Bedienungsanleitung Lennox International Inc. 505

16 Seiten 0.3 mb
Download

Zur Seite of 16

Summary
  • Lennox International Inc. 505 - page 1

    02/06 505,021M *2P0206* *P505021M* E 2006 Lennox Industries Inc. Dallas, T exas, USA Humiditrol ® EDA Series Unit The Dave Lennox Signature t Collection Humiditrol ® En- hanced Dehumidification Accessory (EDA) is designed for installation with a Lennox R−410A split−system out door unit an d an air handler or a furnace with a variable speed bl ...

  • Lennox International Inc. 505 - page 2

    Page 2 EDA 01/06 W ARNING This cased product contains fiberglass wool. Dis- turbing the insulation during inst allation, mainte- nance, or rep air will expose you to fiberglass wool dust. Breathing this may cause lung cancer . (Fiber- glass wool is known to the St ate of California to cause cancer .) Fiberglass wool may also cause respiratory , ski ...

  • Lennox International Inc. 505 - page 3

    Page 3 EDA INST ALLA TION/ SERVICE INSTRUCTIONS Installation Dimensions and Arrangement Figure 1 AIR FLOW AIR FLOW UP-FLOW FURNACE UP-FLOW AIR HANDLER EDA−024B: 12−1/2 EDA−036C: 12−1/2 EDA−060D: 14 V aries by indoor coil model; see LENNOX Engineering Handbook. V aries by air handler model; see LENNOX Engineering Handbook for dimensions. 4 ...

  • Lennox International Inc. 505 - page 4

    Page 4 EDA 01/06 Component Functions Charge Compensator The charge compensator (shown i n figure 5) serves to maintain the proper amount of refrigerant circulating in larger systems. [Some systems do not require a charge compensator , but do require a simi- lar kit to connect into the system (see Engineering Hand- book)] The charge compensator s ...

  • Lennox International Inc. 505 - page 5

    Page 5 EDA INST ALLA TION/ SERVICE INSTRUCTIONS General Installation Information W ARNING Improper installation, adjustment, alteration, ser- vice or maintenance can cause personal injury , loss of life, or damage to property . Installation and service must be performed by a qualified installer or service agency . The EDA unit may be used in upflow ...

  • Lennox International Inc. 505 - page 6

    Page 6 EDA 01/06 Required Part s (all applications) EDA Unit, with check/flow restrictor & label Appropriate SignatureS t at t Thermostat 46M98 − Outdoor Sensor 84X49 − T wisted Pair Wire Appropriate Insulation and Piping Kit Required Part s (2−St age Heat Pump appl.) 12P61 − 75V A T ransformer (for HP applications) Installation Process ...

  • Lennox International Inc. 505 - page 7

    Page 7 EDA INST ALLA TION/ SERVICE INSTRUCTIONS INDOOR UNIT OUTDOOR UNIT air−flow V apor Line Liquid Line Liquid Line from Outdoor Unit Liquid Line to Indoor TXV TXV V apor Line Liquid Line MUST BE INSULA T ED MUST BE INSULA TED EDA CHARGE COMPENSA TOR 7/8 X 7/8 X 3/8 TEE UPFLOW POSITION Electrical Inlet T o Charge Compensator side connection (so ...

  • Lennox International Inc. 505 - page 8

    Page 8 EDA 01/06 Leak T esting, Evacuating, Charging IMPORT ANT The 3−way diverting valve actuator shaft set screw (see f i gure 7) is factory set and is not to be adjusted. 3−way Diverting V alve Operation NOTE − During system operation, the 3-way valve requires 24-volt power to drive between cooling and dehumidifica- tion. Th e 3−way dive ...

  • Lennox International Inc. 505 - page 9

    Page 9 EDA INST ALLA TION/ SERVICE INSTRUCTIONS Insulating and Sealing the Unit IMPORT ANT All piping, metering devices, and connections must be insulated to prevent moisture damage caused by sweating. Seal the unit so that warm air is not allowed into the cabi- net. This is especially import ant when the unit is inst alled in an unconditioned area ...

  • Lennox International Inc. 505 - page 10

    Page 10 EDA 01/06 EDA Unit Operation Th e EDA coil is added to an HV A C system downstream of th e indoor coil. In dehumidification mode, the coil becomes an extension of the condenser coil and injects heat into the indoor air stream. This dehumidification mode allows significantly improved control of the humidity in the conditioned space without o ...

  • Lennox International Inc. 505 - page 11

    Page 1 1 EDA INST ALLA TION/ SERVICE INSTRUCTIONS Cooling Mode (Dehumidification OFF) Figure 10 illustrates refrigerant flow in cooling mode (dehu- midification mode OFF), The liquid refrigerant from the outdoor unit enters the EDA module . Since there is no demand for dehumidification, the 3−way diverting valve assembly directs the flow back out ...

  • Lennox International Inc. 505 - page 12

    Page 12 EDA 01/06 Check List n Checkpoint What to Check Action Thermost at and Sensor Wiring Confirm Sensor connected to SignatureS tat t using twisted p air wire (see wiring diagram figure 13) Thermost at Humiditrol ® Installer Settings Confirm HUMIDITROL is enabled (see figure 8) Thermost at Humiditrol ® User Settings Confirm HUMIDITROL − Deh ...

  • Lennox International Inc. 505 - page 13

    Page 13 EDA INST ALLATION/ SERVICE INSTRUCTIONS Air Resist ance T able 2 shows air volume and tot al air resist ance for the available EDA models. T able 2 Air Resistance Air V olume T otal Air Resist ance Model No. cfm L/s in. w.g. Pa EDA−024B 400 190 0.05 12 600 285 0.10 25 800 380 0.15 37 1000 470 0.22 55 EDA−036C 600 285 0.05 12 800 380 0.0 ...

  • Lennox International Inc. 505 - page 14

    Page 14 EDA 01/06 Figure 12 T ypical EDA/Condensing Unit Wiring Diagram INDOOR UNIT B4 FA N Blue Y ellow Black K1 1st, cut yellow wire here. Use Wirenuts *OUTDOOR RELA Y  NOT REQUIRED WITH SINGLE- SPEED OUTDOOR FAN EDA Violet Orange OUTDOOR WIRING (VSM APPLICA TION ONL Y) Purple Black Black Purple VA LV E ACTUA TOR Y ellow Y ellow 2 2nd, rewire ...

  • Lennox International Inc. 505 - page 15

    Page 15 EDA INST ALLA TION/ SERVICE INSTRUCTIONS T ypical EDA/Heat Pump Wiring Diagram Figure 13 B4 FA N Blue Y ellow Black K1 1st, cu t yellow wire here. Use Wirenuts *OUTDOOR RELA Y  NOT REQUIRED WITH SINGLE- SPEED OUTDOOR FAN EDA Violet Orange Purple Black Black Purple VA LV E ACTUA TOR Y ellow Y ellow 2 2nd, rewire yellow wire as shown 7 5 1 ...

  • Lennox International Inc. 505 - page 16

    Page 16 EDA 01/06 Up flow/horizont al NOTE − AIR HANDLER REQUIRES FIELD−F ABRICA TED TRANSITION BETWEEN BLOWER OUTLET AND EDA COIL. [If furnace] Select indoor coil MUST BE TXV ONL Y Figure 14 Humiditrol ® Enhanced Dehumidification Accessory (EDA) Decision T ree Select EDA (REFER TO EDA ENGINEERING HANDBOOK) X = PREFERRED MA TCH−UP A = ALLOWE ...

Produzent Lennox International Inc. Kategorie Dehumidifier

Dokumente, die wir vom Produzenten des Geräts Lennox International Inc. 505 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lennox International Inc.
- Bedienungsanleitungen 505
- Produktkarten Lennox International Inc.
- Informationsbroschüren
- oder Energieetiketten Lennox International Inc. 505
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lennox International Inc. 505.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lennox International Inc. 505, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lennox International Inc. 505. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lennox International Inc. 505 ansehen.

Die komplette Bedienungsanleitung des Geräts Lennox International Inc. 505, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lennox International Inc. 505 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lennox International Inc. 505 verständlich ist.

Eine gänzliche Bedienungsanleitung von Lennox International Inc. sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lennox International Inc. 505 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lennox International Inc. 505 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lennox International Inc. 505, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lennox International Inc. 505 - die uns die ersten Schritte während der Nutzung von Lennox International Inc. 505 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lennox International Inc. 505 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lennox International Inc. 505 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lennox International Inc. 505?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lennox International Inc. 505 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lennox International Inc. 505 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)