    W a ter Sour ce Hea t Pump Systems SUBMITT AL DA T A Unit Designation Job Name Architect Engineer Contractor PERFORMANCE DA T A Cooling Capacity BTUH EER Heating Capacity BTUH COP Ambient Air o F Entering W ater T emp (Cooling) o F Entering Air T emp (Cooling) o F Entering W ater T emp (Heating) o F Entering Air T emp (Heating) o F Airow CFM ...

  • Heat Controller 60 HZR-410A - page 2

    ...

  • Heat Controller 60 HZR-410A - page 3

    Submittal Data HBH SerieS Heat Contr oller , Inc. 1 Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 1 Selection Procedure ................................................................................................................................................................ 2 HBH Series Nomenclature ............................. ...

  • Heat Controller 60 HZR-410A - page 4

    Heat Contr oller , Inc. HBH SerieS Submittal Data 2 Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 2 LW T = EW T - HE GPM x 500 LA T = EA T + HC CFM x1.08 LW T = EW T + HR GPM x 500 LA T (DB) = EA T (DB) - SC CFM x1.08 LC = TC - SC S/T = SC TC Heating Cooling To conver t Inch-Pound (English) to SI (Metric) Air Flow Correction T able 40 ...

  • Heat Controller 60 HZR-410A - page 5

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 3 Step 1 Determine the actual heating and cooling loads at the desired dry bulb and wet bulb conditions. Step 2 Obtain the follo wing design parameters: Entering wat er temperature , water ow r ate in GPM, air ow in CF M, water ow ...

  • Heat Controller 60 HZR-410A - page 6

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 4 Model Nomenclature Heat Controller OEM Price List HBH Large Com pact Hor izonta l Units Entering W ater Temperature Range: 20 - 120° F (-6. 7 - 48.9° C) Horiz ontal Si zes 072 - 120 HBH Large M odel Struc ture Basic Uni t Descript ion: ...

  • Heat Controller 60 HZR-410A - page 7

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 5 P er formance Data AHRI/ASHRAE/ISO 13256-1 ASHRAE/AHRI/ISO 13256-1. English (I-P) Units Model W ater Loop Heat P ump Ground W ater Heat P ump Ground Loop Hea t Pump Cooling 86°F Heating 68°F Cooling 59°F Heating 50°F Cooling 77°F Hea ...

  • Heat Controller 60 HZR-410A - page 8

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 6 F or operation in the shaded area when wat er is used in lieu of an anti-freeze solution, the L W T (Leaving Water T emperatur e) must be calculated. F low must be maintained to a lev el such that the L W T is maintained above 42°F [5.6? ...

  • Heat Controller 60 HZR-410A - page 9

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 7 P er formance Data: HBH072 Performance capacities shown in thousands of Btuh 2400 CFM Nominal Airow Heating & Cooling W A TER/BRINE Cooling - EA T 80/67°F Heating - EA T 70°F EWT °F FL OW gpm PD psi PD ft. TC SC kW HR EER HC kW ...

  • Heat Controller 60 HZR-410A - page 10

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 8 P er formance Data: HBH096 Performance capacities shown in thousands of Btuh 3200 CFM Nominal Airow Heating & Cooling W A TER/BRINE Cooling - EA T 80/67°F Heating - EA T 70°F EWT °F FL OW gpm PD psi PD ft. TC SC kW HR EER HC kW ...

  • Heat Controller 60 HZR-410A - page 11

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 9 P er formance Data: HBH120 Performance capacities shown in thousands of Btuh 4000 CFM Nominal Airow Heating & Cooling W A TER/BRINE Cooling - EA T 80/67°F Heating - EA T 70°F EWT °F FL OW gpm PD psi PD ft. TC SC kW HR EER HC kW ...

  • Heat Controller 60 HZR-410A - page 12

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 10 Air Flow C orrection T able Entering Air Correction T able HBH P er formance Data Correction T ables Per centage of Rated Airow Cooling Heating T otal Capacity Sensible Capacity Pow er Heat of Rejection Heating Capacity Pow er Heat of ...

  • Heat Controller 60 HZR-410A - page 13

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 11 Antifreez e Correction T able Antifreeze T ype Antifreeze % Cooling Heating WPD Corr . F ct. EW T 30°F EW T 90°F EW T 30°F T otal Cap Sens Cap Po we r Htg Cap Powe r Wat e r 0 1.000 1.000 1.000 Propylene Gly col 5 0.995 0.995 1.003 0. ...

  • Heat Controller 60 HZR-410A - page 14

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 12 Blower P er formance Data HBH072 - Standard Unit All Data is Wet Coil SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1800 BHP 0.28 0.32 0.35 0.39 0.42 0.45 0.48 0.52 0.56 0.60 0.64 0.69 0.72 0.76 ...

  • Heat Controller 60 HZR-410A - page 15

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 13 Blower P er formance Data HBH096 - Standard Unit All Data is Wet Coil SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 2400 BHP 0.45 0.50 0.54 0.59 0.63 0.69 0.74 0.80 0.85 0.90 0.94 0.99 1.04 1.10 ...

  • Heat Controller 60 HZR-410A - page 16

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 14 Blower P er formance Data HBH096 - Standard Unit SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 3300 BHP 1.01 1.08 1.14 1.21 1.28 1.33 1.39 1.45 1.51 1.58 1.64 1.72 1.78 1.84 1.93 2.00 Sheave/Mtr ...

  • Heat Controller 60 HZR-410A - page 17

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 15 Blower P er formance Data HBH120 - Standard Unit All Data is Wet Coil SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 3000 BHP 0.75 0.81 0.86 0.91 0.97 1.03 1.09 1.15 1.21 1.27 1.34 1.41 1.47 1.54 ...

  • Heat Controller 60 HZR-410A - page 18

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 16 Blower P er formance Data HBH120 - Standard Unit All Data is Wet Coil T able Continued from Pr evious Page SCFM ESP 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 4300 BHP 2.00 2.07 2.16 2.23 2.31 2.41 2. ...

  • Heat Controller 60 HZR-410A - page 19

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 17 HBH Phy sical Data Model 072 096 120 Compressor Quantity Scroll Number of Circuits (C ompressors) 2 F actory Charge R-410a (oz) [kg] per circuit 60 [1.70] 76 [2.15] 80 [2.27] Blower Motor Blower Motor Quantity 1 Standard Motor (hp) [kw] ...

  • Heat Controller 60 HZR-410A - page 20

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 18 HBH072-120 Dimensional Data DIMENSIONAL DA T A T ABLE ON NEXT P AGE LEFT RETURN STRAIGHT DISCHARGE CAP CAP FRONT BSP A EAP CBP B A O P Q R K M F G E D BSP RIGHT RETURN STRAIGHT DISCHARGE 1 EAP 2 CAP CAP 2 FRONT CBP 1 5 4 LEGEND CAP=Compr ...

  • Heat Controller 60 HZR-410A - page 21

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 19 HBH072-120 Dimensional Data Model Overall Cabinet Discharge Connections Duct Flange Wat er Connections Electrical Knockouts Return Air Connections Using Return Air Opening A Depth B Width C Height D E Supply Depth F Supply Width G Supply ...

  • Heat Controller 60 HZR-410A - page 22

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 20 HBH Electrical Data Standard HB Model V oltage Code Rated V oltage V oltage Min Max Blower Option Compressor Fan Motor FLA T otal Unit FLA Min Circuit Amp Max F use/ HACR QT Y RLA LRA 072 H 208-3-60 197/254 A, B, C 2 10.4 73.0 4.0 24.8 2 ...

  • Heat Controller 60 HZR-410A - page 23

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 21 T ypical W iring Diagram Three P hase HBH072-120 With CXM C ontroller ...

  • Heat Controller 60 HZR-410A - page 24

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 22 Th is pro du c t s pe ci fic a tio n d oc ume nt is fur ni she d as a m ea ns to co py an d pa s te Cl ima te Ma s te r p rod uc t i n forma tio n i nto a proje c t spec i fic a tio n. It is n ot in ten d ed to be a co m pl e te lis t ...

  • Heat Controller 60 HZR-410A - page 25

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 23 HBH Series 60H z Engineering Specications Page 2 General: Furnish and install the HBH Series as indicated on the plans. Equipment shall be completely assembled, piped and internally wired. Capacities and characteristics as listed in t ...

  • Heat Controller 60 HZR-410A - page 26

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 24 HBH Series 60H z Engineering Specications Page 3 Fan and Motor Assembly: All units shall have belt-driven single centrifugal fan. Fan motor shall be permanently lubricated with thermal overload protection. Units supplied without perma ...

  • Heat Controller 60 HZR-410A - page 27

    Submittal Data HBH SerieS Heat Contr oller , Inc. Engineering Design Guide HBH SERIES Heat Contr oller , Inc. 25 HBH Series 60H z Engineering Specications Page 4 Option: The unit shall be supplied with stainless steel drain pan. Electrical: A control box shall be located within the unit compressor compartment and shall contain a 75V A transforme ...

  • Heat Controller 60 HZR-410A - page 28

    Heat Contr oller , Inc. HBH SerieS Submittal Data Heat Contr oller , Inc. HBH SERIES Engineering Design Guide 26 Hose Kit Assemblies: The following assemblies ship with the valves already assembled to the hose described: a. Supply and return hoses having ball valve with PT port. b. Supply hose having ball valve with PT port; return hose having auto ...

  • Heat Controller 60 HZR-410A - page 29

    ...

  • Heat Controller 60 HZR-410A - page 30

    06/2012 04/2009 1 1/2010 ...

メーカー Heat Controller カテゴリー Heat Pump

Heat Controller 60 HZR-410Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 60 HZR-410Aの取扱説明書
- Heat Controllerの製品カード
- パンフレット
- またはHeat Controller 60 HZR-410Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Heat Controller 60 HZR-410Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Heat Controller 60 HZR-410Aの取り付け説明書、サービスマニュアル、簡易説明書、またはHeat Controller 60 HZR-410Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Heat Controller 60 HZR-410Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Heat Controller 60 HZR-410Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHeat Controller 60 HZR-410Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのHeat Controller 60 HZR-410Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Heat Controllerの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Heat Controller 60 HZR-410Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHeat Controller 60 HZR-410Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Heat Controller 60 HZR-410Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Heat Controller 60 HZR-410Aデバイスの基本機能を使うにあたってのヒント。 Heat Controller 60 HZR-410Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Heat Controller 60 HZR-410Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHeat Controller 60 HZR-410Aのメーカー/サービスへの連絡先に関する情報。

Heat Controller 60 HZR-410Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHeat Controller 60 HZR-410Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHeat Controller 60 HZR-410Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)