Bedienungsanleitung Honeywell 4973 Series

26 Seiten 0.59 mb
Download

Zur Seite of 26

Summary
  • Honeywell 4973 Series - page 1

    Honeywell Field Solutions 04973 Series Conductivity Cells Installation and Maintenance Manual 70-82-25-17 10/07 ...

  • Honeywell 4973 Series - page 2

    ii Installation and Maintenance Manu al 10/07 Copyright, Notices, and Trademarks Printed in U.S.A. – © Copyright 2007 by Honeywell Inc. Revision– 10/07 Warranty/Remedy Honeywell warrants goods of its manufacture as be ing free of defective materials and faulty workmanship. Contact your local sales office for warra nty information. If warranted ...

  • Honeywell 4973 Series - page 3

    10/07 Installation and Maintenance Manual iii About This Document Abstract The purpose of this manual is to support the installa tion and maintenance of t he 4973 Series Conductivity Cells. Revision Notes The following list provides notes concerning all revisions of thi s document. Rev. ID Date Notes 0 10/96 This document is t he initial release of ...

  • Honeywell 4973 Series - page 4

    iv Installation and Main tenance Manual 10/07 Contacts World Wide Web http://hpsweb.honeywel l.com Telephone Contact us by tel ephone at the numbers lis ted below. Organization Phone Number United States and Canada Honeywell 1-800-423-9883 Tech. Support ...

  • Honeywell 4973 Series - page 5

    10/07 Installation and Maintenance Manual v Contents 1. INTRO DUCTION ................................................................................................... 1 1.1 Overview ........................................................................................................................................ 1 1.2 Description .......... ...

  • Honeywell 4973 Series - page 6

    vi Installation an d Maintenance Manual 10/07 Figures Figure 1-1 4973 Type Conductivity Cells, for Fl ow and Insertion-type Applications. _______________ 2 Figure 1-2 Recommended Locations for Mounting a C onductivity Cell __________________________ 3 Figure 1-3 Two Piping Arra ngements for the Cell ___________________________________________ 3 Fig ...

  • Honeywell 4973 Series - page 7

    Introduction 10/07 Installation and Maintenance Manual 1 1. Introduction 1.1 Overview The 4973 Type cells , Figure 1-1, have a rugged configurati on fo r reliable, continuous m easurements of electrolytic conductivity in industria l water processes at temperat ures up to 140 ° C at 250 psig. They are applicable to such measurements as the effluen ...

  • Honeywell 4973 Series - page 8

    Introduction 2 Installation and Mainten ance Man u al 10/07 Un i v e r s a l H e a d ¾” Conduit C ondu ct i v i t y Ce l l Po t t e d Co n n e c t o r Ho u s i ng 11 / 8 " H e x Ac r os s Fl at s 3/ 4 NPT M o ld in g Fl ow Ho l e s Fl ow C hannel Gr a p h i t e E l ect r odes Tef l on Sh e at h FL OW FL OW Ti t ani um El ec t r o de s Inse ...

  • Honeywell 4973 Series - page 9

    Introduction 10/07 Installation and Maintenance Manual 3 P r eferr ed Cel l Loc a t i on s Cool er Pu mp Pr oc es s a/ n 23340 Figure 1-2 Recommended Locations for Mounting a Conductivity Cell Flow (b) Cell M ou nt e d in PES F low C ham be r Flow (a) Cell Mounted in 3 / 4" NPT P ipe Tee* ( Cust omer Supplied) *Maximu m allow able operat ing t ...

  • Honeywell 4973 Series - page 10

    Specifications 4 Installation and Mainten ance Man u al 10/07 2. Specifications 2.1 Specifications for 04973 Series Parameter Description Cell Constant 04973 Series: 0.01, 0.1, 1.0 and 10 as specified Electrode Material 0.01 and 0.1 constant , titanium 1.0 and 10 constant , high density graphite with Teflon sheath Maximum Pressure Limit 1724 kPa (2 ...

  • Honeywell 4973 Series - page 11

    Installation 10/07 Installation and Maintenance Manual 5 3. Installation 3.1 General Requirements Observe the following before install ing a conductivity ce ll. Specifi c requirements for partic ular types of installation are gi ven in Sections 3.3 and 3.4. • Do not remove the Teflon sheath on 1or 10 co nstant cells, as this will change th e cell ...

  • Honeywell 4973 Series - page 12

    Installation 6 Installation and Mainten ance Man u al 10/07 3.3 In-Line Type Mounting In addition to the General Requirements outlined above , note the following with re gard to insertion-type mounting: • Make certain the liqui d head is above the cell location during m easurement. A verti cal insertion (from above) or a horizontal inserti on can ...

  • Honeywell 4973 Series - page 13

    Installation 10/07 Installation and Maintenance Manual 7 3.5 Torque Recommendations For inserting a cell in metal fittings or b ushings - 40 ft-lb maximum . For inserting a cell in plastic fittings or bushings - 10 ft-lb m aximum . Always us e pipe sealant (prefe rably Teflon t ape). 3.6 Dimension Drawings C E LL IN 11 / 2 " (38 m m ) 83 / 4 & ...

  • Honeywell 4973 Series - page 14

    Installation 8 Installation and Mainten ance Man u al 10/07 1.0 25.4 .50 12.7 3.75 95.25 4.0 101.6 4.5 114.3 1.5 38.1 1/8 N PT 4.25 107.9 .875 22.22 8-32 UNC – 2B 250 DE EP 3/4 NPT 1.0 25.4 .50 12.7 3.75 95.25 4.0 101.6 4.5 114.3 1.5 38.1 1/8 N PT 4.25 107.9 .875 22.22 8-32 UNC – 2B 250 DE EP 3/4 NPT Figure 3-2 Dimension Draw ing for 31079198 F ...

  • Honeywell 4973 Series - page 15

    Installation 10/07 Installation and Maintenance Manual 9 "Z" "Y " See Tab l e (154mm ±. 889) 1. 1 " D i a . (2 7. 9m m) C able i s appr ox. 0. 250" ( 6.4mm ) 3/ 4 " NPT 1. 13" Hex ( 29m m) Suf f i x A 00. 1 0. 1 1. 0 10 In ch 3. 3 2. 6 3. 5 3. 5 mm 84 66 89 89 In ch . 703 . 703 . 593 . 593 mm 17. 85 17. 85 1 ...

  • Honeywell 4973 Series - page 16

    Electrical Connections 10 Installation and Maintenance Manu al 10/07 4. Electrical Connections 4.1 Overview The terminal board connections for the various Honeywell m easuring instruments are gi ven in the appropriate Fig u res in this section. To avoid the possibility of AC pickup in the cell lead s, separate them from all AC line-voltage wiring o ...

  • Honeywell 4973 Series - page 17

    Electrical Connections 10/07 Installation and Maintenance Manual 11 Figure 4-2 Installation Diagram, 4973 Cells, with Integral Cable Leads Directly Connected to UDA2182 Analyzer or Connected to Junction Box YELLOW COA X 50 20 OR 50 FT. CABLE LENGTH . Direct Cell to Analy zer Installation NOTES 5. FOR PURE W ATER SAMPLES IN NON-CONDUCTI VE (PLASTIC, ...

  • Honeywell 4973 Series - page 18

    Electrical Connections 12 Installation and Maintenance Manu al 10/07 4.2.2 Model 4973 Series with Integral Cable to APT Series Analyzer/Transmitter 04973 series cells with i ntegral cable leads connected to an APT4000 04973 series cells with i ntegral cable leads connected to an APT2000 Figure 4-3 Model 4973 Series to APT Series Analyzer/Transmitte ...

  • Honeywell 4973 Series - page 19

    Electrical Connections 10/07 Installation and Maintenance Manual 13 4.3 Instrument Wiring for 4973 Cells with Quick Disconnect Cable 4.3.1 Wiring Model 4973 with Qu ick Disconnect Cable to UDA2182 Figure 4-4 Wiring Diagram for 4973 Cells w ith Quick Disconnect Cable Connected to UDA2182 Analyzer 4.3.2 Wiring Model 4973 with Quick Disconnect Cable t ...

  • Honeywell 4973 Series - page 20

    Electrical Connections 14 Installation and Maintenance Manu al 10/07 4.3.3 Wiring Model 4973 with Qu ick Disconnect Cable to APT Figure 4-6 Wiring Diagram for 4973 Cells w ith Quick Disconnect Cable Connected to APT4000 Figure 4-7 Wiring Diagram for 4973 Cells w ith Quick Disconnect Cable Connected to APT2000 NOTE: IGNORE BLUE AND BROWN WIRES. COAX ...

  • Honeywell 4973 Series - page 21

    Maintenance 10/07 Installation and Maintenance Manual 15 5. Maintenance 5.1 Overview The only maintenance that m ay be required is occas ional cleaning. When cl eaning, avoid scratching electrode surfaces. Do not use a brush or pipe cleaner. 5.2 To Clean the Cell The cell will require cleaning if sludge, slime, etc., accumu late in the flow channel ...

  • Honeywell 4973 Series - page 22

    Maintenance 16 Installation and Maintenance Manu al 10/07 5.5 Air Entrapped in Cell Flow Channel If measurem ent errors appear for horizontal mount ings of a 1 or 10 constant cell, it m ay be that air is entrapped in the cell flo w channel. Take on e of the following actio ns to eliminate this problem: • Increase flow to at least 1 gpm. • Rotat ...

  • Honeywell 4973 Series - page 23

    A ccessories and Spare Parts 10/07 Installation and Maintenance Manual 17 6. Accessories and Spare Parts Description Part Number Flow Cell Housing (PES) 055919 Flow Cell Housing (316 SS) 31079198 Junction Box 31316260 Teflon Shield White for 1 const. cell 31021599 Clear for 10 const. cell (see note below) 31018760 Extension Cables for Se nsors w i ...

  • Honeywell 4973 Series - page 24

    Accessories and Spare Parts 18 Installation and Maintenance Manu al 10/07 ...

  • Honeywell 4973 Series - page 25

    ...

  • Honeywell 4973 Series - page 26

    Honeywell Field Solutions 512 Virginia Drive Fort Washington, PA 19034 70-82-25-17 10 07 Printed in USA http://hpsw eb.honeywell.com ...

Produzent Honeywell Kategorie Water System

Dokumente, die wir vom Produzenten des Geräts Honeywell 4973 Series erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Honeywell
- Bedienungsanleitungen 4973 Series
- Produktkarten Honeywell
- Informationsbroschüren
- oder Energieetiketten Honeywell 4973 Series
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Honeywell 4973 Series.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Honeywell 4973 Series, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Honeywell 4973 Series. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Honeywell 4973 Series ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Honeywell 4973 Series, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Honeywell 4973 Series hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Honeywell 4973 Series verständlich ist.

Eine gänzliche Bedienungsanleitung von Honeywell sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Honeywell 4973 Series bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Honeywell 4973 Series befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Honeywell 4973 Series, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Honeywell 4973 Series - die uns die ersten Schritte während der Nutzung von Honeywell 4973 Series erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Honeywell 4973 Series hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Honeywell 4973 Series im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Honeywell 4973 Series?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Honeywell 4973 Series nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Honeywell 4973 Series hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)