    NOTE: Read the entire instruction in manual applicable to specific unit before starting the installation. This symbol → indicates a change since the last issue. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal ...

  • Bryant HUM-56-1 - page 2

    I. INSPECT PACKAGE AND CHECK EQUIPMENT Inspect contents of packaged humidifier. File claim with shipping company prior to installation if shipment is damaged or incom- plete. The package should contain: 1. Humidifier and media assembly 2. Humidistat 3. Template 4. Owner’s Manual 5. Warranty Certificate 6. Solenoid valve with bridge rectifier 7. S ...

  • Bryant HUM-56-1 - page 3

    VI. INSTALL DRAIN LINE 1. Use 1/2- or 5/8-in. vinyl tubing (field supplied) to connect drain on bottom of humidifier housing to an open drain. 2. Use supplied worm clamp to hold drain tubing in position over drain fitting outlet. CAUTION: Unit may leak if drain tubing is misapplied. Do not insert tubing inside of drain fitting outlet. 3. Make sure ...

  • Bryant HUM-56-1 - page 4

    II. SELECT LOCATION (SEE FIG. 5.) Humidifier must be installed on supply plenum only. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal. To access pad remove top or bottom cover to expose assembly (turn knob counter-clockwise). III. PR ...

  • Bryant HUM-56-1 - page 5

    INSTALLATION OF HUMBBSFP1016-A-- FAN POWERED HUMIDIFIER Bryant’s HUMBBSFP1016-A-- fan powered humidifier can only be installed on the supply plenum of a forced-air system. This unit requires an external 115-vac (fused) plug-in receptacle near the equipment for proper operation. It is recommended to install the humidifier where it can be easily se ...

  • Bryant HUM-56-1 - page 6

    IV. MOUNT THE HUMIDIFIER 1. Attach foam tape to back of mounting flange (exclude the off-set edge). 2. Hook off-set edge over opening cut in plenum. 3. Place humidifier in plenum aligning screw holes with flange. 4. Align, level, and tighten all screws for air tight seal. V. INSTALL DRAIN LINE 1. Use 5/8-in. vinyl tubing (field supplied) to connect ...

  • Bryant HUM-56-1 - page 7

    INSTALLATION OF HUMBBSBP2017-A-- BYPASS HUMIDIFIER Bryant’s HUMBBSBP2017-A-- bypass humidifier can be installed on either the supply or return plenum of a forced air system. This unit requires an external bypass duct between the supply- and return-air ductwork. It is recommended to install the humidifier where it can be easily serviced. If this h ...

  • Bryant HUM-56-1 - page 8

    5. Attach transfer tube to solenoid valve and insert free end into inlet fitting on top of unit housing. 6. Attach bridge rectifier to solenoid valve. 7. Insert sheet metal screws into lower holes in plenum, pre-drilled using template. 8. Tighten screws until heads protrude approximately 3/16-in. 9. Hang humidifier on bottom screws and push top of ...

  • Bryant HUM-56-1 - page 9

    II. SELECT LOCATION (SEE FIG. 14.) Humidifier may be installed on either supply or return plenum. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal. III. PREPARE PLENUM OPENING (SEE FIG. 2.) 1. Use template for marking humidifier openi ...

  • Bryant HUM-56-1 - page 10

    VIII. INSTALL HUMIDISTAT AND COMPLETE WIRING 1. Mount humidistat on inside wall or return-air duct in accordance with section INSTALLATION OF HUMIDIS- TAT on page 10. NOTE: Wiring must comply with national electrical code and any local codes or ordinances that may apply. (See Fig. 17.) IX. START-UP 1. Open saddle valve to permit water to flow to th ...

  • Bryant HUM-56-1 - page 11

    II. DUCT MOUNTING (LOW VOLTAGE) 1. Locate humidistat at least 8 in. upstream of humidifier in return-air duct. If mounting near elbow area, keep device 6 in. upstream of elbow so element will be affected by normal airflow. (See Fig. 20.) 2. Remove protective backing from template furnished with each control and apply self-adhesive side on return ai ...

  • Bryant HUM-56-1 - page 12

    V. OPERATION When relative humidity falls to humidistat set point, the humidistat switch makes contact and starts humidifier. In some central unit humidifier systems, furnace fan must be operating before humidi- fier will start. An increase in relative humidity above set point will stop humidifier. VI. CHECKOUT Place system in operation and observe ...

Produzent Bryant Kategorie Humidifier

Dokumente, die wir vom Produzenten des Geräts Bryant HUM-56-1 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Bryant
- Bedienungsanleitungen HUM-56-1
- Produktkarten Bryant
- Informationsbroschüren
- oder Energieetiketten Bryant HUM-56-1
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Bryant HUM-56-1.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Bryant HUM-56-1, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Bryant HUM-56-1. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Bryant HUM-56-1 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Bryant HUM-56-1, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Bryant HUM-56-1 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Bryant HUM-56-1 verständlich ist.

Eine gänzliche Bedienungsanleitung von Bryant sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Bryant HUM-56-1 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Bryant HUM-56-1 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Bryant HUM-56-1, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Bryant HUM-56-1 - die uns die ersten Schritte während der Nutzung von Bryant HUM-56-1 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Bryant HUM-56-1 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Bryant HUM-56-1 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Bryant HUM-56-1?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Bryant HUM-56-1 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Bryant HUM-56-1 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)