Bedienungsanleitung Heatcraft Refrigeration Products 2500018

16 Seiten 1.09 mb
Download

Zur Seite of 16

Summary
  • Heatcraft Refrigeration Products 2500018 - page 1

    Installation and Opera tions Manual Remote A ir- C ooled C ondenser Bulletin H-IM-RAC C August 2007 P ar t Number 2500018 Replaces H-IM-73A and H-IM-43B T able of C onten ts Inspection ������������������������������������������������������� ...

  • Heatcraft Refrigeration Products 2500018 - page 2

    Inspec tion Shipmen t s hould be checked again st t he b ill of l ading to verif y that all items listed have been received. All parts should be carefully inspec ted to determine if any damage was incurred in shipment. An y sho rtage an d/o r clai ms f or da mage s hou ld be i mmed iat ely reported to the deliv ering carrier , follow ed b y ling ...

  • Heatcraft Refrigeration Products 2500018 - page 3

    The condenser should be locat ed n o clos er th an f our feet from any wall or other obstruction to provide sucient clearance for air entrance . Do not attach ductwork to the coil inlet or fan ou tle t. Ca re sho uld be tak en to av oid ai r rec irc ul ati on co ndi tio ns that can be caused by sight screening , walls , etc . Keep unit fan disch ...

  • Heatcraft Refrigeration Products 2500018 - page 4

    V er tical Condenser V ertica l airow unit s shou ld be loca ted no clos er tha n the widt h of the unit f rom a w all or othe r obstr uction . If two or more u nits are to be po sitioned in th e sa me area, a similar distance sho uld be maintained between adjacent units. Sufficient free area should be left around and below unit to avoid air res ...

  • Heatcraft Refrigeration Products 2500018 - page 5

    Leg Assembly for Horiz ontal Airow Installation (Models 024-133; 5-26) Remove bolts securing condenser to skid. Remove item 1 and attach to rear of bottom leg (item A) to complete mounting base. I tem 2 is not required in the horizontal discharge application and ma y be discarded. Condenser can be hoisted by the 1-1/ 2” holes in leg assemblies ...

  • Heatcraft Refrigeration Products 2500018 - page 6

    Elec trical W iring The electrical installation should be in accordanc e with National Elec trical Code, local codes and regulations . Proper over current pr otection should be pr ovided f or the fan mot ors. Wiring diagrams shown are only basic and do not show fuses, disconnec t switches, etc., which must be pro vided in the eld. All s tand ard ...

  • Heatcraft Refrigeration Products 2500018 - page 7

    Diagram 3. T ypical Wiring Diagram for 208-230/1/60 with F an Cycling. Diagram 5. T ypical Wiring Diagram for 208-230-460/3/60 with F an Cycling Diagram 4. T ypical Wiring Diagram for 208-230-460/3/60 Diagram 1. T ypical Wiring Diagram for Models 1-3. C ONTROL CIRCUIT : May be 24 volt , 120 volt, or 230 v olt (as specied)� Diagram 2. T ypical ...

  • Heatcraft Refrigeration Products 2500018 - page 8

    Start Up Check for proper fan rota tion. Air is dra wn through the c oil on all u nits . Be s ure t he fans turn free ly . R otat ion of the moto rs and blades should be in a clockwise direction looking at the unit from the blade side. On three-phase units, it m ay be neces sar y to rev erse two of the three power leads to the unit . NO TE: The man ...

  • Heatcraft Refrigeration Products 2500018 - page 9

    of the fans ar e constant speed and ar e cycled separa tely using ambient sensing thermostats. Flooded Head P ressure C ontrol V alve (FHP) The FHP system of head pressure control is a completely automatic contr ol that maintains a pr eset condenser pressure without need of seasonal adjustment. T he contr ol maintains head pressur e by backing liqu ...

  • Heatcraft Refrigeration Products 2500018 - page 10

    10 Part # 2500018 Installation and Operations Manual Model Standard R-22 Charge Additional Lbs. R-22 Char ge for FHP at 20° T .D. °F Minimum Ambient at Condenser* WSS DV T FCB +50°F +40°F +20°F 0°F -20°F 008 001 1 1.0 1.0 1.0 1.0 1.0 1.0 009 — 1.5 1.0 2.0 2.0 2.0 2.0 2.0 010 002 2 1.5 2.0 2.5 2.5 2.5 3.0 016 003 3 3.5 4.0 4.5 4.5 5.0 5.0 0 ...

  • Heatcraft Refrigeration Products 2500018 - page 11

    Sy stem W arranty This equipment is designed to operate properly and produce rated capacit y when installed in accordance with accepted industr y standards . F ailure to meet the following conditions ma y result in voiding of the system warranty: System piping must be installed following industr y standards for good piping pr actices. Iner t gas mu ...

  • Heatcraft Refrigeration Products 2500018 - page 12

    T able 9� Specications 1 Motor voltage 208-230/1/60; 1075 RPM 2 Motor voltage 208-230-460/3/60; 1140 RPM NOTE: Model 008-010, 1-2; av ailable in 115/1/60 voltage; model 024-133, 5-26 available in 575/3/60 voltage 12 Part # 2500018 Installation and Operations Manual 18” 22” 13/32” x 1/2” Slots Unit l egs ar e remo vab le fr om un its in ...

  • Heatcraft Refrigeration Products 2500018 - page 13

    Remote Air-Cooled Condenser Installation and Operations Manual, A ugust 2007 13 Remote Air-Cooled C ondenser Electrical junction box is loc ated on header end of units unless optional F AN CYCLING is ordered on 230 and 460 volt. In which c ase, three phase units electrical box is loc ated on unit end opposite header end. 43” 24 1/2” 16” 21 1/ ...

  • Heatcraft Refrigeration Products 2500018 - page 14

    Commercial Refrigeration P ar ts 14 Part # 2500018 Installation and Operations Manual Model Motors F an Blades F an Guards WSS DV T FCB Quantity 230/1/60 230/460/3/60 008 001 1 1 2537974 — 2291820 2318491 009 — 1.5 1 2537974 — 2291820 2318491 010 002 2 1 2537974 — 2291820 2318491 016 003 3 1 2537974 — 2291836 2318491 024 005 5 1 2530355 2 ...

  • Heatcraft Refrigeration Products 2500018 - page 15

    Remote Air-Cooled Condenser Installation and Operations Manual, A ugust 2007 15 Remote Air-Cooled C ondenser Installation Checklist Condenser Star t Up Date Model Number Serial Number Electr ical V oltage Amperage Installer : Name & Addr ess Please retain this inf or mation with the condenser . ...

  • Heatcraft Refrigeration Products 2500018 - page 16

    Since product improv ement is a continuing eort, we reserve the right to make changes in specications without notice. Heatcr af t Refriger ation Products LL C • 2175 West P ark Place Blvd., Stone Mountain, GA 30087 P: 770.465.5600 • F: 770.465.5990 • www .heatcraftrpd.com C L I M A T E C O N T R O L Commercial Refrigeration Parts The na ...

Produzent Heatcraft Refrigeration Products Kategorie Clothes Dryer

Dokumente, die wir vom Produzenten des Geräts Heatcraft Refrigeration Products 2500018 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Heatcraft Refrigeration Products
- Bedienungsanleitungen 2500018
- Produktkarten Heatcraft Refrigeration Products
- Informationsbroschüren
- oder Energieetiketten Heatcraft Refrigeration Products 2500018
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Heatcraft Refrigeration Products 2500018.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Heatcraft Refrigeration Products 2500018, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Heatcraft Refrigeration Products 2500018. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Heatcraft Refrigeration Products 2500018 ansehen.

Die komplette Bedienungsanleitung des Geräts Heatcraft Refrigeration Products 2500018, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Heatcraft Refrigeration Products 2500018 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Heatcraft Refrigeration Products 2500018 verständlich ist.

Eine gänzliche Bedienungsanleitung von Heatcraft Refrigeration Products sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Heatcraft Refrigeration Products 2500018 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Heatcraft Refrigeration Products 2500018 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Heatcraft Refrigeration Products 2500018, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Heatcraft Refrigeration Products 2500018 - die uns die ersten Schritte während der Nutzung von Heatcraft Refrigeration Products 2500018 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Heatcraft Refrigeration Products 2500018 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Heatcraft Refrigeration Products 2500018 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Heatcraft Refrigeration Products 2500018?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Heatcraft Refrigeration Products 2500018 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Heatcraft Refrigeration Products 2500018 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)