5) N6 (D6) N7 (D7) N8 (D8) N9 (D9) N10 (D10) N1 1 (D1 1) N12 (D12) N13 (D13) N14 (D14) N15 (D15) N16 (D16) N17 (D17) N18 (D18) N19 (D19) N ...

  • Paradyne 3161 DSU - page 13

    11 T able 6. General Configuration Options Option Factory 1 Factory 2 Comments/Description Gen Y ellow: Enab Enab Y ellow alarm is g enerated b y the G en Y e ll ow: (Generate Y ellow) Disab Disab Y e ll ow a l arm i s genera t e d b y th e DSU/CSU on LOS, LOF , or AIS. NET NET DTE DTE Selects the clock source to be Clock Src: Prt1 Prt1 Selects the ...

  • Paradyne 3161 DSU - page 14

    12 T able 7. User Configuration Options (1 of 3) Option Factory 1 Factory 2 Comments/Description Self - T est: Enab Enab Allows bypass of self-test on Self-T est: Disab Disab Allows bypass of self - test on initialization. Dial - In: Enab Enab Controls whether dial-in access is Dial-In: Disab Disab Controls whether dial - in access is allowed. Pass ...

  • Paradyne 3161 DSU - page 15

    13 T able 7. User Configuration Options (2 of 3) Option Comments/Description Factory 2 Factory 1 1.2 1.2 2.4 2.4 Com Rate: 4.8 4.8 Com Rate: (Communication Port Rt) 9.6 9.6 Selects the bit rate for the COM p ort. (Communication Port Rate) 14.4 14.4 por t . 19.2 19.2 38.4 38.4 Char Length: 7 7 Selects the character length for the Char Length: 8 8 Se ...

  • Paradyne 3161 DSU - page 16

    14 T able 7. User Configuration Options (3 of 3) Option Comments/Description Factory 2 Factory 1 5 5 TnDiscTm: ( T elnet Disconnect Up Up The period of inactivity (1 to 60 minutes ) that causes a (T e l ne t Di sconnec t T ime) Down Down 60 m i nu t es ) th a t causes a disconnect if TnInActTm is enabled. Save Save ena bl e d . T able 8. Alarm Conf ...

  • Paradyne 3161 DSU - page 17

    15 T able 8. Alarm Configuration Options (2 of 2) Option Comments/Description Factory 2 Factory 1 AlrmRelay: Enab Enab Specifies whether to activate the AlrmRelay: (Alarm Relay) Disab Disab Specifies whether to activate the alarm relay on an alarm condition. T able 9. General Management Configuration Options (1 of 2) Option Factory 1 Factory 2 Comm ...

  • Paradyne 3161 DSU - page 18

    16 T able 9. General Management Configuration Options (2 of 2) Option Comments/Description Factory 2 Factory 1 IP Adr: Edit Edit The IP address needed to access IP Adr: Clear Clear The IP address needed to access the device. NetMask: Edit Edit The Subnet Mask needed to NetMask: Clear Clear The Subnet Mask needed to access the device. Com IP Adr: Ed ...

  • Paradyne 3161 DSU - page 19

    17 T able 10. Management T rap Configuration Options Option Factory 1 Factory 2 Comments/Description Num T rap Mgrs: 1 2–6 1 2–6 The number of trap managers supported by the device. T rap n IP Adr: Edit Edit Specifies the IP address for each trap manager . This configuration T rap n IP Adr: Clear Clear trap manager . This configuration option i ...

Fabbricante Paradyne Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoParadyne 3161 DSU possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Paradyne
- manuali per l’uso 3161 DSU
- schede prodotto Paradyne
- opuscoli
- o etichette energetiche Paradyne 3161 DSU
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Paradyne 3161 DSU.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Paradyne 3161 DSU, manuali di manutenzione, brevi manuali o manuali utente Paradyne 3161 DSU. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Paradyne 3161 DSU.

Manuali per l’uso simili

Manuale completo del dispositivo Paradyne 3161 DSU, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Paradyne 3161 DSU dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Paradyne 3161 DSU.

Il manuale per l’uso completo Paradyne, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Paradyne 3161 DSU - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Paradyne 3161 DSU, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Paradyne 3161 DSU che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Paradyne 3161 DSU - che ci dovrebbe aiutare nei primi passi durante l'uso Paradyne 3161 DSU
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Paradyne 3161 DSU
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Paradyne 3161 DSU in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Paradyne 3161 DSU?

Utilizza il modulo sottostante

Se non hai risolto il problema con Paradyne 3161 DSU con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Paradyne 3161 DSU è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine