Bedienungsanleitung Heat Controller R-410A

16 Seiten 1.97 mb
Download

Zur Seite of 16

Summary
  • Heat Controller R-410A - page 1

    OUTDOOR SPLIT SYSTEM HEA T PUMP INST ALLA TION INSTR UCTIONS DO NO T DESTRO Y . PLEASE READ CAREFULL Y AND KEEP IN A SAFE PLA CE FOR FUTURE REFERENCE. IMPOR T ANT A TTENTION INST ALLERS: It is your responsibility to kno w this product better than y our customer . This includes being able to install the pr oduct according to strict saf ety guideline ...

  • Heat Controller R-410A - page 2

    2 W ARNING: ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage. Improper servicing could result in dangerous operation, serious injur y , death or property damage. • Before servicing, disconnect all electrical power to the indoor blo wer . • ...

  • Heat Controller R-410A - page 3

    3 HEA T PUMP INST ALLA TION General Information Split system heat pumps are designed only f or outdoor rooftop or ground le v el installations. This unit has been tested f or capacity and efficiency in accordance with AHRI Standards and will provide man y years of saf e and dependable comf or t, providing it is properly installed and maintained. A ...

  • Heat Controller R-410A - page 4

    4 Connecting RefrigerantT ubing Between  the Indoor & Outdoor Unit CA UTION: When servicing, cover or seal openings to minimize the exposure of the refrigerant system to air to prevent accum ulation of moisture and other contaminants. After outdoor and indoor unit placement has been determined, route refr igerant tubing between the ...

  • Heat Controller R-410A - page 5

    5 the line-v oltage leads to the ter minals on the contactor inside the control compar tment. • Use only copper wire for the line voltage power supply to this unit as listed in T able 1. Use proper code agency listed conduit and a conduit connector f or connecting the supply wires to the unit. Use of rain tight co ...

  • Heat Controller R-410A - page 6

    6 • Do not add additional oil to motors unequipped with oil tubes. The compressor is her metically sealed at the f actor y and does not require lubrication. ST ART UP & ADJUSTMENTS Pre-Start Check List √ V er ify the unit is le vel and has sufficient clearances f or unobstructed airflow . √ V erify the o ...

  • Heat Controller R-410A - page 7

    7 ther mostat. NO TE: The blo wer should also stop unless f an s witch is set to the ON position. System Heating (Optional) 1. If heating equipment (fur nace, air handler) is pro vided with the system, lower the thermostat setpoint temperature to the lo west temperature setting and change the ther mostat’ s system mode to HEA T . 2 . Gradually in ...

  • Heat Controller R-410A - page 8

    8 • A high-pressure s witch is f actor y installed and located inter nally on the compressor discharge line of the outdoor unit. If the discharge pressure rises above 650 psig, theswitchwillopenand de-energizetheoutdoorunit.  The s witch will close again after the discharge pressure decreases to 460 psig. NO TE: When ...

  • Heat Controller R-410A - page 9

    9 2 . Measure the liquid refrigerant temperature (in F ahrenheit) at the ser vice valv e. 3. Deter mine the required liquid refrigerant pressure . Ref er to T ables 3-9 (pages 11-13) and Figures 5-11 (pages 13-16). • If the pressure measured in Step 1 is greater than the required liquid refrigerant pressure deter ...

  • Heat Controller R-410A - page 10

    10 Figure 4. Charging Chart for 3 T on Units Liquid T emperature (° F) Liquid Pressure (psig) 250 275 300 325 350 375 400 425 450 475 500 70 75 80 85 90 95 100 10 51 10 115 120 12 5 Remo ve refr igerant when abo ve cur ve Add refrigerant when below cur ve Figure 5. Charging Chart for 4 T on Units Liquid T emperature (° F) Liquid Pressure (psig) 2 ...

  • Heat Controller R-410A - page 11

    11 Figure 6. Charging Chart for 5 T on Units Liquid T emperature (° F) Liquid Pressure (psig) 250 275 300 325 350 375 400 425 450 475 500 70 75 80 85 90 95 100 105 110 11 51 20 125 Remo ve refr igerant when abo ve cur ve Add refrigerant when below cur ve Figure 7. Heating Charging Chart Liquid T emperature (° F) Liquid Pressure (psig) 20 0 22 5 2 ...

  • Heat Controller R-410A - page 12

    12 HPS W2 OU T LP S Y OU T Y2 OU T Y2 W2 IN L COI L C Y O R AMB DF 1D F2 RV OUTDOOR FA N MO TO R T1 T2 L1 L2 RIGHT COMPRESSOR HPS LPS RV COIL C R S CCH BLACK YELLOW RED C H C TO THERMOST AT AMB SENSOR OD SENSOR CAP ACIT OR CONT AC TO R LEFT DEFROST BOARD C GRN DL 1L 2 SINGLE PHASE FIELD SUPPL Y GROUNDING SCREW F BLACK ORANGE S R BLUE C S R H C F 20 ...

  • Heat Controller R-410A - page 13

    13 AMB HP S W2 OU T LP S Y OU T Y2 OU T Y2 W2 IN L COIL C Y O R DF1 DF2 RV BLACK RED OUTDOOR F AN MO TO R T1 T2 L1 L2 COMPRESSOR HPS LPS RV COIL CCH BLACK RED BLUE ORANGE H F C R S TO THERMOST AT AMB SENSOR OD SENSOR CONT AC TO R DEFROST BOARD LFT RT S L H C NC NO COM GRND GROUNDING SCREW FA N RELA Y CA PA CITOR L1 L2 YELLOW C TERMINAL BLOCK D RED ...

  • Heat Controller R-410A - page 14

    14 HPS W2 OU T LP S Y OUT Y2 OUT Y2 W2 IN L COIL C Y O R AMB DF 1D F2 RV OUTDOOR F AN MO TO R COMPRESSOR HPS LPS RV COIL CCH WHITE YELLOW H C TO THERMOST AT AMB SENSOR OD SENSOR BR OW N BLACK CONT AC TO R T1 T2 L1 L2 LEFT RIGHT Y1 C Y2 ECM L2 L1 DEFROST BOARD RED BLACK YELLOW GRND GROUNDING SCREW L1 L2 C R S BLUE C TERMINAL BLOCK D 6 BLUE BLACK YEL ...

  • Heat Controller R-410A - page 15

    15 ...

  • Heat Controller R-410A - page 16

    INST ALLA TION / PERFORMANCE CHECK LIST REFRIGERA TION SYSTEM W as unit given 24 hr w arm up per iod for cr ankcase heaters? YES NO Stage-1 Liquid Pressure (high side) ________________________ Stage-1 Suction Pressure (low side) ________________________ ELECTRICAL SYSTEM Electrical connections tight? YES NO Line voltage polarity correct? YES NO Rat ...

Produzent Heat Controller Kategorie Heat Pump

Dokumente, die wir vom Produzenten des Geräts Heat Controller R-410A erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Heat Controller
- Bedienungsanleitungen R-410A
- Produktkarten Heat Controller
- Informationsbroschüren
- oder Energieetiketten Heat Controller R-410A
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Heat Controller R-410A.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Heat Controller R-410A, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Heat Controller R-410A. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Heat Controller R-410A ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Heat Controller R-410A, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Heat Controller R-410A hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Heat Controller R-410A verständlich ist.

Eine gänzliche Bedienungsanleitung von Heat Controller sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Heat Controller R-410A bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Heat Controller R-410A befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Heat Controller R-410A, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Heat Controller R-410A - die uns die ersten Schritte während der Nutzung von Heat Controller R-410A erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Heat Controller R-410A hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Heat Controller R-410A im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Heat Controller R-410A?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Heat Controller R-410A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Heat Controller R-410A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)