Bedienungsanleitung Unigreen 20

20 Seiten 0.95 mb
Download

Zur Seite of 20

Summary
  • Unigreen 20 - page 1

    1 USE AND MAINTENANCE MANU AL UMP - MASTER serie MASTER 20/40/50/55 GB 05/2005 Read this manual carefully before use ...

  • Unigreen 20 - page 2

    2 ...

  • Unigreen 20 - page 3

    3 Sommario 1 USING AND KEEPING THE USE AND MAINTENANCE MANU AL .................... 4 1. 1 COMPOSITION OF THE MANU AL ....................................................................................... 4 1.2 GUARANTEE ....................................................................................................................... 4 1. 3 P ...

  • Unigreen 20 - page 4

    4 Thank you for having chosen UNIGREEN. The product you purchased has been designed and built with the greatest attention to the safety of the oper ator and the environment, ne vertheless there are still some residual risks due to the nature of the product used. For this reason we recommend reading all of this manual to avoid making mistakes in the ...

  • Unigreen 20 - page 5

    5 2 1 6 3 4 5 8 7 12 9 10 11 14 13 18 15 16 17 2 SAFETY REGULA TIONS AND RESIDU AL RISKS In relation to safety , the f ollowing ter ms will be used: Dangerous zones: any zone inside and/or near the machine where the presence of a person exposed constitutes a risk for the safety and health of the same person. P erson exposed: any person who has thei ...

  • Unigreen 20 - page 6

    6 Unigreen and in any case changing some of the parts descr ibed in the handbooks of the regulator , such as the manometer (stainless steel), the nozzles (large diameter ceramic) and eliminating the fine mesh filters to prevent blockages. 2. 2 PROHIBITED USE Using the machine with the following products is strictly forbidden: = P aints of any kind ...

  • Unigreen 20 - page 7

    7 FIG . 1 TYPE : ....................................................................... code: ........................................ N˚ ........................... massa a vuoto: ..........................Kg. max press. : ........... bar net mass massa totale ammessa: .............................. Kg. total mass via Rinaldi, 105 - Reggio Emili ...

  • Unigreen 20 - page 8

    8 3.3 ST AND ARDS OF REFERENCE: - MACHINES DIRECTIVE 98/37/CEE (Ex. Dir .89/392 CE). - Directive 86/188/CEE: risks deriving from exposure to noise (implemented in Italy by Legislativ e Decree D .L 277/1991) - DPR 547/1955: Regulations for the prevention of accidents and hygiene at work. - Legislative Decree D .Lgs . n°292 of the 4th of September 2 ...

  • Unigreen 20 - page 9

    9 4.3 PRELIMINAR Y CHECKS When you receiv e the machine, chec k that it is complete and no par ts are missing. If there are any damaged par ts, inf or m your local reseller or UNIGREEN directly in good time. When the machine is delivered, make sure you ask: a) that the machine is delivered with all of its parts fitted and that the fitting meets the ...

  • Unigreen 20 - page 10

    10 4.6 PUMP When using the pump scrupulously observe the instructions in the enclosed handbook supplied by the man ufacturer . The pump can be identified by the ratings plate on the same; the main data on the pressure and delivery are easy to find on this plate. Normally the pumps mustn’t exceed 550 RPM; a higher speed won’t improve performance ...

  • Unigreen 20 - page 11

    11 R5 auxiliary delivery union 4.8.2 GENERAL INSTRUCTIONS When using the pressure regulator , scr upulously obser ve the instructions in the enclosed handbook, below you will find generic indications for the major models fitted by Unigreen. All the regulation and adjustment tests must be carried out with c lean water . Pressure regulators without a ...

  • Unigreen 20 - page 12

    12 FIG . 6 4. 10 FILLING THE T ANK The machines for defensive crop treatments, in consideration of the safety of persons, animals and the protection of the environment, must only be filled indirectly from open water courses and only by free-falling water from the waterworks. The pipe used for filling must never come into contact with the liquid ins ...

  • Unigreen 20 - page 13

    13 C A B 4. 13 W ASHING THE SPRA YER Thoroughly wash the machine after each treatment pumping clean water through the circuit and clean the suction and delivery filters. Dir ty equipment is v er y dangerous for the people and environment. Discharging the residues of washing in the environment without taking precautions is forbidden as this pollutes ...

  • Unigreen 20 - page 14

    14 8 MAINTENANCE (to carry out with the internal combustion engine stopped or the plug detached for electric motors). The maintenance of the sprayer is essential for maintaining a high le vel of saf ety . Also consult the single handbooks of the main components of the spra yer . All of the maintenance operations and repairs must be carried out with ...

  • Unigreen 20 - page 15

    15 8.6 ST ORA GE IN A W AREHOUSE AND TRANSPOR T A TION The sprayer must be kept in a closed place away from excessive humidity and protected from frost. Especially if electrical pressure regulators, electrical motors, a spraying computer or similar components are fitted. Before storing the machine, after you have washed it, apply a light coat of oi ...

  • Unigreen 20 - page 16

    16 FIG . 9 UMP with MOTORPUMPE A : MUTORPUMPE B : SUCTION FIL TER C : EJECTOR D : FLOA TING FIL TER FIG. 9 CIRCUIT DIA GRAM ...

  • Unigreen 20 - page 17

    17 T ABLE OF DELIVER Y IN LITRES / MIN. OF THE CONICAL NOZZLES FOR "MITRA" SPRA Y GUN note: standard Ø2,5 nozzle NOZZLE DIAMETER Ø 1,0 Ø 1,2 Ø 1,5 Ø 1,8 Ø 2,0 Ø 2,3 Ø 2,5 Ø 3,0 PRESSURE (BAR) J E T CAP ACITY ( Lt / min ) 15 cone 2,45 3,60 4,60 5,90 6,90 8,10 9,20 1 1,5 direct jet 2,50 3,80 5,10 7,30 8,80 10,8 13,0 18,4 25 cone 3, ...

  • Unigreen 20 - page 18

    18 T ABLE 7 T ABLE OF PROGRAMMED MAINTENANCE OPERA TION 8 h 50 h 300 h END OF SEASON Check the level and state of the oil 0 Check the accumulator pressure 0 Check the suction (hoses, pipes, unions) 0 Check and clean the suction 0 and delivery filters Check the pump fixing feet 0 and screws in general Check the diaphragm and the oil X (1) X (2) and ...

  • Unigreen 20 - page 19

    19 T able of standard riggings supplied by UNIGREEN, special riggings must be agreed with the constructor . Multi-purpose Mobile Units with a higher capacity (800 - 1000 - 2000 litres) and cistern in organic glass or steel (galvanised or stainless) are available on request. For information apply to the administration office. T AB.10 ALLOWED FITTING ...

  • Unigreen 20 - page 20

    20 via Rinaldi, 105 - Loc. Cavazzoli (Reggio Emilia) - ITALY Tel. +39 0522 369811 Fax. +39 0522 369898 e-mail: info@unigreen-spa.com internet: www.unigreen-spa.com member of the group UNI 16100008F GB Maggio-05 Descriptions, indicativ e illustrations, UNIGREEN S .P .A. reser ves the right to make v ariations or modifications without pr ior wa rning ...

Produzent Unigreen Kategorie Spreader

Dokumente, die wir vom Produzenten des Geräts Unigreen 20 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Unigreen
- Bedienungsanleitungen 20
- Produktkarten Unigreen
- Informationsbroschüren
- oder Energieetiketten Unigreen 20
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Unigreen 20.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Unigreen 20, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Unigreen 20. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Unigreen 20 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Unigreen 20, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Unigreen 20 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Unigreen 20 verständlich ist.

Eine gänzliche Bedienungsanleitung von Unigreen sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Unigreen 20 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Unigreen 20 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Unigreen 20, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Unigreen 20 - die uns die ersten Schritte während der Nutzung von Unigreen 20 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Unigreen 20 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Unigreen 20 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Unigreen 20?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Unigreen 20 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Unigreen 20 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen