  • KTI Networks KCD-400 Series - page 1

    -1- INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400 ...

  • KTI Networks KCD-400 Series - page 2

    -2- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documen- tation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without per- mission from KTI Networks Inc. KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from ...

  • KTI Networks KCD-400 Series - page 3

    -3- The information contained in this document is subject to change without prior notice. Copyright (C) All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. FCC NOTICE This device complies with Class B Part 15 the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful inte ...

  • KTI Networks KCD-400 Series - page 4

    -4- T a ble of Contents 1. Introduction ......................................................... 5 1.1 Features ........................................................................................ 6 1.2 Specifications ................................................................................ 7 1.3 Special Functions ...................... ...

  • KTI Networks KCD-400 Series - page 5

    -5- 1. Introduction The industrial 1000BASE-T to 1000BASE-X media converter series pro- vides industrial strength Ethernet copper-to-fiber media conversion, allow- ing for 1000Base-T-to-1000Base-X over multi-mode or optional single- mode fiber optical media. For industrial environment, the converters are designed with the follow- ing enhanced featu ...

  • KTI Networks KCD-400 Series - page 6

    -6- 1.1 Features • Gigabit copper to fiber conversion: 1000Base-T-to-1000Base-SX/LX over multimode or single-mode fiber • SFP design : For flexibility , a n SFP (Mini-GBIC) connector is provided for the fiber port to accommodate any type of SFP fiber transceiver when needed. • Support full wire speed copper to fiber conversion • Auto MDI/MD ...

  • KTI Networks KCD-400 Series - page 7

    -7- 1.2 Specifications This figure shows the important components of the converter: ...

  • KTI Networks KCD-400 Series - page 8

    -8- T wisted-Pair Interfa ce (Copper Por t) Connector Shielded RJ-45 Signal Compliance IEEE 802.3ab 1000BASE-T std. Pin Assignments Auto MDI/MDI-X detection Data Speed 1000Mbps Duplex Mode Half-duplex or Full-duplex Configuration Auto-negotiation support Ca ble T ypes Category 5 or higher UTP Link Distance Up to 100 meters Fiber Optic Interface (Fi ...

  • KTI Networks KCD-400 Series - page 9

    -9- DC Power Interface Interface Screw-type terminal block 1. T wo pairs for power wire ca sca ding 2. One pair for power failure relay output DC Jack (-D6.3mm/+D2.0mm) Operating Input V oltages +7V ~ +30V(+5%) Power c on s um ption 2.25W @+7.5VDC input 2.3W @+24VDC input 2.5W @+30VDC input Basic Information Conversion Full wire speed 1000Mbps - 1, ...

  • KTI Networks KCD-400 Series - page 10

    -10- Certificate F C C Part 15 Class B CE/EMC EMI EN50081-1 Class B EMS EN55024 CE/L V D Safe ty E N 60950 EN 50081-1/1992 : EN55022:1994/A1:1995/A2:1997 EN61000-3-2:2000 EN61000-3-3:1995/A1:2001 EN 55024:1998/A1:2001 IEC 61000-4-2:1995 ESD T est IEC 61000-4-3:1995 RS T est IEC 61000-4-4:1995 EFT/BURST T est IEC 61000-4-5:1995 Surge T est IEC 61000 ...

  • KTI Networks KCD-400 Series - page 11

    -11- 1.3 Special Functions Auto MDI/MDI-X Function This function allows the copper port to auto-detect the twisted-pair sig- nals and adapts itself to form a valid MDI to MDI-X connection with the remote connected device automatically . Link Fault Pass Through Function When a link fault is detected on the copper port, the device will force a link d ...

  • KTI Networks KCD-400 Series - page 12

    -12- Far End Fault Function The fiber port is facilitated with this function. When the fiber port detects a link failure on its receiving circuitry , it will send out a n FEFI (Far End Fault Indication) signal to the remote connected device to indicate a remote fault is detected. It also is capable to receive FEFI signal sent from the remote link p ...

  • KTI Networks KCD-400 Series - page 13

    -13- 2. Installation 2.1 Unpacking Check that the following components have been included: • Information CD • The Media Converter unit • DIN-rail mounting bracket If any item is found missing or damaged, please contact your local reseller for replacement. The following are available optional accessories: • Panel Mounting Bracket The bracket ...

  • KTI Networks KCD-400 Series - page 14

    -14- 2.2 Safety Cautions T o reduce the risk of bodily injury , electrical shock, fire, a nd da mage to the equipment, observe the following precautions. • Do not service any product except as explained in your system documentation. • Opening or removing covers may expose you to electrical shock. Only a trained service technician should service ...

  • KTI Networks KCD-400 Series - page 15

    -15- 2.3 DIN-Rail Mounting In the product package, a DIN-rail bracket is installed on the device for mounting the converter in a industrial DIN-rail enclosure. The steps to mount the device onto a DIN rail are: 1 . Install the mounting bracket onto the device unit as shown below: 2 . Attach bracket to the lower edge of the DIN rail and push the uni ...

  • KTI Networks KCD-400 Series - page 16

    -16- The final mechanical dimensions after installing DIN rail mounting bracket are: ...

  • KTI Networks KCD-400 Series - page 17

    -17- 2.4 Panel Mounting The device is provided with an optional panel mounting bracket. The bra cket support mounting the device on a pla ne surfa ce securely . The mounting steps are: 1 . Install the mounting bracket on the device unit. 2 . Screw the bracket on the device unit. 3 . Screw the device unit on a panel. 4 . Make sure that there are pro ...

  • KTI Networks KCD-400 Series - page 18

    -18- The screw locations and final dimension are shown below: ...

  • KTI Networks KCD-400 Series - page 19

    -19- 2.5 Applying Power The power specifications of the device are: Operating V oltage + 7 ~ +30VDC Power Consumption Max. 2.5W @30VDC The device provides two types of power interfaces, terminal block and DC power ja ck for rece iving DC power input from external power supply . Using T erminal Blocks Either DC1 interface or DC2 interface can be use ...

  • KTI Networks KCD-400 Series - page 20

    -20- Power wires: 24 ~ 12A W G (IEC 0.5~2.5mm 2 ) Install the power source wires with the plug properly . Screw the wire with plug securely . Then, plug in DC1 conta cts. If cascading the power to next device is needed, install the power wires and plug for another switch. Then, use DC2 contacts. Note: Only up to four device units can be cascaded to ...

  • KTI Networks KCD-400 Series - page 21

    -21- Using DC Power Jack DC Jack Connector: Jack D 6.3mm D 2.0mm AC Power Adapters: Optional commercial rated adapters are available for purchasing. Rated AC120V/60Hz DC7.5V 1A Rated AC230V/50Hz DC7.5V 1A Rated AC100V/50-60Hz DC7.5V 1A Rated AC240V/50Hz DC7.5V 1A Connect power adapter DC plug to the DC power jack of the converter before connecting ...

  • KTI Networks KCD-400 Series - page 22

    -22- 2.6 Power Failure Relay Output The device provides a relay output to report power failure event to a remote alarm monitoring system. The replay output is provided with two contacts labeled PF+ and PF- in the terminal block interface. Use the provided 2P terminal plug for signal wiring and plug into the PF+/ - contacts. The function is designed ...

  • KTI Networks KCD-400 Series - page 23

    -23- 2.7 Ma king T wisted Pair Copper Port Conne ction Copper port is featured to support connection to : • Auto-negotiation devices • Auto-negotiation incapable 10BASE-T devices • Auto-negotiation incapable 100BASE-TX devices Network Cables 1000BASE-T : 4-pair UTP Cat. 5e or 6, EIA/TIA-568B 100-ohm STP Link distance: Up to 100 meters Note: T ...

  • KTI Networks KCD-400 Series - page 24

    -24- 2.8 Making Fiber Port Connection The mini-GBIC (SFP) port must be installed with an SFP fiber trans- ceiver for making fiber connection. The device may come with an SFP tra nsceiver pre-installed when it is shi pped from factory . Installing SFP Fiber T ra nsceiver Turn off the power to the device. Insert the SFP fiber transceiver into the min ...

  • KTI Networks KCD-400 Series - page 25

    -25- 3 LED Indicators The following figure shows the locations of the configuration switches and LED indicators: 3.1 LED Indicators LED DISPLA Y ST A TE INTERPRET A TION P W R Power status O N The device is powered on. O F F The device is powered off. S F P SFP slot status O N An SFP transceiver is installed. O F F No SFP transceiver is installed. ...

  • KTI Networks KCD-400 Series - page 26

    -26- Appendix: Model Optical Specifications The media converter series provides the following fiber options: Model Specifications Reference Operating KCD-400-xx FX W avelength Fiber Dista nce T e mpera tur e -SX L C 850nm 50/125 MMF 500m -20 ~ 70 o C 62.5/125 MMF 200m - LX L C 1310nm MMF 550m -20 ~ 70 o C SMF 10km -LX20 L C 1310nm SMF 20km -20 ~ 70 ...

Produzent KTI Networks Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts KTI Networks KCD-400 Series erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen KTI Networks
- Bedienungsanleitungen KCD-400 Series
- Produktkarten KTI Networks
- Informationsbroschüren
- oder Energieetiketten KTI Networks KCD-400 Series
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung KTI Networks KCD-400 Series.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen KTI Networks KCD-400 Series, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen KTI Networks KCD-400 Series. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts KTI Networks KCD-400 Series ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts KTI Networks KCD-400 Series, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von KTI Networks KCD-400 Series hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von KTI Networks KCD-400 Series verständlich ist.

Eine gänzliche Bedienungsanleitung von KTI Networks sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von KTI Networks KCD-400 Series bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von KTI Networks KCD-400 Series befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich KTI Networks KCD-400 Series, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts KTI Networks KCD-400 Series - die uns die ersten Schritte während der Nutzung von KTI Networks KCD-400 Series erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit KTI Networks KCD-400 Series hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von KTI Networks KCD-400 Series im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich KTI Networks KCD-400 Series?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit KTI Networks KCD-400 Series nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit KTI Networks KCD-400 Series hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)