    Installation Instructions & Owner’ s Manual P/N 520022 January 2005 425 Clair Road W est, P .O. Box 1719 • Guelph, ON • N1H 7X4 • Canada t. 519.763.1032 • f. 519.763.5069 • t.f. 1.800.265.7246 e. water@r -can.com • i. www .r-can.com S12Q, S12Q-GOLD, S24Q, S24Q-GOLD, S40Q EP A # 57987-CN-001 ...

  • Sterilite S12Q - page 2

    T ABLE OF C ONTENTS : Safety Instructions Page 1 Improved Ballast Features Page 1 W ater Chemistry Page 2 Installing Y our Disinfection System Page 2 Operating & Maintenance Instructions Page 3-4 W arning Systems Page 4-5 W arranty Page 5 T roubleshooting Page 6-8 Parts Page 9 Specifications Page 10 S YMBOLS : Caution Protective Ground Electric ...

  • Sterilite S12Q - page 3

    1 S AFETY I NSTRUCTIONS : I MPROVED B ALLAST F EA TURES : W ARNING - to guard against injur y , basic safety precautions should be obser ved, including the following: 1 . R EAD AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. CAUTION - Disconnect power before servicing. 3. DANGER - T o avoid possible electric shock, special care should be taken since water i ...

  • Sterilite S12Q - page 4

    2 I NST ALLING Y OUR D ISINFECTION S YSTEM : • The complete water system, including any pressure or hot water tanks, must be sterilized before start up by flushing with chlorine (household bleach) to destroy any residual contamination. • The disinfection system should be connected to a ground fault interrupter . • The disinfection system is i ...

  • Sterilite S12Q - page 5

    3 O PERA TING & M AINTENANCE I NSTRUCTIONS : • Always disconnect power before performing any work on the ultraviolet disinfection system. • Regularly inspect your disinfection system unit to ensure that the UV light is still glowing and that its LED indicator is still glowing green. • Replace the UV lamp annually ( or biennially if season ...

  • Sterilite S12Q - page 6

    4 f) Re-assemble the quartz sleeve with spring in the UV chamber allowing the sleeve to protrude an equal d istance from both ends of the UV chamber . g) W et the o-rings and slide onto each end of the quartz sleeve and reassemble the gland nuts (hand tight is sufficient). h) Re-tighten all connections, turn on water and check for leaks. I) Re-inst ...

  • Sterilite S12Q - page 7

    5 into existing plumbing (1” for 12 & 24 gpm models). Install “normally-closed” solenoid valve within three (3) feet of d isinfection system. Remove the screws on the left and right side of the front aluminum panel allowing this panel to swing open. Remove the circuit board cover plate to expose the cir cuit board. Remove the round, black ...

  • Sterilite S12Q - page 8

    6 TROUBLESHOOTING GUIDE Caution: When performing any work on the disinfection system unplug the unit first and never look directly at the b urning UV lamp. SYMPTOM POSSIBLE CAUSES REMEDY PRESSURE DROP • the sediment pre-filter is clogged • replace filter cartridge with appropriate five micron cartridge, Note: check source water supply as fluctu ...

  • Sterilite S12Q - page 9

    7 S12Q TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS LAMP ST A TUS (GREEN LED) AUDIBLE ALARM UV LAMP ON OFF ON • Correct operating conditions, unit is functioning properly . OFF ON OFF • The UV lamp is spent, requires replacement lamp. • UV lamp not connected to power source. Check connection and reconnect lamp. • Ballast has switched off. ...

  • Sterilite S12Q - page 10

    8 S12Q-GOLD & S24Q-GOLD TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS UV INTENSITY (LED) AUDIBLE ALARM UV LAMP GREEN OFF ON • Correct operating conditions unit is functioning properly . YELLOW OFF ON • System performance has declined due to stained or dirty quartz sleeve and or sensor lens, or the lamp is beyond its useful life. • Clean s ...

  • Sterilite S12Q - page 11

    9 S12Q P ARTS BREAKDOWN S 36RL UV LAMP Q S-012 QUARTZ SLEEVE OR-212 O RING BA-ICE-3F BALLAST (100-130V/50-60Hz. or 200-250V/50-60Hz.) S UB-WH/LED512 LED INDICA TOR ASSEMBL Y RN-001 RET AINING NUT CS-001/Q CORD SET (120V .) CS-EU/Q EUROPEAN “SCHUKO” CORD SET (230V .) DP750 RET AINING NUT PLUG SP-3/8 3/8” DRAIN PLUG SP008 QUARTZ SLEEVE SPRING S ...

  • Sterilite S12Q - page 12

    10 SPECIFICA TIONS MODEL S12Q S12Q-GOLD S24Q S24Q-GOLD S40Q US Public Health 16 mJ/cm 2 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 3 67.2 lpm (97 gpm) ( 22.0 m 3 / Hr .) R-Can Standard 30 mJ/cm 2 56.8 lpm (15 gpm) (3.4 m 3 /Hr .) 56.8 lpm ...

Fabricant Sterilite Catégorie Baby Accessories

Les documents que nous recevons du fabricant de l'appareilSterilite S12Q peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Sterilite
- manuels d’utilisations S12Q
- fiches produit Sterilite
- dépliants
- ou étiquettes-énergie Sterilite S12Q
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Sterilite S12Q.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Sterilite S12Q, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Sterilite S12Q. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Sterilite S12Q.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Sterilite S12Q, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Sterilite S12Q par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Sterilite S12Q.

Le manuel d’utilisation complet Sterilite, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Sterilite S12Q - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Sterilite S12Q, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSterilite S12Q qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Sterilite S12Q - qui devraient nous aider dans les premières étapes lors de l'utilisation Sterilite S12Q
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Sterilite S12Q
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Sterilite S12Q dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Sterilite S12Q?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Sterilite S12Q, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Sterilite S12Q il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)