    1 USE AND MAINTENANCE MANU AL UMP - MASTER serie MASTER 20/40/50/55 GB 05/2005 Read this manual carefully before use ...

  • Unigreen 20 - page 2

    2 ...

  • Unigreen 20 - page 3

    3 Sommario 1 USING AND KEEPING THE USE AND MAINTENANCE MANU AL .................... 4 1. 1 COMPOSITION OF THE MANU AL ....................................................................................... 4 1.2 GUARANTEE ....................................................................................................................... 4 1. 3 P ...

  • Unigreen 20 - page 4

    4 Thank you for having chosen UNIGREEN. The product you purchased has been designed and built with the greatest attention to the safety of the oper ator and the environment, ne vertheless there are still some residual risks due to the nature of the product used. For this reason we recommend reading all of this manual to avoid making mistakes in the ...

  • Unigreen 20 - page 5

    5 2 1 6 3 4 5 8 7 12 9 10 11 14 13 18 15 16 17 2 SAFETY REGULA TIONS AND RESIDU AL RISKS In relation to safety , the f ollowing ter ms will be used: Dangerous zones: any zone inside and/or near the machine where the presence of a person exposed constitutes a risk for the safety and health of the same person. P erson exposed: any person who has thei ...

  • Unigreen 20 - page 6

    6 Unigreen and in any case changing some of the parts descr ibed in the handbooks of the regulator , such as the manometer (stainless steel), the nozzles (large diameter ceramic) and eliminating the fine mesh filters to prevent blockages. 2. 2 PROHIBITED USE Using the machine with the following products is strictly forbidden: = P aints of any kind ...

  • Unigreen 20 - page 7

    7 FIG . 1 TYPE : ....................................................................... code: ........................................ N˚ ........................... massa a vuoto: ..........................Kg. max press. : ........... bar net mass massa totale ammessa: .............................. Kg. total mass via Rinaldi, 105 - Reggio Emili ...

  • Unigreen 20 - page 8

    8 3.3 ST AND ARDS OF REFERENCE: - MACHINES DIRECTIVE 98/37/CEE (Ex. Dir .89/392 CE). - Directive 86/188/CEE: risks deriving from exposure to noise (implemented in Italy by Legislativ e Decree D .L 277/1991) - DPR 547/1955: Regulations for the prevention of accidents and hygiene at work. - Legislative Decree D .Lgs . n°292 of the 4th of September 2 ...

  • Unigreen 20 - page 9

    9 4.3 PRELIMINAR Y CHECKS When you receiv e the machine, chec k that it is complete and no par ts are missing. If there are any damaged par ts, inf or m your local reseller or UNIGREEN directly in good time. When the machine is delivered, make sure you ask: a) that the machine is delivered with all of its parts fitted and that the fitting meets the ...

  • Unigreen 20 - page 10

    10 4.6 PUMP When using the pump scrupulously observe the instructions in the enclosed handbook supplied by the man ufacturer . The pump can be identified by the ratings plate on the same; the main data on the pressure and delivery are easy to find on this plate. Normally the pumps mustn’t exceed 550 RPM; a higher speed won’t improve performance ...

  • Unigreen 20 - page 11

    11 R5 auxiliary delivery union 4.8.2 GENERAL INSTRUCTIONS When using the pressure regulator , scr upulously obser ve the instructions in the enclosed handbook, below you will find generic indications for the major models fitted by Unigreen. All the regulation and adjustment tests must be carried out with c lean water . Pressure regulators without a ...

  • Unigreen 20 - page 12

    12 FIG . 6 4. 10 FILLING THE T ANK The machines for defensive crop treatments, in consideration of the safety of persons, animals and the protection of the environment, must only be filled indirectly from open water courses and only by free-falling water from the waterworks. The pipe used for filling must never come into contact with the liquid ins ...

  • Unigreen 20 - page 13

    13 C A B 4. 13 W ASHING THE SPRA YER Thoroughly wash the machine after each treatment pumping clean water through the circuit and clean the suction and delivery filters. Dir ty equipment is v er y dangerous for the people and environment. Discharging the residues of washing in the environment without taking precautions is forbidden as this pollutes ...

  • Unigreen 20 - page 14

    14 8 MAINTENANCE (to carry out with the internal combustion engine stopped or the plug detached for electric motors). The maintenance of the sprayer is essential for maintaining a high le vel of saf ety . Also consult the single handbooks of the main components of the spra yer . All of the maintenance operations and repairs must be carried out with ...

  • Unigreen 20 - page 15

    15 8.6 ST ORA GE IN A W AREHOUSE AND TRANSPOR T A TION The sprayer must be kept in a closed place away from excessive humidity and protected from frost. Especially if electrical pressure regulators, electrical motors, a spraying computer or similar components are fitted. Before storing the machine, after you have washed it, apply a light coat of oi ...

  • Unigreen 20 - page 16

    16 FIG . 9 UMP with MOTORPUMPE A : MUTORPUMPE B : SUCTION FIL TER C : EJECTOR D : FLOA TING FIL TER FIG. 9 CIRCUIT DIA GRAM ...

  • Unigreen 20 - page 17

    17 T ABLE OF DELIVER Y IN LITRES / MIN. OF THE CONICAL NOZZLES FOR "MITRA" SPRA Y GUN note: standard Ø2,5 nozzle NOZZLE DIAMETER Ø 1,0 Ø 1,2 Ø 1,5 Ø 1,8 Ø 2,0 Ø 2,3 Ø 2,5 Ø 3,0 PRESSURE (BAR) J E T CAP ACITY ( Lt / min ) 15 cone 2,45 3,60 4,60 5,90 6,90 8,10 9,20 1 1,5 direct jet 2,50 3,80 5,10 7,30 8,80 10,8 13,0 18,4 25 cone 3, ...

  • Unigreen 20 - page 18

    18 T ABLE 7 T ABLE OF PROGRAMMED MAINTENANCE OPERA TION 8 h 50 h 300 h END OF SEASON Check the level and state of the oil 0 Check the accumulator pressure 0 Check the suction (hoses, pipes, unions) 0 Check and clean the suction 0 and delivery filters Check the pump fixing feet 0 and screws in general Check the diaphragm and the oil X (1) X (2) and ...

  • Unigreen 20 - page 19

    19 T able of standard riggings supplied by UNIGREEN, special riggings must be agreed with the constructor . Multi-purpose Mobile Units with a higher capacity (800 - 1000 - 2000 litres) and cistern in organic glass or steel (galvanised or stainless) are available on request. For information apply to the administration office. T AB.10 ALLOWED FITTING ...

  • Unigreen 20 - page 20

    20 via Rinaldi, 105 - Loc. Cavazzoli (Reggio Emilia) - ITALY Tel. +39 0522 369811 Fax. +39 0522 369898 e-mail: info@unigreen-spa.com internet: www.unigreen-spa.com member of the group UNI 16100008F GB Maggio-05 Descriptions, indicativ e illustrations, UNIGREEN S .P .A. reser ves the right to make v ariations or modifications without pr ior wa rning ...

メーカー Unigreen カテゴリー Spreader

Unigreen 20のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 20の取扱説明書
- Unigreenの製品カード
- パンフレット
- またはUnigreen 20の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Unigreen 20の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Unigreen 20の取り付け説明書、サービスマニュアル、簡易説明書、またはUnigreen 20のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Unigreen 20の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Unigreen 20デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがUnigreen 20を使用するのを助ける技術的文書のことです。説明書は通常、全てのUnigreen 20ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Unigreenの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Unigreen 20の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははUnigreen 20の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Unigreen 20に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Unigreen 20デバイスの基本機能を使うにあたってのヒント。 Unigreen 20のユーザーが使い始めるのを助けてくれるはずです。