Bedienungsanleitung Blue Sea Systems P12

32 Seiten 7.17 mb
Download

Zur Seite of 32

Summary
  • Blue Sea Systems P12 - page 1

    Read and understand the contents of this User Manual. It contains impor tant safety , handling , and operational instr uctions for the P12 Batter y Chargers. This User Manual describes the product mentioned herein at the time of its publication. Specifications and performance are subject to change at the discretion of Blue Sea Systems. T o view th ...

  • Blue Sea Systems P12 - page 2

    ...

  • Blue Sea Systems P12 - page 3

    Specifications are subject to change. See bluesea.com/P12 for current information. 1 Important Safety Instr uctions 2 P12 Batter y Charger Over view 3–4 Specifications 5 Installation T ables 5 • T able A: Minimum Recommended Wire Size • T able B: Recommended DC Circuit Protection • T able C: T ypical AC Regional Wire Colors • T able D: ...

  • Blue Sea Systems P12 - page 4

    Specifications are subject to change. See bluesea.com/P12 for current information. IMPORT ANT SAFETY INSTR UCTIONS WARNING Refers to a potentially hazardous situation which, if not avoided, could result in death or serious injur y . CA UTION Refers to a potentially hazardous situation which, if not avoided, may result in injur y . WARNING The P12 ...

  • Blue Sea Systems P12 - page 5

    Specifications are subject to change. See bluesea.com/P12 for current information. The Blue Sea Systems P12 Batter y Charger is dr y mount device designed for use in marine applications and other harsh environments where reliability , ease of use, and high perfor mance are of primar y impor tance. T o this end, the P12 is designed, assembled, and ...

  • Blue Sea Systems P12 - page 6

    Specifications are subject to change. See bluesea.com/P12 for current information. − NEG Battery Bus + POS Battery 1 + POS Battery 2 + POS Battery 3 DC Output Max.T orque 75 in-lb (8.47 Nm) AGC® 10A AC Fuse DC Safety Ground Rugged, finned cast aluminum case F an vent Screen selection buttons Charging stage indicators T er mination cover latch C ...

  • Blue Sea Systems P12 - page 7

    Specifications are subject to change. See bluesea.com/P12 for current information. * Consult batter y manufacturer specifications for other batter y types to avoid damage. Do not mix batter y types. ** Battery bank sizes are recommended for optimal charging efficiency-see bluesea.com/P12 for details. Larger and smaller size banks could charge we ...

  • Blue Sea Systems P12 - page 8

    Specifications are subject to change. See bluesea.com/P12 for current information. 7.80" (198mm) T op mounting screw centers Ø0.3" (6.6mm) Mounting holes Clearance for : M6, 1/4", or #12 mounting hard- ware NOTE: Mounting holes are not symmetrical 11.18" (284mm) Mounting screw centers 13.00" (330.6mm) 7.40" (188mm) B ...

  • Blue Sea Systems P12 - page 9

    Specifications are subject to change. See bluesea.com/P12 for current information. Included Components P12 7521 AND 7522 BATTERY CHARGERS 7 7 1 3 4 7 8 6 5 9 Dielectric Grease 10 #12 x 1-1/4" sheet metal screws (Use #3 Phillips screwdriver) Used for T emperature Sensor and the Optional Accessor y P12 Remote Display Connections (see pages 24? ...

  • Blue Sea Systems P12 - page 10

    Specifications are subject to change. See bluesea.com/P12 for current information. 1. AC W ire (see T able D pag e 5) NOTE: Wire length must reach from the panel to the batter y charger AC Connections with proper routing, suppor t, drip loops, ser vice loops, and termination. NOTE: Y ellow is preferred for negative however diagrams are drawn in bl ...

  • Blue Sea Systems P12 - page 11

    Specifications are subject to change. See bluesea.com/P12 for current information. Installation Instr uctions DC AC Installation Steps 1. Before beginning electrical installation, disconnect all positive and negative AC and DC power sources. The P12 Batter y Charger default startup mode is “ User”. The batter y charg er will maintain a voltage ...

  • Blue Sea Systems P12 - page 12

    Specifications are subject to change. See bluesea.com/P12 for current information. DC Safety Ground Batter y 2 Batter y 3 Batter y 1 Line Neutral Ground AC Connections #8 (M4) Ring T er minals DC Connections 1/4" (M6) Ring T er minals Fuse Fuse Fuse T emperature Sense RJ11 Port Remote Displa y RJ45 Port Installation Instr uctions (continued) ...

  • Blue Sea Systems P12 - page 13

    Specifications are subject to change. See bluesea.com/P12 for current information. Initial Charg er Setup 11 During Initial Charg er Setup, or after resetting to factor y defaults, the following screens require user input to provide functional batter y charging . 1. Using the left or right arrow button, scroll to the desired language. Press the Se ...

  • Blue Sea Systems P12 - page 14

    Specifications are subject to change. See bluesea.com/P12 for current information. Adv anced Charg er Setup 1. Press the Menu button. 2. Press the left or right arrow buttons to scroll to the Fan Speed window 3. Press the Select button. 4. Press the up or down arrow buttons to select the desired speed. a. High: The fan will spin up to its maximum ...

  • Blue Sea Systems P12 - page 15

    Specifications are subject to change. See bluesea.com/P12 for current information. 2. Press the left or right arrow buttons to scroll to the Fan Speed window 3. Press the Select button. 4. Press the up or down arrow buttons to select the desired speed. a. High: The fan will spin up to its maximum speed. This is the recommended setting for optimal ...

  • Blue Sea Systems P12 - page 16

    Specifications are subject to change. See bluesea.com/P12 for current information. CA UTION The default Absorption T imer values are set to satisfy a majority of the batter y configurations that exist. Unwarranted changes to Absorption timer s could result in damage to the batteries and reduced batter y life. T o optimize Absor ption Timer based ...

  • Blue Sea Systems P12 - page 17

    Specifications are subject to change. See bluesea.com/P12 for current information. Minimum Charge T emper ature: The default is 0ºC The lowest temperature of the sensor in which the charger will continue charging. If the temperature sensor falls below the minimum charge temperature, the charger will enter standby mode, and cease to charge. T empe ...

  • Blue Sea Systems P12 - page 18

    Specifications are subject to change. See bluesea.com/P12 for current information. 16 6. Press “I Accept” to continue. 7. Using the batter y manufacturer’ s parameter s, input the correct equalization voltage, amperage, and time on the batter y bank you would like to equalize. You may only equalize one battery bank at a time. Equalization De ...

  • Blue Sea Systems P12 - page 19

    Specifications are subject to change. See bluesea.com/P12 for current information. 17 8. T o change batter y , use the up down ar row buttons to scroll the cursor to the Bat1 window . 9. Press the Select button. 10. Using the left and right arrow buttons, scroll between the three different battery banks connected to the charger. 11. Confirm Equal ...

  • Blue Sea Systems P12 - page 20

    Specifications are subject to change. See bluesea.com/P12 for current information. 18 Charg er Summar y The Charger Summary screen provides data of the batter y’ s status while the batter y charger is operational. Options: - Press the Histor y button to view previous charger performance - Press the Menu button to view the Configuration Menu How ...

  • Blue Sea Systems P12 - page 21

    Specifications are subject to change. See bluesea.com/P12 for current information. 19 T emperature P ar ameters The T emperature P arameters screen indicates the minimum and maximum operating temperature based on the temperature sensor. Read the T emperature Parameters section on page 15 before making any adjustments. Options: - Select Units and t ...

  • Blue Sea Systems P12 - page 22

    Specifications are subject to change. See bluesea.com/P12 for current information. 20 Aler t Screens and Diagnostics If at any time during the charg ers life the red Aler t light g oes on, then the charg er is not providing optimal performance. The below Aler ts encompass all of the possibilities for the charg er to under perfor m. Alerts will be ...

  • Blue Sea Systems P12 - page 23

    Specifications are subject to change. See bluesea.com/P12 for current information. 21 Aler t Screens and Diagnostics (continued) DC Output Voltag e T oo High If at any point the charger detects a DC output voltage greater than 17.8V DC for five seconds, then the aler t screen on the right will appear. In this state the charger will cease to charg ...

  • Blue Sea Systems P12 - page 24

    Specifications are subject to change. See bluesea.com/P12 for current information. Optional Installation SI-ACR and m -A CR Installation Instr uctions (PN 7610 and PN 7601) to Enable Start Isolation 1. Disconnect the DC Negative (Ground) wire going to the ACR. 2. If present, disconnect the Star t Isolation wire connected to ACR. 3. Connect a wire ...

  • Blue Sea Systems P12 - page 25

    Specifications are subject to change. See bluesea.com/P12 for current information. Optional Installation (continued) ML-ACR Installation Instructions (PN 7620 and PN 7622) to Enable Start Isolation* 1. Disconnect the black ground wire connected to the ML-ACR wire harness. 2. If present, disconnect all Star t Isolation wires connected to the Brown, ...

  • Blue Sea Systems P12 - page 26

    Specifications are subject to change. See bluesea.com/P12 for current information. P12 Batter y Charg er Remote Indicates batter y charger stag e, aler ts, and controls basic batter y charger functions LED Indicators • Charging: Quick check for green light confirms charging • Charge Stag e: Displays charging stage including PreFloat for each ...

  • Blue Sea Systems P12 - page 27

    Specifications are subject to change. See bluesea.com/P12 for current information. 1 2 3 4 5 6 Used for T emperature Sensor and Remote Display Connections. V iew the MSDS for the Dielectric Grease at bluesea.com/P12 #6 x 1 " pan-head sheet metal screws (#2 Phillips screwdriver) Recommended torque: 5–10 in-lb (0.6–1.1 Nm) 1. Four Mounting ...

  • Blue Sea Systems P12 - page 28

    Specifications are subject to change. See bluesea.com/P12 for current information. 1. Charging: SOLID ON (Green): Indicates Charging mode and will operate according to its charging stage. BLINKING (Green): T ransitioning from Standby to a Charging state. OFF: Standby mode - will not charge a batter y or supply current to loads. 2. Charge Stag e: B ...

  • Blue Sea Systems P12 - page 29

    Specifications are subject to change. See bluesea.com/P12 for current information. 5. Ther mal Re gulaton: SOLID ON (Y ellow): The charger temp output limit LED indicator will blink to notify the user that the charger is limiting its output to protect itself from eventual overheating. The most common correction for this state is to increase the fa ...

  • Blue Sea Systems P12 - page 30

    Specifications are subject to change. See bluesea.com/P12 for current information. 28 W ar r anty and Contact Infor mation 7520 1521 7610 7622 7700 5502 7720 Re gister your P12 Batter y Charg er at bluesea.com/w ar r anty Blue Sea Systems stands behind its products for as long as you own them. Blue Sea Systems will replace or issue a credit for an ...

  • Blue Sea Systems P12 - page 31

    Specifications are subject to change. See bluesea.com/P12 for current information. T win Engine 3 Batter y Bank 360 P anel System RBS RBS Starter Alternator Starter PowerBar (System Ground) Alternator House Start 1 Start 2 RBS ACRs LEGEND DC Positive AC Line System Ground Control Class- T Fuse Block 10 11 12 13 13 12 15 16 5 6 7 8 9 3 4 2 1 P12 Ba ...

  • Blue Sea Systems P12 - page 32

    425 Sequoia Drive Bellingham, W A 98226 USA p 360.738.8230 p 800.222.7617 USA and Canada Customer Service f 360.734.4195 conductor@bluesea.com www .bluesea.com 980012000 Rev . 005 ...

Produzent Blue Sea Systems Kategorie Battery Charger

Dokumente, die wir vom Produzenten des Geräts Blue Sea Systems P12 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Blue Sea Systems
- Bedienungsanleitungen P12
- Produktkarten Blue Sea Systems
- Informationsbroschüren
- oder Energieetiketten Blue Sea Systems P12
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Blue Sea Systems P12.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Blue Sea Systems P12, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Blue Sea Systems P12. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Blue Sea Systems P12 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Blue Sea Systems P12, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Blue Sea Systems P12 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Blue Sea Systems P12 verständlich ist.

Eine gänzliche Bedienungsanleitung von Blue Sea Systems sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Blue Sea Systems P12 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Blue Sea Systems P12 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Blue Sea Systems P12, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Blue Sea Systems P12 - die uns die ersten Schritte während der Nutzung von Blue Sea Systems P12 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Blue Sea Systems P12 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Blue Sea Systems P12 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Blue Sea Systems P12?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Blue Sea Systems P12 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Blue Sea Systems P12 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)