Bedienungsanleitung Heat Controller HMH30BS-1SINGLE-ZONE

23 Seiten 1.56 mb
Download

Zur Seite of 23

Summary
  • Heat Controller HMH30BS-1SINGLE-ZONE - page 1

    HMC30AS-1/HMH30AS-1, HMC30BS-1/HMH30BS-1Single-Zone ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 2

    INST ALLA TION OVER VIEW 2 The following should be always observed for safety .................... 3 Installation of indoor, outdoor unit ................................................ 4 Flaring work and connection of piping ........................................... 6 Connection of piping(Indoor) ...... 7 For left rear piping For right rear pip ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 3

    THE FOLLOWING SHOULD BE AL W A YS OBSER VED FOR SAFETY 3 ■ Be sure to read "THE FOLLOWING SHOULD BE ALWAYS OBSERVED FOR SAFETY" before installing the air conditioner. ■ Be sure to observe the cautions specified here as they include important items related to safety. ■ The indications and meanings are as follows. ■ After reading th ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 4

    4 INST ALLA TION OF INDOOR, OUTDOOR UNIT Read completely, then follow step by step. Select the best location Indoor unit ■ Do not have any heat or steam near the unit. ■ Select a place where there are no obstacles in front of the unit. ■ Make sure that condensation drainage can be conveniently routed away. ■ Do not install near a doorway. ? ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 5

    5 How to mount installation plate The wall you select should be strong and solid enough to prevent vibration Mount the installation plate on the wall with four type A screws. If mounting the unit on a concrete wall, use anchor bolts. ■ Mount the installation plate horizontally by aligning the centerline using a level. Measure the wall and mark th ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 6

    6 Connection of piping -Indoor FLARING WORK AND CONNECTION OF PIPING Flaring wor k Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure. Cut the pipes and the cable. ■ Use the piping kit accessory or the pipes purchased locally. ■ Measure the distance between the indoor and the o ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 7

    7 Main PCB Low panel Lower panel CAUTION When install, make sure that the remaining parts must be removed clearly so as not to damage the piping and drain hose, especially power cord and connecting cable. Route the indoor tubing and the drain hose in the direction of rear left. Insert the connecting cable into the indoor unit from the outdoor unit ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 8

    Wrap the insulation material around the connecting portion. ■ Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap. F Route the indoor tubing and the drain hose to the required piping hole position. A Insert the piping, drain hose and the connectin ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 9

    9 Insert the connecting cable into the indoor unit. ■ Don't connect the cable to the indoor unit. ■ Make a small loop with the cable for easy connection later. Tape the drain hose and the connecting cable. • Connecting cable C D Installation plate Three upper hooks Installation plate Indoor unit Three lower hooks Setting line Connecting ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 10

    10 Reroute the pipings and the drain hose across the back of the chassis. Reinstall the parts to the original position. ■ Refix the lower panel to the original position. ■ The chassis bottom(A) should be connected to the steel chassis(B) with green/yellow wiring using two screws. ■ Connect display conductor. ■ Refix the front right side pan ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 11

    11 ■ Unfold the tubing to downward slowly. ( ) ■ Bend the tubing to the left side of chassis. Installation Information (For left piping) • Good case For left piping. Follow the instruction below. ■ Press on the upper side of clamp. ( ) • Bad case ■ Following bending type from right to left could cause problem of pipe damage. CAUTION CAU ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 12

    12 Connection of piping -Outdoor Put a couple drops of refrigerant oil on the face of the flare before assembling taking care not to add any contaminants. Align the center of the pipings and sufficiently tighten the flare nut by hand. Connection of the drain hose ■ The drain hose can be connected at two different positions. Use the most convenien ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 13

    13 CAUTION Ø 8.5mm (0.33in) 20m m (0.79in) G N/YL AWG #12 20m m (0.79in) G N/YL AWG #20 The power supply cord connected to the outdoor unit should be complied with the following specifications (UL and CSA recognized one). The connecting cable connected to the indoor and outdoor unit should be complied with the following specifications (UL and CSA ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 14

    14 Connect the cab le to the outdoor unit Remove the control cover from the unit by loosening the screw. Connect the wires to the terminals on the control board individually. Secure the cable onto the control board with the cord clamp. Refix the control cover to the original position with the screw. Use a recognized circuit breaker 30A (30k) betwee ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 15

    15 CHECKING THE DRAINAGE AND FORMING THE PIPINGS Chec king the drainage Right side panel Lower panel To check the drainage. ■ Pour a glass of water on the drain pan. ■ Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit. D Drain piping ■ The drain hose should point downward for easy ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 16

    16 F orm the piping Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with two kinds of vinyl tapes. ■ If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately. In cases where the outdoor unit is in ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 17

    17 AIR PURGING Air purging Air and moisture remaining in the refrigerant system have undesirable effects as indicated below. ■ Pressure in the system rises. ■ Operating current rises. ■ Cooling(or heating) efficiency drops. ■ Moisture in the refrigerant circuit may freeze and block capillary tubing. ■ Water may lead to corrosion of parts ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 18

    18 Evacuation ■ Connect the charge hose end described in the preceding steps to the vacuum pump to evacuate the tubing and indoor unit. Confirm the "Lo" knob of the manifold valve is open. Then, run the vacuum pump. The operation time for evacuation varies with tubing length and capacity of the pump. The following table shows the time r ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 19

    19 ■ Each outdoor unit is factory charged (nameplate charge) for the evaporator as well as a 7.5m(25ft) line set. Any time a line set is used either shorter or longer then the nominal 7.5m(25ft) line set length the refrigerant charge has to adjusted. ■ Whether the line set is made shorter or longer you must adjust the charge based on how many f ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 20

    20 Outside ambient TEMP. The pressure of the gas side service valve 35 ° C(95 ° F) 4~5kg/cm 2 G(56.8~71.0 P.S.I.G.) TEST RUNNING Settlement of outdoor unit ■ Anchor the outdoor unit with a bolt and nut( ø 10mm(0.39in) tightly and horizontally on a concrete or rigid mount. ■ When installing on the wall, roof or rooftop, anchor the mounting ba ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 21

    MEMO 21 ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 22

    MEMO 22 ...

  • Heat Controller HMH30BS-1SINGLE-ZONE - page 23

    P/No. : 3829A20001V Specifications and performance data subject to change without notice. ...

Produzent Heat Controller Kategorie Heat Pump

Dokumente, die wir vom Produzenten des Geräts Heat Controller HMH30BS-1SINGLE-ZONE erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Heat Controller
- Bedienungsanleitungen HMH30BS-1SINGLE-ZONE
- Produktkarten Heat Controller
- Informationsbroschüren
- oder Energieetiketten Heat Controller HMH30BS-1SINGLE-ZONE
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Heat Controller HMH30BS-1SINGLE-ZONE.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Heat Controller HMH30BS-1SINGLE-ZONE, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Heat Controller HMH30BS-1SINGLE-ZONE. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Heat Controller HMH30BS-1SINGLE-ZONE ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Heat Controller HMH30BS-1SINGLE-ZONE, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Heat Controller HMH30BS-1SINGLE-ZONE hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Heat Controller HMH30BS-1SINGLE-ZONE verständlich ist.

Eine gänzliche Bedienungsanleitung von Heat Controller sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Heat Controller HMH30BS-1SINGLE-ZONE bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Heat Controller HMH30BS-1SINGLE-ZONE befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Heat Controller HMH30BS-1SINGLE-ZONE, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Heat Controller HMH30BS-1SINGLE-ZONE - die uns die ersten Schritte während der Nutzung von Heat Controller HMH30BS-1SINGLE-ZONE erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Heat Controller HMH30BS-1SINGLE-ZONE hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Heat Controller HMH30BS-1SINGLE-ZONE im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Heat Controller HMH30BS-1SINGLE-ZONE?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Heat Controller HMH30BS-1SINGLE-ZONE nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Heat Controller HMH30BS-1SINGLE-ZONE hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)