    Read and understand the contents of this User Manual. It contains impor tant safety , handling , and operational instr uctions for the P12 Batter y Chargers. This User Manual describes the product mentioned herein at the time of its publication. Specifications and performance are subject to change at the discretion of Blue Sea Systems. T o view th ...

  • Blue Sea Systems P12 - page 2

    ...

  • Blue Sea Systems P12 - page 3

    Specifications are subject to change. See bluesea.com/P12 for current information. 1 Important Safety Instr uctions 2 P12 Batter y Charger Over view 3–4 Specifications 5 Installation T ables 5 • T able A: Minimum Recommended Wire Size • T able B: Recommended DC Circuit Protection • T able C: T ypical AC Regional Wire Colors • T able D: ...

  • Blue Sea Systems P12 - page 4

    Specifications are subject to change. See bluesea.com/P12 for current information. IMPORT ANT SAFETY INSTR UCTIONS WARNING Refers to a potentially hazardous situation which, if not avoided, could result in death or serious injur y . CA UTION Refers to a potentially hazardous situation which, if not avoided, may result in injur y . WARNING The P12 ...

  • Blue Sea Systems P12 - page 5

    Specifications are subject to change. See bluesea.com/P12 for current information. The Blue Sea Systems P12 Batter y Charger is dr y mount device designed for use in marine applications and other harsh environments where reliability , ease of use, and high perfor mance are of primar y impor tance. T o this end, the P12 is designed, assembled, and ...

  • Blue Sea Systems P12 - page 6

    Specifications are subject to change. See bluesea.com/P12 for current information. − NEG Battery Bus + POS Battery 1 + POS Battery 2 + POS Battery 3 DC Output Max.T orque 75 in-lb (8.47 Nm) AGC® 10A AC Fuse DC Safety Ground Rugged, finned cast aluminum case F an vent Screen selection buttons Charging stage indicators T er mination cover latch C ...

  • Blue Sea Systems P12 - page 7

    Specifications are subject to change. See bluesea.com/P12 for current information. * Consult batter y manufacturer specifications for other batter y types to avoid damage. Do not mix batter y types. ** Battery bank sizes are recommended for optimal charging efficiency-see bluesea.com/P12 for details. Larger and smaller size banks could charge we ...

  • Blue Sea Systems P12 - page 8

    Specifications are subject to change. See bluesea.com/P12 for current information. 7.80" (198mm) T op mounting screw centers Ø0.3" (6.6mm) Mounting holes Clearance for : M6, 1/4", or #12 mounting hard- ware NOTE: Mounting holes are not symmetrical 11.18" (284mm) Mounting screw centers 13.00" (330.6mm) 7.40" (188mm) B ...

  • Blue Sea Systems P12 - page 9

    Specifications are subject to change. See bluesea.com/P12 for current information. Included Components P12 7521 AND 7522 BATTERY CHARGERS 7 7 1 3 4 7 8 6 5 9 Dielectric Grease 10 #12 x 1-1/4" sheet metal screws (Use #3 Phillips screwdriver) Used for T emperature Sensor and the Optional Accessor y P12 Remote Display Connections (see pages 24? ...

  • Blue Sea Systems P12 - page 10

    Specifications are subject to change. See bluesea.com/P12 for current information. 1. AC W ire (see T able D pag e 5) NOTE: Wire length must reach from the panel to the batter y charger AC Connections with proper routing, suppor t, drip loops, ser vice loops, and termination. NOTE: Y ellow is preferred for negative however diagrams are drawn in bl ...

  • Blue Sea Systems P12 - page 11

    Specifications are subject to change. See bluesea.com/P12 for current information. Installation Instr uctions DC AC Installation Steps 1. Before beginning electrical installation, disconnect all positive and negative AC and DC power sources. The P12 Batter y Charger default startup mode is “ User”. The batter y charg er will maintain a voltage ...

  • Blue Sea Systems P12 - page 12

    Specifications are subject to change. See bluesea.com/P12 for current information. DC Safety Ground Batter y 2 Batter y 3 Batter y 1 Line Neutral Ground AC Connections #8 (M4) Ring T er minals DC Connections 1/4" (M6) Ring T er minals Fuse Fuse Fuse T emperature Sense RJ11 Port Remote Displa y RJ45 Port Installation Instr uctions (continued) ...

  • Blue Sea Systems P12 - page 13

    Specifications are subject to change. See bluesea.com/P12 for current information. Initial Charg er Setup 11 During Initial Charg er Setup, or after resetting to factor y defaults, the following screens require user input to provide functional batter y charging . 1. Using the left or right arrow button, scroll to the desired language. Press the Se ...

  • Blue Sea Systems P12 - page 14

    Specifications are subject to change. See bluesea.com/P12 for current information. Adv anced Charg er Setup 1. Press the Menu button. 2. Press the left or right arrow buttons to scroll to the Fan Speed window 3. Press the Select button. 4. Press the up or down arrow buttons to select the desired speed. a. High: The fan will spin up to its maximum ...

  • Blue Sea Systems P12 - page 15

    Specifications are subject to change. See bluesea.com/P12 for current information. 2. Press the left or right arrow buttons to scroll to the Fan Speed window 3. Press the Select button. 4. Press the up or down arrow buttons to select the desired speed. a. High: The fan will spin up to its maximum speed. This is the recommended setting for optimal ...

  • Blue Sea Systems P12 - page 16

    Specifications are subject to change. See bluesea.com/P12 for current information. CA UTION The default Absorption T imer values are set to satisfy a majority of the batter y configurations that exist. Unwarranted changes to Absorption timer s could result in damage to the batteries and reduced batter y life. T o optimize Absor ption Timer based ...

  • Blue Sea Systems P12 - page 17

    Specifications are subject to change. See bluesea.com/P12 for current information. Minimum Charge T emper ature: The default is 0ºC The lowest temperature of the sensor in which the charger will continue charging. If the temperature sensor falls below the minimum charge temperature, the charger will enter standby mode, and cease to charge. T empe ...

  • Blue Sea Systems P12 - page 18

    Specifications are subject to change. See bluesea.com/P12 for current information. 16 6. Press “I Accept” to continue. 7. Using the batter y manufacturer’ s parameter s, input the correct equalization voltage, amperage, and time on the batter y bank you would like to equalize. You may only equalize one battery bank at a time. Equalization De ...

  • Blue Sea Systems P12 - page 19

    Specifications are subject to change. See bluesea.com/P12 for current information. 17 8. T o change batter y , use the up down ar row buttons to scroll the cursor to the Bat1 window . 9. Press the Select button. 10. Using the left and right arrow buttons, scroll between the three different battery banks connected to the charger. 11. Confirm Equal ...

  • Blue Sea Systems P12 - page 20

    Specifications are subject to change. See bluesea.com/P12 for current information. 18 Charg er Summar y The Charger Summary screen provides data of the batter y’ s status while the batter y charger is operational. Options: - Press the Histor y button to view previous charger performance - Press the Menu button to view the Configuration Menu How ...

  • Blue Sea Systems P12 - page 21

    Specifications are subject to change. See bluesea.com/P12 for current information. 19 T emperature P ar ameters The T emperature P arameters screen indicates the minimum and maximum operating temperature based on the temperature sensor. Read the T emperature Parameters section on page 15 before making any adjustments. Options: - Select Units and t ...

  • Blue Sea Systems P12 - page 22

    Specifications are subject to change. See bluesea.com/P12 for current information. 20 Aler t Screens and Diagnostics If at any time during the charg ers life the red Aler t light g oes on, then the charg er is not providing optimal performance. The below Aler ts encompass all of the possibilities for the charg er to under perfor m. Alerts will be ...

  • Blue Sea Systems P12 - page 23

    Specifications are subject to change. See bluesea.com/P12 for current information. 21 Aler t Screens and Diagnostics (continued) DC Output Voltag e T oo High If at any point the charger detects a DC output voltage greater than 17.8V DC for five seconds, then the aler t screen on the right will appear. In this state the charger will cease to charg ...

  • Blue Sea Systems P12 - page 24

    Specifications are subject to change. See bluesea.com/P12 for current information. Optional Installation SI-ACR and m -A CR Installation Instr uctions (PN 7610 and PN 7601) to Enable Start Isolation 1. Disconnect the DC Negative (Ground) wire going to the ACR. 2. If present, disconnect the Star t Isolation wire connected to ACR. 3. Connect a wire ...

  • Blue Sea Systems P12 - page 25

    Specifications are subject to change. See bluesea.com/P12 for current information. Optional Installation (continued) ML-ACR Installation Instructions (PN 7620 and PN 7622) to Enable Start Isolation* 1. Disconnect the black ground wire connected to the ML-ACR wire harness. 2. If present, disconnect all Star t Isolation wires connected to the Brown, ...

  • Blue Sea Systems P12 - page 26

    Specifications are subject to change. See bluesea.com/P12 for current information. P12 Batter y Charg er Remote Indicates batter y charger stag e, aler ts, and controls basic batter y charger functions LED Indicators • Charging: Quick check for green light confirms charging • Charge Stag e: Displays charging stage including PreFloat for each ...

  • Blue Sea Systems P12 - page 27

    Specifications are subject to change. See bluesea.com/P12 for current information. 1 2 3 4 5 6 Used for T emperature Sensor and Remote Display Connections. V iew the MSDS for the Dielectric Grease at bluesea.com/P12 #6 x 1 " pan-head sheet metal screws (#2 Phillips screwdriver) Recommended torque: 5–10 in-lb (0.6–1.1 Nm) 1. Four Mounting ...

  • Blue Sea Systems P12 - page 28

    Specifications are subject to change. See bluesea.com/P12 for current information. 1. Charging: SOLID ON (Green): Indicates Charging mode and will operate according to its charging stage. BLINKING (Green): T ransitioning from Standby to a Charging state. OFF: Standby mode - will not charge a batter y or supply current to loads. 2. Charge Stag e: B ...

  • Blue Sea Systems P12 - page 29

    Specifications are subject to change. See bluesea.com/P12 for current information. 5. Ther mal Re gulaton: SOLID ON (Y ellow): The charger temp output limit LED indicator will blink to notify the user that the charger is limiting its output to protect itself from eventual overheating. The most common correction for this state is to increase the fa ...

  • Blue Sea Systems P12 - page 30

    Specifications are subject to change. See bluesea.com/P12 for current information. 28 W ar r anty and Contact Infor mation 7520 1521 7610 7622 7700 5502 7720 Re gister your P12 Batter y Charg er at bluesea.com/w ar r anty Blue Sea Systems stands behind its products for as long as you own them. Blue Sea Systems will replace or issue a credit for an ...

  • Blue Sea Systems P12 - page 31

    Specifications are subject to change. See bluesea.com/P12 for current information. T win Engine 3 Batter y Bank 360 P anel System RBS RBS Starter Alternator Starter PowerBar (System Ground) Alternator House Start 1 Start 2 RBS ACRs LEGEND DC Positive AC Line System Ground Control Class- T Fuse Block 10 11 12 13 13 12 15 16 5 6 7 8 9 3 4 2 1 P12 Ba ...

  • Blue Sea Systems P12 - page 32

    425 Sequoia Drive Bellingham, W A 98226 USA p 360.738.8230 p 800.222.7617 USA and Canada Customer Service f 360.734.4195 conductor@bluesea.com www .bluesea.com 980012000 Rev . 005 ...

Fabricant Blue Sea Systems Catégorie Battery Charger

Les documents que nous recevons du fabricant de l'appareilBlue Sea Systems P12 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Blue Sea Systems
- manuels d’utilisations P12
- fiches produit Blue Sea Systems
- dépliants
- ou étiquettes-énergie Blue Sea Systems P12
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Blue Sea Systems P12.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Blue Sea Systems P12, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Blue Sea Systems P12. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Blue Sea Systems P12.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Blue Sea Systems P12, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Blue Sea Systems P12 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Blue Sea Systems P12.

Le manuel d’utilisation complet Blue Sea Systems, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Blue Sea Systems P12 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Blue Sea Systems P12, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBlue Sea Systems P12 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Blue Sea Systems P12 - qui devraient nous aider dans les premières étapes lors de l'utilisation Blue Sea Systems P12
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Blue Sea Systems P12
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Blue Sea Systems P12 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Blue Sea Systems P12?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Blue Sea Systems P12, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Blue Sea Systems P12 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)