Bedienungsanleitung Vector SMATE200A

14 Seiten 0.44 mb
Download

Zur Seite of 14

Summary
  • Vector SMATE200A - page 1

    Vector Signal Generator ¸SMATE 200A Configuration Guide Version 01.00 April 2005 ...

  • Vector SMATE200A - page 2

    The variety of signal generation for production This document guides you step -by-step throug h th e configuration proc ed ure for the Vector Signal Generato r R&S SMATE200A. Each step indicates wheth e r an option is mandatory or optio n al and also provides the follo wing information: Option Name of the option Description Description of the o ...

  • Vector SMATE200A - page 3

    Option overview RF path B RF path A Base Unit 100 kHz to 6 GH z 1st RF Path SMATE-B106 1401.1200.02 Vector Signal Generator SMATE200A 1400.7005.02 Baseband Options marked with 2x (first in baseband path can be in- stalled twice A, second in baseband path B) High Power Output 1st RF Path SMATE-B31 1401.1800.02 FM/PhiM Modulator and Low Phase Noise S ...

  • Vector SMATE200A - page 4

    Single-path instrument Applies if t he instrument i s equipped with o ne RF path and no more than one baseband pa th. Step c Configure RF path MANDATORY Choose frequency range (only one choice possible) MANDATORY Option Description Requires Not compatible with HW or SW Remarks SMATEB103 100 kHz to 3 GHz SMATE200A SMATEB106 HW Factory-install ed SMA ...

  • Vector SMATE200A - page 5

    Choose digital modulation systems with R&S WinIQSIM ™ 1 OPTIONAL Option Description Requires Not compatible with HW or SW Remarks SMATE-K11 Dig. Std. IS-95 SMATE -B 1 0 o r B11 - SW Wit h Wi n IQS I M ™ SMATE-K12 Dig. Std. cdma20 00 SMATE-B10 or B11 - SW Wit h Wi n IQS I M ™ SMATE-K13 Dig. Std. 3GPP TD D SMATE-B10 or B11 - SW Wit h Wi n I ...

  • Vector SMATE200A - page 6

    Two-path instrument Applies if t he instrument is equipped with up to two RF paths and up to t wo baseband paths. Step c Configure RF path A MANDATORY Choose frequency range (only one choice possible) MANDATORY Option Description Requires Not compatible with HW or SW Remarks SMATEB103 100 kHz to 3 GHz SMATE200A SMATEB106 HW Factory-install ed SMATE ...

  • Vector SMATE200A - page 7

    Step e Configure baseband path A OPTIONAL Choose baseband source MANDATORY Option Description Requires Not compatible with HW or SW Remarks SMATE-B13 Baseband Main Module SMATEB10x - HW Factory-install ed. Requires SM ATE-B10, SM ATE- B11 or SMATE-K62. SMATE-B10 Baseband Generator with ARB and Digital Modulation SMATE-B13 (in baseband pat h A) SMAT ...

  • Vector SMATE200A - page 8

    Choose noise OPTIONAL Option Description Requires Not compatible with HW or SW Remarks SMATE-K62 Additive White Gaussian Noise ( AWGN ) SMATE-B13 - SW Step f Configure baseband path B OPTIONAL Choose baseband source MANDATORY Option Description Requires Not compatible with HW or SW Remarks SMATE-B13 Baseband Main Module SMATE-B13 (in baseband pat h ...

  • Vector SMATE200A - page 9

    Choose digital modulation systems with R&S WinIQSIM ™ 1 OPTIONAL Option Description Requires Not compatible with HW or SW Remarks SMATE-K11 Dig. Std. IS-95 SMATE -B 1 0 o r B11 - SW Wit h Wi n IQS I M ™ SMATE-K12 Dig. Std. CDMA20 00 SMATE-B10 or B11 - SW Wit h Wi n IQS I M ™ SMATE-K13 Dig. Std. 3GPP TD D SMATE-B10 or B11 - SW Wit h Wi n I ...

  • Vector SMATE200A - page 10

    Configuration Examples The modular design of the R&S SMATE200A allows the instrument to be equipped with up to two paths. This allo ws a multitud e of a pplications to be performed f or which several signal generato rs wer e previ ousl y re quired. One baseband generator and one RF path Instrument configuration Option Installed Description SMAT ...

  • Vector SMATE200A - page 11

    One baseband generator and two RF paths Instrument configuration Option Installed Description SMATE200A 1x Base unit SMATEB10x 1x Frequency option 1st RF path SMATEB20x 1x Frequency option 2n d RF path SMATE-B13 1x Baseband mai n module SMATE-B10 1x Baseband generat or Application example ¾ Generation of a modulated si gnal on path A and a CW inte ...

  • Vector SMATE200A - page 12

    Ordering information Vector Signal Generator 1 R&S SMATE200A 1400.7005.02 including power cable, Quick S tart Guide and CD-ROM (with operating and service manual) Options RF path A 100 kHz to 3 GHz R&S SMATEB103 1401.1000.02 100 kHz to 6 GHz R&S SMATEB106 1401.1200.02 Low Phase Noise and analog modulation FM / PhiM R&S SMATE-B22 140 ...

  • Vector SMATE200A - page 13

    Digital modulation systems using R&S WinIQSIM ™ 2 Digital Standard IS-95 (with R&S WinI QSIM ™ ) R&S SMATE-K11 1404.5907.02 Digital Standard CDMA2000 (with R&S WinIQSIM ™ ) R&S SMATE-K12 1404.6003.02 Digital Standard 3GPP TDD (with R&S WinIQSIM ™ ) R&S SMATE- K13 1404.6090.02 Digital Standard TD-SCDMA (with R& ...

  • Vector SMATE200A - page 14

    R&S ® is a regist ered trademark of Rohde & Schwa rz GmbH & Co. KG · Trad e names are tra demarks of the owners R&S ® SMAT E200A ⋅ Version 01.0 0 ⋅ April 2005 ⋅ Data without tolerance limits is not bind ing ⋅ Subject to change www.ro hd e-sc h wa r z. c o m Europe: Tel. +49 1805 12 4242 , e-mail: custome rsupport@rohde-sc ...

Produzent Vector Kategorie Portable Generator

Dokumente, die wir vom Produzenten des Geräts Vector SMATE200A erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Vector
- Bedienungsanleitungen SMATE200A
- Produktkarten Vector
- Informationsbroschüren
- oder Energieetiketten Vector SMATE200A
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Vector SMATE200A.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Vector SMATE200A, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Vector SMATE200A. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Vector SMATE200A ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Vector SMATE200A, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Vector SMATE200A hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Vector SMATE200A verständlich ist.

Eine gänzliche Bedienungsanleitung von Vector sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Vector SMATE200A bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Vector SMATE200A befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Vector SMATE200A, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Vector SMATE200A - die uns die ersten Schritte während der Nutzung von Vector SMATE200A erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Vector SMATE200A hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Vector SMATE200A im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Vector SMATE200A?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Vector SMATE200A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Vector SMATE200A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)