Bedienungsanleitung Graham Field AQ1000/AQ2000

16 Seiten 0.35 mb
Download

Zur Seite of 16

Summary
  • Graham Field AQ1000/AQ2000 - page 1

    AQ1000 / AQ2000 AL TERNA TING PRESSURE BUBBLE P AD AND PUMP SYSTEM USER MANUAL Impor tant: Do not operate the Mattress System without rst reading and understanding this manual! Save this manual for future use. The latest version of this manual can be found online at www.grahameld.com. AQ1000-INS-LAB-RevC1 1 ...

  • Graham Field AQ1000/AQ2000 - page 2

    2 AQ1000-INS-LAB-RevC11 CONTENTS INTRODUCTION..................................................................................... 3 INTENDEDUSEOFTHISDEVICE ........................................................ 3 CONTRAINDICA TION ...................................................................... 3 DANGER ......... ...

  • Graham Field AQ1000/AQ2000 - page 3

    AQ1000-INS-LAB-RevC11 3 INTRODUCTION Use this manual for setup and operation of the Lumex AQ1000 / AQ2000 Alternating Pr essur e Pad and Pump System. Read all instructions befor e using the pad and pump system. Save this manual for futur e r eference. INTENDED USE OF THIS DEVICE The intended use of the Alternating Pr essur e Pad and Pump System, ...

  • Graham Field AQ1000/AQ2000 - page 4

    4 AQ1000-INS-LAB-RevC11  CAUTION:Indicatesapotentialhazardorunsafe practicethat,ifnotavoided,couldresultinminoror moderatepersonalinjury . s  NOTICE:Indicatesapotentialhazardorunsafepractice that,ifnotavoided,couldresultinproductorpr ...

  • Graham Field AQ1000/AQ2000 - page 5

    AQ1000-INS-LAB-RevC11 5  W ARNING:Neveroperatethisproductif a) ithasadamagedcordorplug. b) itisnotworkingproperly . c) ithasbeendroppedordamaged. d) ithasbeendroppedintowater .  ReturntheproducttoyourGraham-Fieldequipment ...

  • Graham Field AQ1000/AQ2000 - page 6

    6 AQ1000-INS-LAB-RevC11 EQUIPMENT SYMBOLS Attention! Consult accompanying documents (this manual) “BF”symbol: Indicates that this product is in accordance with the degree of protection against electric shock for type BF equipment Grounding terminal Class II (for UL only) Disposal of Electrical & Electronic Equipment (WEEE): Do not treat ...

  • Graham Field AQ1000/AQ2000 - page 7

    AQ1000-INS-LAB-RevC11 7 PRODUCT DESCRIPTION B UBBLE P AD AND PUMP SY STEM bubble pad and pump system air tubes bubble pad pump PUMP pump (AQ2000 shown) front panel wire hangers fuses (220V only) air tube connectors ...

  • Graham Field AQ1000/AQ2000 - page 8

    8 AQ1000-INS-LAB-RevC11 FRONT P ANEL AQ1000 AQ1000 pump front panel ON/OFF switch air tube connectors AQ2000 AQ2000 pump front panel ON/OFF switch pressur e control dial Fr ont panel pr essur e contr ol dial (AQ2000 only) : The pr essur e control dial contr ols the air pr essure output. T o incr ease pr essure, turn the dial clockwise. T o decr ...

  • Graham Field AQ1000/AQ2000 - page 9

    AQ1000-INS-LAB-RevC11 9 INST ALLA TION UNP A CKING 1. Befor e unpacking, check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field equipment pr ovider . 2. Remove all loose packing fr om the carton. 3. Car efully r emove all components from the carton. 4. Inspect all components. ...

  • Graham Field AQ1000/AQ2000 - page 10

    10 AQ1000-INS-LAB-RevC11 5. Connect one end of the air tubes to the bubble pad: slide the ends of the air tubes over the connectors on the top of the foot end of the bubble pad. 6. Connect the other end of the air tubes to the pump connectors; ensur e that the ends of the air tubes ar e rmly tted over the bubble pad and pump connectors bef ...

  • Graham Field AQ1000/AQ2000 - page 11

    AQ1000-INS-LAB-RevC11 11 OPERA TION 1. T urn the ON/OFF switch to the ON position. The pump will begin to deliver air into the bubble pad. 2. Replace all sheets, blankets, and pillows on the bed. Info: if the pressure level seems low , check for any leakage in the air tubes or bubble pad. Replace any damaged tubes. If necessar y , contact your G ...

  • Graham Field AQ1000/AQ2000 - page 12

    12 AQ1000-INS-LAB-RevC11 MAINTENANCE CLEANING Perform the following cleaning pr ocedur es before use and as necessar y thereafter . Pump W ipe the pump with a clean, damp cloth and mild deter gent, and keep it away from dust. Air dr y . s  NOTICE:Donotusephenolicproductsorcorrosiveor powderedcleanserstoclea ...

  • Graham Field AQ1000/AQ2000 - page 13

    AQ1000-INS-LAB-RevC11 13 Fuse replacement (220V system onl y) tool needed: small screwdriver 1. If you suspect a blown fuse, disconnect the plug fr om the wall outlet immediately . fuse location fuse fuse cover 2. Use a small scr ewdriver to r emove the cover of the fuse holder (fuse locations ar e shown in pictur e above). 3. Insert a new fuse ...

  • Graham Field AQ1000/AQ2000 - page 14

    14 AQ1000-INS-LAB-RevC11 SPECIFICA TIONS Model AQ1000 (Standard) AQ2000 (Delux e) P ow er Supply 120V : 120V AC, 60 Hz, 1A 220V : 230V AC, 50 Hz, 7W Fuse Rating 120V : N/A 220V : T1A, 250V Pressur e 1.9 psi (13.10 kPa) 1.0 - 2.0 psi (6.89-13.79 kPa) Air Output 120V : 4.5 LPM 120V : 4-5 LPM 220V : 5.0 LPM 220V : 5-6 LPM Cyc le Time 120V : 5 min. ...

  • Graham Field AQ1000/AQ2000 - page 15

    AQ1000-INS-LAB-RevC11 15 WARRANTY GF Health Pr oducts, Inc. warrants the Lumex AQ1000 / AQ2000 Alternating Pr essur e Pad and Pump System for defects in workmanship and materials for the terms listed below . Pump: one year Pad: 90 days If a pr oduct is deemed to be under warranty , GF Health Pr oducts, Inc. shall pr ovide, at its option, (1) r e ...

  • Graham Field AQ1000/AQ2000 - page 16

    USA, Corporate Headquar ters: GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 telephone: 770-368-4700 fax: 770-368-2386 www .grahamfield.com AQ1000-INS-LAB-RevC11 © 2011, GF Health Products, Inc. ...

Produzent Graham Field Kategorie Camping Equipment

Dokumente, die wir vom Produzenten des Geräts Graham Field AQ1000/AQ2000 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Graham Field
- Bedienungsanleitungen AQ1000/AQ2000
- Produktkarten Graham Field
- Informationsbroschüren
- oder Energieetiketten Graham Field AQ1000/AQ2000
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Graham Field AQ1000/AQ2000.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Graham Field AQ1000/AQ2000, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Graham Field AQ1000/AQ2000. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Graham Field AQ1000/AQ2000 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Graham Field AQ1000/AQ2000, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Graham Field AQ1000/AQ2000 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Graham Field AQ1000/AQ2000 verständlich ist.

Eine gänzliche Bedienungsanleitung von Graham Field sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Graham Field AQ1000/AQ2000 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Graham Field AQ1000/AQ2000 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Graham Field AQ1000/AQ2000, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Graham Field AQ1000/AQ2000 - die uns die ersten Schritte während der Nutzung von Graham Field AQ1000/AQ2000 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Graham Field AQ1000/AQ2000 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Graham Field AQ1000/AQ2000 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Graham Field AQ1000/AQ2000?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Graham Field AQ1000/AQ2000 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Graham Field AQ1000/AQ2000 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen