  • Heatcraft Refrigeration Products 2500018 - page 1

    Installation and Opera tions Manual Remote A ir- C ooled C ondenser Bulletin H-IM-RAC C August 2007 P ar t Number 2500018 Replaces H-IM-73A and H-IM-43B T able of C onten ts Inspection ������������������������������������������������������� ...

  • Heatcraft Refrigeration Products 2500018 - page 2

    Inspec tion Shipmen t s hould be checked again st t he b ill of l ading to verif y that all items listed have been received. All parts should be carefully inspec ted to determine if any damage was incurred in shipment. An y sho rtage an d/o r clai ms f or da mage s hou ld be i mmed iat ely reported to the deliv ering carrier , follow ed b y ling ...

  • Heatcraft Refrigeration Products 2500018 - page 3

    The condenser should be locat ed n o clos er th an f our feet from any wall or other obstruction to provide sucient clearance for air entrance . Do not attach ductwork to the coil inlet or fan ou tle t. Ca re sho uld be tak en to av oid ai r rec irc ul ati on co ndi tio ns that can be caused by sight screening , walls , etc . Keep unit fan disch ...

  • Heatcraft Refrigeration Products 2500018 - page 4

    V er tical Condenser V ertica l airow unit s shou ld be loca ted no clos er tha n the widt h of the unit f rom a w all or othe r obstr uction . If two or more u nits are to be po sitioned in th e sa me area, a similar distance sho uld be maintained between adjacent units. Sufficient free area should be left around and below unit to avoid air res ...

  • Heatcraft Refrigeration Products 2500018 - page 5

    Leg Assembly for Horiz ontal Airow Installation (Models 024-133; 5-26) Remove bolts securing condenser to skid. Remove item 1 and attach to rear of bottom leg (item A) to complete mounting base. I tem 2 is not required in the horizontal discharge application and ma y be discarded. Condenser can be hoisted by the 1-1/ 2” holes in leg assemblies ...

  • Heatcraft Refrigeration Products 2500018 - page 6

    Elec trical W iring The electrical installation should be in accordanc e with National Elec trical Code, local codes and regulations . Proper over current pr otection should be pr ovided f or the fan mot ors. Wiring diagrams shown are only basic and do not show fuses, disconnec t switches, etc., which must be pro vided in the eld. All s tand ard ...

  • Heatcraft Refrigeration Products 2500018 - page 7

    Diagram 3. T ypical Wiring Diagram for 208-230/1/60 with F an Cycling. Diagram 5. T ypical Wiring Diagram for 208-230-460/3/60 with F an Cycling Diagram 4. T ypical Wiring Diagram for 208-230-460/3/60 Diagram 1. T ypical Wiring Diagram for Models 1-3. C ONTROL CIRCUIT : May be 24 volt , 120 volt, or 230 v olt (as specied)� Diagram 2. T ypical ...

  • Heatcraft Refrigeration Products 2500018 - page 8

    Start Up Check for proper fan rota tion. Air is dra wn through the c oil on all u nits . Be s ure t he fans turn free ly . R otat ion of the moto rs and blades should be in a clockwise direction looking at the unit from the blade side. On three-phase units, it m ay be neces sar y to rev erse two of the three power leads to the unit . NO TE: The man ...

  • Heatcraft Refrigeration Products 2500018 - page 9

    of the fans ar e constant speed and ar e cycled separa tely using ambient sensing thermostats. Flooded Head P ressure C ontrol V alve (FHP) The FHP system of head pressure control is a completely automatic contr ol that maintains a pr eset condenser pressure without need of seasonal adjustment. T he contr ol maintains head pressur e by backing liqu ...

  • Heatcraft Refrigeration Products 2500018 - page 10

    10 Part # 2500018 Installation and Operations Manual Model Standard R-22 Charge Additional Lbs. R-22 Char ge for FHP at 20° T .D. °F Minimum Ambient at Condenser* WSS DV T FCB +50°F +40°F +20°F 0°F -20°F 008 001 1 1.0 1.0 1.0 1.0 1.0 1.0 009 — 1.5 1.0 2.0 2.0 2.0 2.0 2.0 010 002 2 1.5 2.0 2.5 2.5 2.5 3.0 016 003 3 3.5 4.0 4.5 4.5 5.0 5.0 0 ...

  • Heatcraft Refrigeration Products 2500018 - page 11

    Sy stem W arranty This equipment is designed to operate properly and produce rated capacit y when installed in accordance with accepted industr y standards . F ailure to meet the following conditions ma y result in voiding of the system warranty: System piping must be installed following industr y standards for good piping pr actices. Iner t gas mu ...

  • Heatcraft Refrigeration Products 2500018 - page 12

    T able 9� Specications 1 Motor voltage 208-230/1/60; 1075 RPM 2 Motor voltage 208-230-460/3/60; 1140 RPM NOTE: Model 008-010, 1-2; av ailable in 115/1/60 voltage; model 024-133, 5-26 available in 575/3/60 voltage 12 Part # 2500018 Installation and Operations Manual 18” 22” 13/32” x 1/2” Slots Unit l egs ar e remo vab le fr om un its in ...

  • Heatcraft Refrigeration Products 2500018 - page 13

    Remote Air-Cooled Condenser Installation and Operations Manual, A ugust 2007 13 Remote Air-Cooled C ondenser Electrical junction box is loc ated on header end of units unless optional F AN CYCLING is ordered on 230 and 460 volt. In which c ase, three phase units electrical box is loc ated on unit end opposite header end. 43” 24 1/2” 16” 21 1/ ...

  • Heatcraft Refrigeration Products 2500018 - page 14

    Commercial Refrigeration P ar ts 14 Part # 2500018 Installation and Operations Manual Model Motors F an Blades F an Guards WSS DV T FCB Quantity 230/1/60 230/460/3/60 008 001 1 1 2537974 — 2291820 2318491 009 — 1.5 1 2537974 — 2291820 2318491 010 002 2 1 2537974 — 2291820 2318491 016 003 3 1 2537974 — 2291836 2318491 024 005 5 1 2530355 2 ...

  • Heatcraft Refrigeration Products 2500018 - page 15

    Remote Air-Cooled Condenser Installation and Operations Manual, A ugust 2007 15 Remote Air-Cooled C ondenser Installation Checklist Condenser Star t Up Date Model Number Serial Number Electr ical V oltage Amperage Installer : Name & Addr ess Please retain this inf or mation with the condenser . ...

  • Heatcraft Refrigeration Products 2500018 - page 16

    Since product improv ement is a continuing eort, we reserve the right to make changes in specications without notice. Heatcr af t Refriger ation Products LL C • 2175 West P ark Place Blvd., Stone Mountain, GA 30087 P: 770.465.5600 • F: 770.465.5990 • www .heatcraftrpd.com C L I M A T E C O N T R O L Commercial Refrigeration Parts The na ...

メーカー Heatcraft Refrigeration Products カテゴリー Clothes Dryer

Heatcraft Refrigeration Products 2500018のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 2500018の取扱説明書
- Heatcraft Refrigeration Productsの製品カード
- パンフレット
- またはHeatcraft Refrigeration Products 2500018の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Heatcraft Refrigeration Products 2500018の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Heatcraft Refrigeration Products 2500018の取り付け説明書、サービスマニュアル、簡易説明書、またはHeatcraft Refrigeration Products 2500018のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Heatcraft Refrigeration Products 2500018の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Heatcraft Refrigeration Products 2500018デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHeatcraft Refrigeration Products 2500018を使用するのを助ける技術的文書のことです。説明書は通常、全てのHeatcraft Refrigeration Products 2500018ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Heatcraft Refrigeration Productsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Heatcraft Refrigeration Products 2500018の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHeatcraft Refrigeration Products 2500018の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Heatcraft Refrigeration Products 2500018に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Heatcraft Refrigeration Products 2500018デバイスの基本機能を使うにあたってのヒント。 Heatcraft Refrigeration Products 2500018のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Heatcraft Refrigeration Products 2500018に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHeatcraft Refrigeration Products 2500018のメーカー/サービスへの連絡先に関する情報。

Heatcraft Refrigeration Products 2500018についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHeatcraft Refrigeration Products 2500018の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHeatcraft Refrigeration Products 2500018で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)