    Honeywell Field Solutions 04973 Series Conductivity Cells Installation and Maintenance Manual 70-82-25-17 10/07 ...

  • Honeywell 4973 Series - page 2

    ii Installation and Maintenance Manu al 10/07 Copyright, Notices, and Trademarks Printed in U.S.A. – © Copyright 2007 by Honeywell Inc. Revision– 10/07 Warranty/Remedy Honeywell warrants goods of its manufacture as be ing free of defective materials and faulty workmanship. Contact your local sales office for warra nty information. If warranted ...

  • Honeywell 4973 Series - page 3

    10/07 Installation and Maintenance Manual iii About This Document Abstract The purpose of this manual is to support the installa tion and maintenance of t he 4973 Series Conductivity Cells. Revision Notes The following list provides notes concerning all revisions of thi s document. Rev. ID Date Notes 0 10/96 This document is t he initial release of ...

  • Honeywell 4973 Series - page 4

    iv Installation and Main tenance Manual 10/07 Contacts World Wide Web http://hpsweb.honeywel l.com Telephone Contact us by tel ephone at the numbers lis ted below. Organization Phone Number United States and Canada Honeywell 1-800-423-9883 Tech. Support ...

  • Honeywell 4973 Series - page 5

    10/07 Installation and Maintenance Manual v Contents 1. INTRO DUCTION ................................................................................................... 1 1.1 Overview ........................................................................................................................................ 1 1.2 Description .......... ...

  • Honeywell 4973 Series - page 6

    vi Installation an d Maintenance Manual 10/07 Figures Figure 1-1 4973 Type Conductivity Cells, for Fl ow and Insertion-type Applications. _______________ 2 Figure 1-2 Recommended Locations for Mounting a C onductivity Cell __________________________ 3 Figure 1-3 Two Piping Arra ngements for the Cell ___________________________________________ 3 Fig ...

  • Honeywell 4973 Series - page 7

    Introduction 10/07 Installation and Maintenance Manual 1 1. Introduction 1.1 Overview The 4973 Type cells , Figure 1-1, have a rugged configurati on fo r reliable, continuous m easurements of electrolytic conductivity in industria l water processes at temperat ures up to 140 ° C at 250 psig. They are applicable to such measurements as the effluen ...

  • Honeywell 4973 Series - page 8

    Introduction 2 Installation and Mainten ance Man u al 10/07 Un i v e r s a l H e a d ¾” Conduit C ondu ct i v i t y Ce l l Po t t e d Co n n e c t o r Ho u s i ng 11 / 8 " H e x Ac r os s Fl at s 3/ 4 NPT M o ld in g Fl ow Ho l e s Fl ow C hannel Gr a p h i t e E l ect r odes Tef l on Sh e at h FL OW FL OW Ti t ani um El ec t r o de s Inse ...

  • Honeywell 4973 Series - page 9

    Introduction 10/07 Installation and Maintenance Manual 3 P r eferr ed Cel l Loc a t i on s Cool er Pu mp Pr oc es s a/ n 23340 Figure 1-2 Recommended Locations for Mounting a Conductivity Cell Flow (b) Cell M ou nt e d in PES F low C ham be r Flow (a) Cell Mounted in 3 / 4" NPT P ipe Tee* ( Cust omer Supplied) *Maximu m allow able operat ing t ...

  • Honeywell 4973 Series - page 10

    Specifications 4 Installation and Mainten ance Man u al 10/07 2. Specifications 2.1 Specifications for 04973 Series Parameter Description Cell Constant 04973 Series: 0.01, 0.1, 1.0 and 10 as specified Electrode Material 0.01 and 0.1 constant , titanium 1.0 and 10 constant , high density graphite with Teflon sheath Maximum Pressure Limit 1724 kPa (2 ...

  • Honeywell 4973 Series - page 11

    Installation 10/07 Installation and Maintenance Manual 5 3. Installation 3.1 General Requirements Observe the following before install ing a conductivity ce ll. Specifi c requirements for partic ular types of installation are gi ven in Sections 3.3 and 3.4. • Do not remove the Teflon sheath on 1or 10 co nstant cells, as this will change th e cell ...

  • Honeywell 4973 Series - page 12

    Installation 6 Installation and Mainten ance Man u al 10/07 3.3 In-Line Type Mounting In addition to the General Requirements outlined above , note the following with re gard to insertion-type mounting: • Make certain the liqui d head is above the cell location during m easurement. A verti cal insertion (from above) or a horizontal inserti on can ...

  • Honeywell 4973 Series - page 13

    Installation 10/07 Installation and Maintenance Manual 7 3.5 Torque Recommendations For inserting a cell in metal fittings or b ushings - 40 ft-lb maximum . For inserting a cell in plastic fittings or bushings - 10 ft-lb m aximum . Always us e pipe sealant (prefe rably Teflon t ape). 3.6 Dimension Drawings C E LL IN 11 / 2 " (38 m m ) 83 / 4 & ...

  • Honeywell 4973 Series - page 14

    Installation 8 Installation and Mainten ance Man u al 10/07 1.0 25.4 .50 12.7 3.75 95.25 4.0 101.6 4.5 114.3 1.5 38.1 1/8 N PT 4.25 107.9 .875 22.22 8-32 UNC – 2B 250 DE EP 3/4 NPT 1.0 25.4 .50 12.7 3.75 95.25 4.0 101.6 4.5 114.3 1.5 38.1 1/8 N PT 4.25 107.9 .875 22.22 8-32 UNC – 2B 250 DE EP 3/4 NPT Figure 3-2 Dimension Draw ing for 31079198 F ...

  • Honeywell 4973 Series - page 15

    Installation 10/07 Installation and Maintenance Manual 9 "Z" "Y " See Tab l e (154mm ±. 889) 1. 1 " D i a . (2 7. 9m m) C able i s appr ox. 0. 250" ( 6.4mm ) 3/ 4 " NPT 1. 13" Hex ( 29m m) Suf f i x A 00. 1 0. 1 1. 0 10 In ch 3. 3 2. 6 3. 5 3. 5 mm 84 66 89 89 In ch . 703 . 703 . 593 . 593 mm 17. 85 17. 85 1 ...

  • Honeywell 4973 Series - page 16

    Electrical Connections 10 Installation and Maintenance Manu al 10/07 4. Electrical Connections 4.1 Overview The terminal board connections for the various Honeywell m easuring instruments are gi ven in the appropriate Fig u res in this section. To avoid the possibility of AC pickup in the cell lead s, separate them from all AC line-voltage wiring o ...

  • Honeywell 4973 Series - page 17

    Electrical Connections 10/07 Installation and Maintenance Manual 11 Figure 4-2 Installation Diagram, 4973 Cells, with Integral Cable Leads Directly Connected to UDA2182 Analyzer or Connected to Junction Box YELLOW COA X 50 20 OR 50 FT. CABLE LENGTH . Direct Cell to Analy zer Installation NOTES 5. FOR PURE W ATER SAMPLES IN NON-CONDUCTI VE (PLASTIC, ...

  • Honeywell 4973 Series - page 18

    Electrical Connections 12 Installation and Maintenance Manu al 10/07 4.2.2 Model 4973 Series with Integral Cable to APT Series Analyzer/Transmitter 04973 series cells with i ntegral cable leads connected to an APT4000 04973 series cells with i ntegral cable leads connected to an APT2000 Figure 4-3 Model 4973 Series to APT Series Analyzer/Transmitte ...

  • Honeywell 4973 Series - page 19

    Electrical Connections 10/07 Installation and Maintenance Manual 13 4.3 Instrument Wiring for 4973 Cells with Quick Disconnect Cable 4.3.1 Wiring Model 4973 with Qu ick Disconnect Cable to UDA2182 Figure 4-4 Wiring Diagram for 4973 Cells w ith Quick Disconnect Cable Connected to UDA2182 Analyzer 4.3.2 Wiring Model 4973 with Quick Disconnect Cable t ...

  • Honeywell 4973 Series - page 20

    Electrical Connections 14 Installation and Maintenance Manu al 10/07 4.3.3 Wiring Model 4973 with Qu ick Disconnect Cable to APT Figure 4-6 Wiring Diagram for 4973 Cells w ith Quick Disconnect Cable Connected to APT4000 Figure 4-7 Wiring Diagram for 4973 Cells w ith Quick Disconnect Cable Connected to APT2000 NOTE: IGNORE BLUE AND BROWN WIRES. COAX ...

  • Honeywell 4973 Series - page 21

    Maintenance 10/07 Installation and Maintenance Manual 15 5. Maintenance 5.1 Overview The only maintenance that m ay be required is occas ional cleaning. When cl eaning, avoid scratching electrode surfaces. Do not use a brush or pipe cleaner. 5.2 To Clean the Cell The cell will require cleaning if sludge, slime, etc., accumu late in the flow channel ...

  • Honeywell 4973 Series - page 22

    Maintenance 16 Installation and Maintenance Manu al 10/07 5.5 Air Entrapped in Cell Flow Channel If measurem ent errors appear for horizontal mount ings of a 1 or 10 constant cell, it m ay be that air is entrapped in the cell flo w channel. Take on e of the following actio ns to eliminate this problem: • Increase flow to at least 1 gpm. • Rotat ...

  • Honeywell 4973 Series - page 23

    A ccessories and Spare Parts 10/07 Installation and Maintenance Manual 17 6. Accessories and Spare Parts Description Part Number Flow Cell Housing (PES) 055919 Flow Cell Housing (316 SS) 31079198 Junction Box 31316260 Teflon Shield White for 1 const. cell 31021599 Clear for 10 const. cell (see note below) 31018760 Extension Cables for Se nsors w i ...

  • Honeywell 4973 Series - page 24

    Accessories and Spare Parts 18 Installation and Maintenance Manu al 10/07 ...

  • Honeywell 4973 Series - page 25

    ...

  • Honeywell 4973 Series - page 26

    Honeywell Field Solutions 512 Virginia Drive Fort Washington, PA 19034 70-82-25-17 10 07 Printed in USA http://hpsw eb.honeywell.com ...

Fabbricante Honeywell Categoria Water System

I documenti che otteniamo dal fabbricante del dispositivoHoneywell 4973 Series possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Honeywell
- manuali per l’uso 4973 Series
- schede prodotto Honeywell
- opuscoli
- o etichette energetiche Honeywell 4973 Series
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Honeywell 4973 Series.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Honeywell 4973 Series, manuali di manutenzione, brevi manuali o manuali utente Honeywell 4973 Series. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Honeywell 4973 Series.

Manuali per l’uso simili

Manuale completo del dispositivo Honeywell 4973 Series, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Honeywell 4973 Series dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Honeywell 4973 Series.

Il manuale per l’uso completo Honeywell, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Honeywell 4973 Series - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Honeywell 4973 Series, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Honeywell 4973 Series che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Honeywell 4973 Series - che ci dovrebbe aiutare nei primi passi durante l'uso Honeywell 4973 Series
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Honeywell 4973 Series
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Honeywell 4973 Series in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Honeywell 4973 Series?

Utilizza il modulo sottostante

Se non hai risolto il problema con Honeywell 4973 Series con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Honeywell 4973 Series è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)