  • York YCW SERIES LD11554 - page 1

    LD1 1555 INST ALLA TION, OPERA TION, & MAINTENANCE F AN COIL AIR CONDITIONERS NEW RELEASE Form 1 15.20-NOM6 (1 106) ***** W ARNING TO INST ALLER, SERVICE PERSONNEL AND OWNER ***** Altering the product or replacing parts with non-authorize d factory parts voids all warranty or implied warranty and may result in adverse operational performance an ...

  • York YCW SERIES LD11554 - page 2

    JOHNSON CONTROLS 2 FORM 1 15.20-NOM6 (1 106) T ABLE OF CONTENTS FIG. 2 – PHYSICAL DIMENSIONS (INCHES) Reference Documents: • Parts List, Fan Coil Air Conditioners Form 1 15.20-RP2 (Latest) These documents can be ordered through Publications Dept. or downloaded @ http://intranet.york.com/web0003/ library/default.asp F D C B 2 1.75 A DRAIN KNOCKO ...

  • York YCW SERIES LD11554 - page 3

    3 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) INST ALLA TION RECEIVING Material in this shipment has been inspected at the factory and released to the transportation agency in good condition. When received, a visual inspect ion of all carton s shoul d be ma de imme diatel y . An y evid ence of rough handlin g or app arent damage should be note d on ...

  • York YCW SERIES LD11554 - page 4

    JOHNSON CONTROLS 4 FORM 1 15.20-NOM6 (1 106) INST ALLA TION 2 . Frame around the perimeter of the unit as required for securing the drywall. See T able 1 below for drywall openings. 3. Mo unt the un it in its perma nent locat ion, maki ng sure it is level to insure proper drainage and operation (two 1/2” holes have been provided on each end of th ...

  • York YCW SERIES LD11554 - page 5

    5 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) INST ALLA TION DUCTWORK Ductwork recommendations are as follows: • Insulate to prevent condensation during cooling. • Size to the unit openings are generally ac cept abl e bu t ar e de ter mine d by the eng ine erin g drawings. • Be sure units are ducted per local codes or national codes, as applic ...

  • York YCW SERIES LD11554 - page 6

    JOHNSON CONTROLS 6 FORM 1 15.20-NOM6 (1 106) T able 2 - ELECTRICAL DA T A UNIT MODEL KW TOT AL AMPS MIN. CIR. AMP ACITY MAX.OVERCURRENT PROTECTION 240V 208V 240V 208V 240V 208V 240V 208V 4CWE 0 0 0.0 1.1 N/A N/A N/A N/A N/A 1 1 0.8 5.3 4.7 7 6 15 15 2 2 1.5 9.4 8.3 12 1 1 15 15 3 3 2.3 13.6 1 1.9 17 15 20 15 4 4 3.0 17.8 15.5 23 20 25 20 6CWE 0 0 0 ...

  • York YCW SERIES LD11554 - page 7

    7 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) PIPING All piping connections are 5/8" OD copper tubing (see Fig.4). The supply and return piping must be adequately sized to meet the design water flow requirements as spec ified for the speci fic insta llatio n . Al l chille d water piping must be insulated to prevent condensation. It is also r ...

  • York YCW SERIES LD11554 - page 8

    JOHNSON CONTROLS 8 FORM 1 15.20-NOM6 (1 106) Drain Piping Con dens ate drai n lin es mu st be inst alle d wit h ade quat e slope away from the unit to assure positive drainage. Since the drain pan is located on the suction side of the blower , a negative pressure exists at the drain pan and a minimum trap of 1-1/2" must be provided in the drai ...

  • York YCW SERIES LD11554 - page 9

    9 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) SEQUENCE OF OPERA TION YCW With a Chilled W ater Coil The unit will respond to a cooling command from the thermostat by powering a water control valve open. The fan will operate at the speed selected at the thermostat. When the space reaches the temperature setpoint at the thermostat, the cooling valve w ...

  • York YCW SERIES LD11554 - page 10

    JOHNSON CONTROLS 10 FORM 1 15.20-NOM6 (1 106) MAINTENANCE MOTOR The blower motor should be cleaned annually and if it has oiling ports, it should be oiled with a good grade of SAE 20 oil. Normally a few drops of oil in each bearing is sufficient. COIL The coil must be kept clean by any of the following methods. 1. Cleaning with low-pressure compre ...

  • York YCW SERIES LD11554 - page 11

    1 1 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) This Page Intentionally Left Blank ...

  • York YCW SERIES LD11554 - page 12

    T ele. 800-861-1001 www .Y ork.com P .O. Box 1592, Y ork, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in USA T ele. 800-861-1001 P .O. Box 1592, Y ork, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in USA T ele. 800-861-1001 Copyright © by Johnson Controls 2006 ALL RIGHTS RESER VED www .Y ork.com C ...

Produzent York Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts York YCW SERIES LD11554 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen YCW SERIES LD11554
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York YCW SERIES LD11554
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York YCW SERIES LD11554.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York YCW SERIES LD11554, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York YCW SERIES LD11554. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York YCW SERIES LD11554 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York YCW SERIES LD11554, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York YCW SERIES LD11554 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York YCW SERIES LD11554 verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York YCW SERIES LD11554 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York YCW SERIES LD11554 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York YCW SERIES LD11554, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York YCW SERIES LD11554 - die uns die ersten Schritte während der Nutzung von York YCW SERIES LD11554 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York YCW SERIES LD11554 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York YCW SERIES LD11554 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York YCW SERIES LD11554?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York YCW SERIES LD11554 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York YCW SERIES LD11554 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)