    LD1 1555 INST ALLA TION, OPERA TION, & MAINTENANCE F AN COIL AIR CONDITIONERS NEW RELEASE Form 1 15.20-NOM6 (1 106) ***** W ARNING TO INST ALLER, SERVICE PERSONNEL AND OWNER ***** Altering the product or replacing parts with non-authorize d factory parts voids all warranty or implied warranty and may result in adverse operational performance an ...

  • York YCW SERIES LD11554 - page 2

    JOHNSON CONTROLS 2 FORM 1 15.20-NOM6 (1 106) T ABLE OF CONTENTS FIG. 2 – PHYSICAL DIMENSIONS (INCHES) Reference Documents: • Parts List, Fan Coil Air Conditioners Form 1 15.20-RP2 (Latest) These documents can be ordered through Publications Dept. or downloaded @ http://intranet.york.com/web0003/ library/default.asp F D C B 2 1.75 A DRAIN KNOCKO ...

  • York YCW SERIES LD11554 - page 3

    3 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) INST ALLA TION RECEIVING Material in this shipment has been inspected at the factory and released to the transportation agency in good condition. When received, a visual inspect ion of all carton s shoul d be ma de imme diatel y . An y evid ence of rough handlin g or app arent damage should be note d on ...

  • York YCW SERIES LD11554 - page 4

    JOHNSON CONTROLS 4 FORM 1 15.20-NOM6 (1 106) INST ALLA TION 2 . Frame around the perimeter of the unit as required for securing the drywall. See T able 1 below for drywall openings. 3. Mo unt the un it in its perma nent locat ion, maki ng sure it is level to insure proper drainage and operation (two 1/2” holes have been provided on each end of th ...

  • York YCW SERIES LD11554 - page 5

    5 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) INST ALLA TION DUCTWORK Ductwork recommendations are as follows: • Insulate to prevent condensation during cooling. • Size to the unit openings are generally ac cept abl e bu t ar e de ter mine d by the eng ine erin g drawings. • Be sure units are ducted per local codes or national codes, as applic ...

  • York YCW SERIES LD11554 - page 6

    JOHNSON CONTROLS 6 FORM 1 15.20-NOM6 (1 106) T able 2 - ELECTRICAL DA T A UNIT MODEL KW TOT AL AMPS MIN. CIR. AMP ACITY MAX.OVERCURRENT PROTECTION 240V 208V 240V 208V 240V 208V 240V 208V 4CWE 0 0 0.0 1.1 N/A N/A N/A N/A N/A 1 1 0.8 5.3 4.7 7 6 15 15 2 2 1.5 9.4 8.3 12 1 1 15 15 3 3 2.3 13.6 1 1.9 17 15 20 15 4 4 3.0 17.8 15.5 23 20 25 20 6CWE 0 0 0 ...

  • York YCW SERIES LD11554 - page 7

    7 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) PIPING All piping connections are 5/8" OD copper tubing (see Fig.4). The supply and return piping must be adequately sized to meet the design water flow requirements as spec ified for the speci fic insta llatio n . Al l chille d water piping must be insulated to prevent condensation. It is also r ...

  • York YCW SERIES LD11554 - page 8

    JOHNSON CONTROLS 8 FORM 1 15.20-NOM6 (1 106) Drain Piping Con dens ate drai n lin es mu st be inst alle d wit h ade quat e slope away from the unit to assure positive drainage. Since the drain pan is located on the suction side of the blower , a negative pressure exists at the drain pan and a minimum trap of 1-1/2" must be provided in the drai ...

  • York YCW SERIES LD11554 - page 9

    9 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) SEQUENCE OF OPERA TION YCW With a Chilled W ater Coil The unit will respond to a cooling command from the thermostat by powering a water control valve open. The fan will operate at the speed selected at the thermostat. When the space reaches the temperature setpoint at the thermostat, the cooling valve w ...

  • York YCW SERIES LD11554 - page 10

    JOHNSON CONTROLS 10 FORM 1 15.20-NOM6 (1 106) MAINTENANCE MOTOR The blower motor should be cleaned annually and if it has oiling ports, it should be oiled with a good grade of SAE 20 oil. Normally a few drops of oil in each bearing is sufficient. COIL The coil must be kept clean by any of the following methods. 1. Cleaning with low-pressure compre ...

  • York YCW SERIES LD11554 - page 11

    1 1 JOHNSON CONTROLS FORM 1 15.20-NOM6 (1 106) This Page Intentionally Left Blank ...

  • York YCW SERIES LD11554 - page 12

    T ele. 800-861-1001 www .Y ork.com P .O. Box 1592, Y ork, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in USA T ele. 800-861-1001 P .O. Box 1592, Y ork, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in USA T ele. 800-861-1001 Copyright © by Johnson Controls 2006 ALL RIGHTS RESER VED www .Y ork.com C ...

Производитель York Категория Air Conditioner

Документы, которые мы получаем от производителя устройства York YCW SERIES LD11554 мы можем разделить на несколько групп. Это в частности:
- технические чертежи York
- инструкции обслуживания YCW SERIES LD11554
- паспорта изделия York
- информационные брошюры
- энергетические этикетки York YCW SERIES LD11554
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания York YCW SERIES LD11554.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа York YCW SERIES LD11554, инструкции обслуживания, короткие инструкции или инструкции пользователя York YCW SERIES LD11554. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия York YCW SERIES LD11554.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства York YCW SERIES LD11554, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании York YCW SERIES LD11554 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей York YCW SERIES LD11554.

Полная инструкция обслуживания York, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией York YCW SERIES LD11554 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания York YCW SERIES LD11554, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся York YCW SERIES LD11554, которое найдем в данном документе
3. Советы по использованию основных функций устройства York YCW SERIES LD11554 - которые должны облегчить нам первые шаги во время использования York YCW SERIES LD11554
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем York YCW SERIES LD11554
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра York YCW SERIES LD11554 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся York YCW SERIES LD11554?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с York YCW SERIES LD11554, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с York YCW SERIES LD11554 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)