Bedienungsanleitung Sterilite S12Q

12 Seiten 0.32 mb
Download

Zur Seite of 12

Summary
  • Sterilite S12Q - page 1

    Installation Instructions & Owner’ s Manual P/N 520022 January 2005 425 Clair Road W est, P .O. Box 1719 • Guelph, ON • N1H 7X4 • Canada t. 519.763.1032 • f. 519.763.5069 • t.f. 1.800.265.7246 e. water@r -can.com • i. www .r-can.com S12Q, S12Q-GOLD, S24Q, S24Q-GOLD, S40Q EP A # 57987-CN-001 ...

  • Sterilite S12Q - page 2

    T ABLE OF C ONTENTS : Safety Instructions Page 1 Improved Ballast Features Page 1 W ater Chemistry Page 2 Installing Y our Disinfection System Page 2 Operating & Maintenance Instructions Page 3-4 W arning Systems Page 4-5 W arranty Page 5 T roubleshooting Page 6-8 Parts Page 9 Specifications Page 10 S YMBOLS : Caution Protective Ground Electric ...

  • Sterilite S12Q - page 3

    1 S AFETY I NSTRUCTIONS : I MPROVED B ALLAST F EA TURES : W ARNING - to guard against injur y , basic safety precautions should be obser ved, including the following: 1 . R EAD AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. CAUTION - Disconnect power before servicing. 3. DANGER - T o avoid possible electric shock, special care should be taken since water i ...

  • Sterilite S12Q - page 4

    2 I NST ALLING Y OUR D ISINFECTION S YSTEM : • The complete water system, including any pressure or hot water tanks, must be sterilized before start up by flushing with chlorine (household bleach) to destroy any residual contamination. • The disinfection system should be connected to a ground fault interrupter . • The disinfection system is i ...

  • Sterilite S12Q - page 5

    3 O PERA TING & M AINTENANCE I NSTRUCTIONS : • Always disconnect power before performing any work on the ultraviolet disinfection system. • Regularly inspect your disinfection system unit to ensure that the UV light is still glowing and that its LED indicator is still glowing green. • Replace the UV lamp annually ( or biennially if season ...

  • Sterilite S12Q - page 6

    4 f) Re-assemble the quartz sleeve with spring in the UV chamber allowing the sleeve to protrude an equal d istance from both ends of the UV chamber . g) W et the o-rings and slide onto each end of the quartz sleeve and reassemble the gland nuts (hand tight is sufficient). h) Re-tighten all connections, turn on water and check for leaks. I) Re-inst ...

  • Sterilite S12Q - page 7

    5 into existing plumbing (1” for 12 & 24 gpm models). Install “normally-closed” solenoid valve within three (3) feet of d isinfection system. Remove the screws on the left and right side of the front aluminum panel allowing this panel to swing open. Remove the circuit board cover plate to expose the cir cuit board. Remove the round, black ...

  • Sterilite S12Q - page 8

    6 TROUBLESHOOTING GUIDE Caution: When performing any work on the disinfection system unplug the unit first and never look directly at the b urning UV lamp. SYMPTOM POSSIBLE CAUSES REMEDY PRESSURE DROP • the sediment pre-filter is clogged • replace filter cartridge with appropriate five micron cartridge, Note: check source water supply as fluctu ...

  • Sterilite S12Q - page 9

    7 S12Q TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS LAMP ST A TUS (GREEN LED) AUDIBLE ALARM UV LAMP ON OFF ON • Correct operating conditions, unit is functioning properly . OFF ON OFF • The UV lamp is spent, requires replacement lamp. • UV lamp not connected to power source. Check connection and reconnect lamp. • Ballast has switched off. ...

  • Sterilite S12Q - page 10

    8 S12Q-GOLD & S24Q-GOLD TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS UV INTENSITY (LED) AUDIBLE ALARM UV LAMP GREEN OFF ON • Correct operating conditions unit is functioning properly . YELLOW OFF ON • System performance has declined due to stained or dirty quartz sleeve and or sensor lens, or the lamp is beyond its useful life. • Clean s ...

  • Sterilite S12Q - page 11

    9 S12Q P ARTS BREAKDOWN S 36RL UV LAMP Q S-012 QUARTZ SLEEVE OR-212 O RING BA-ICE-3F BALLAST (100-130V/50-60Hz. or 200-250V/50-60Hz.) S UB-WH/LED512 LED INDICA TOR ASSEMBL Y RN-001 RET AINING NUT CS-001/Q CORD SET (120V .) CS-EU/Q EUROPEAN “SCHUKO” CORD SET (230V .) DP750 RET AINING NUT PLUG SP-3/8 3/8” DRAIN PLUG SP008 QUARTZ SLEEVE SPRING S ...

  • Sterilite S12Q - page 12

    10 SPECIFICA TIONS MODEL S12Q S12Q-GOLD S24Q S24Q-GOLD S40Q US Public Health 16 mJ/cm 2 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 3 67.2 lpm (97 gpm) ( 22.0 m 3 / Hr .) R-Can Standard 30 mJ/cm 2 56.8 lpm (15 gpm) (3.4 m 3 /Hr .) 56.8 lpm ...

Produzent Sterilite Kategorie Baby Accessories

Dokumente, die wir vom Produzenten des Geräts Sterilite S12Q erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Sterilite
- Bedienungsanleitungen S12Q
- Produktkarten Sterilite
- Informationsbroschüren
- oder Energieetiketten Sterilite S12Q
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Sterilite S12Q.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Sterilite S12Q, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Sterilite S12Q. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Sterilite S12Q ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Sterilite S12Q, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Sterilite S12Q hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Sterilite S12Q verständlich ist.

Eine gänzliche Bedienungsanleitung von Sterilite sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Sterilite S12Q bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Sterilite S12Q befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Sterilite S12Q, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Sterilite S12Q - die uns die ersten Schritte während der Nutzung von Sterilite S12Q erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Sterilite S12Q hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Sterilite S12Q im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Sterilite S12Q?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Sterilite S12Q nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Sterilite S12Q hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)