    W a ter Sour ce Hea t Pump Systems SUBMITT AL DA T A Unit Designation Job Name Architect Engineer Contractor PERFORMANCE DA T A Cooling Capacity BTUH EER Heating Capacity BTUH COP Ambient Air o F Entering W ater T emp (Cooling) o F Entering Air T emp (Cooling) o F Entering W ater T emp (Heating) o F Entering Air T emp (Heating) o F Airow CFM ...

  • Heat Controller 60 HZR-410A - page 2

    ...

  • Heat Controller 60 HZR-410A - page 3

    Submittal Data HBH SerieS Heat Contr oller , Inc. 1 Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 1 Selection Procedure ................................................................................................................................................................ 2 HBH Series Nomenclature ............................. ...

  • Heat Controller 60 HZR-410A - page 4

    Heat Contr oller , Inc. HBH SerieS Submittal Data 2 Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 2 LW T = EW T - HE GPM x 500 LA T = EA T + HC CFM x1.08 LW T = EW T + HR GPM x 500 LA T (DB) = EA T (DB) - SC CFM x1.08 LC = TC - SC S/T = SC TC Heating Cooling To conver t Inch-Pound (English) to SI (Metric) Air Flow Correction T able 40 ...

  • Heat Controller 60 HZR-410A - page 5

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 3 Step 1 Determine the actual heating and cooling loads at the desired dry bulb and wet bulb conditions. Step 2 Obtain the follo wing design parameters: Entering wat er temperature , water ow r ate in GPM, air ow in CF M, water ow ...

  • Heat Controller 60 HZR-410A - page 6

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 4 Model Nomenclature Heat Controller OEM Price List HBH Large Com pact Hor izonta l Units Entering W ater Temperature Range: 20 - 120° F (-6. 7 - 48.9° C) Horiz ontal Si zes 072 - 120 HBH Large M odel Struc ture Basic Uni t Descript ion: ...

  • Heat Controller 60 HZR-410A - page 7

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 5 P er formance Data AHRI/ASHRAE/ISO 13256-1 ASHRAE/AHRI/ISO 13256-1. English (I-P) Units Model W ater Loop Heat P ump Ground W ater Heat P ump Ground Loop Hea t Pump Cooling 86°F Heating 68°F Cooling 59°F Heating 50°F Cooling 77°F Hea ...

  • Heat Controller 60 HZR-410A - page 8

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 6 F or operation in the shaded area when wat er is used in lieu of an anti-freeze solution, the L W T (Leaving Water T emperatur e) must be calculated. F low must be maintained to a lev el such that the L W T is maintained above 42°F [5.6? ...

  • Heat Controller 60 HZR-410A - page 9

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 7 P er formance Data: HBH072 Performance capacities shown in thousands of Btuh 2400 CFM Nominal Airow Heating & Cooling W A TER/BRINE Cooling - EA T 80/67°F Heating - EA T 70°F EWT °F FL OW gpm PD psi PD ft. TC SC kW HR EER HC kW ...

  • Heat Controller 60 HZR-410A - page 10

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 8 P er formance Data: HBH096 Performance capacities shown in thousands of Btuh 3200 CFM Nominal Airow Heating & Cooling W A TER/BRINE Cooling - EA T 80/67°F Heating - EA T 70°F EWT °F FL OW gpm PD psi PD ft. TC SC kW HR EER HC kW ...

  • Heat Controller 60 HZR-410A - page 11

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 9 P er formance Data: HBH120 Performance capacities shown in thousands of Btuh 4000 CFM Nominal Airow Heating & Cooling W A TER/BRINE Cooling - EA T 80/67°F Heating - EA T 70°F EWT °F FL OW gpm PD psi PD ft. TC SC kW HR EER HC kW ...

  • Heat Controller 60 HZR-410A - page 12

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 10 Air Flow C orrection T able Entering Air Correction T able HBH P er formance Data Correction T ables Per centage of Rated Airow Cooling Heating T otal Capacity Sensible Capacity Pow er Heat of Rejection Heating Capacity Pow er Heat of ...

  • Heat Controller 60 HZR-410A - page 13

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 11 Antifreez e Correction T able Antifreeze T ype Antifreeze % Cooling Heating WPD Corr . F ct. EW T 30°F EW T 90°F EW T 30°F T otal Cap Sens Cap Po we r Htg Cap Powe r Wat e r 0 1.000 1.000 1.000 Propylene Gly col 5 0.995 0.995 1.003 0. ...

  • Heat Controller 60 HZR-410A - page 14

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 12 Blower P er formance Data HBH072 - Standard Unit All Data is Wet Coil SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1800 BHP 0.28 0.32 0.35 0.39 0.42 0.45 0.48 0.52 0.56 0.60 0.64 0.69 0.72 0.76 ...

  • Heat Controller 60 HZR-410A - page 15

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 13 Blower P er formance Data HBH096 - Standard Unit All Data is Wet Coil SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 2400 BHP 0.45 0.50 0.54 0.59 0.63 0.69 0.74 0.80 0.85 0.90 0.94 0.99 1.04 1.10 ...

  • Heat Controller 60 HZR-410A - page 16

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 14 Blower P er formance Data HBH096 - Standard Unit SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 3300 BHP 1.01 1.08 1.14 1.21 1.28 1.33 1.39 1.45 1.51 1.58 1.64 1.72 1.78 1.84 1.93 2.00 Sheave/Mtr ...

  • Heat Controller 60 HZR-410A - page 17

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 15 Blower P er formance Data HBH120 - Standard Unit All Data is Wet Coil SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 3000 BHP 0.75 0.81 0.86 0.91 0.97 1.03 1.09 1.15 1.21 1.27 1.34 1.41 1.47 1.54 ...

  • Heat Controller 60 HZR-410A - page 18

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 16 Blower P er formance Data HBH120 - Standard Unit All Data is Wet Coil T able Continued from Pr evious Page SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 4300 BHP 2.00 2.07 2.16 2.23 2.31 2.41 2. ...

  • Heat Controller 60 HZR-410A - page 19

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 17 HBH Phy sical Data Model 072 096 120 Compressor Quantity Scroll Number of Circuits (C ompressors) 2 F actory Charge R-410a (oz) [kg] per circuit 60 [1.70] 76 [2.15] 80 [2.27] Blower Motor Blower Motor Quantity 1 Standard Motor (hp) [kw] ...

  • Heat Controller 60 HZR-410A - page 20

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 18 HBH072-120 Dimensional Data DIMENSIONAL DA T A T ABLE ON NEXT P AGE LEFT RETURN STRAIGHT DISCHARGE CAP CAP FRONT BSP A EAP CBP B A O P Q R K M F G E D BSP RIGHT RETURN STRAIGHT DISCHARGE 1 EAP 2 CAP CAP 2 FRONT CBP 1 5 4 LEGEND CAP=Compr ...

  • Heat Controller 60 HZR-410A - page 21

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 19 HBH072-120 Dimensional Data Model Overall Cabinet Discharge Connections Duct Flange Wat er Connections Electrical Knockouts Return Air Connections Using Return Air Opening A Depth B Width C Height D E Supply Depth F Supply Width G Supply ...

  • Heat Controller 60 HZR-410A - page 22

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 20 HBH Electrical Data Standard HB Model V oltage Code Rated V oltage V oltage Min Max Blower Option Compressor Fan Motor FLA T otal Unit FLA Min Circuit Amp Max F use/ HACR QT Y RLA LRA 072 H 208-3-60 197/254 A, B, C 2 10.4 73.0 4.0 24.8 2 ...

  • Heat Controller 60 HZR-410A - page 23

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 21 T ypical W iring Diagram Three P hase HBH072-120 With CXM C ontroller ...

  • Heat Controller 60 HZR-410A - page 24

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 22 Th is pro du c t s pe ci fic a tio n d oc ume nt is fur ni she d as a m ea ns to co py an d pa s te Cl ima te Ma s te r p rod uc t i n forma tio n i nto a proje c t spec i fic a tio n. It is n ot in ten d ed to be a co m pl e te lis t ...

  • Heat Controller 60 HZR-410A - page 25

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 23 HBH Series 60H z Engineering Specications Page 2 General: Furnish and install the HBH Series as indicated on the plans. Equipment shall be completely assembled, piped and internally wired. Capacities and characteristics as listed in t ...

  • Heat Controller 60 HZR-410A - page 26

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 24 HBH Series 60H z Engineering Specications Page 3 Fan and Motor Assembly: All units shall have belt-driven single centrifugal fan. Fan motor shall be permanently lubricated with thermal overload protection. Units supplied without perma ...

  • Heat Controller 60 HZR-410A - page 27

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 25 HBH Series 60H z Engineering Specications Page 4 Option: The unit shall be supplied with stainless steel drain pan. Electrical: A control box shall be located within the unit compressor compartment and shall contain a 75V A transforme ...

  • Heat Controller 60 HZR-410A - page 28

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 26 Hose Kit Assemblies: The following assemblies ship with the valves already assembled to the hose described: a. Supply and return hoses having ball valve with PT port. b. Supply hose having ball valve with PT port; return hose having auto ...

  • Heat Controller 60 HZR-410A - page 29

    ...

  • Heat Controller 60 HZR-410A - page 30

    06/2012 04/2009 1 1/2010 ...

Produzent Heat Controller Kategorie Heat Pump

Dokumente, die wir vom Produzenten des Geräts Heat Controller 60 HZR-410A erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Heat Controller
- Bedienungsanleitungen 60 HZR-410A
- Produktkarten Heat Controller
- Informationsbroschüren
- oder Energieetiketten Heat Controller 60 HZR-410A
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Heat Controller 60 HZR-410A.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Heat Controller 60 HZR-410A, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Heat Controller 60 HZR-410A. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Heat Controller 60 HZR-410A ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Heat Controller 60 HZR-410A, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Heat Controller 60 HZR-410A hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Heat Controller 60 HZR-410A verständlich ist.

Eine gänzliche Bedienungsanleitung von Heat Controller sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Heat Controller 60 HZR-410A bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Heat Controller 60 HZR-410A befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Heat Controller 60 HZR-410A, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Heat Controller 60 HZR-410A - die uns die ersten Schritte während der Nutzung von Heat Controller 60 HZR-410A erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Heat Controller 60 HZR-410A hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Heat Controller 60 HZR-410A im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Heat Controller 60 HZR-410A?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Heat Controller 60 HZR-410A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Heat Controller 60 HZR-410A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)