Bedienungsanleitung Konica Minolta PULSOX-300

32 Seiten 1.51 mb
Download

Zur Seite of 32

Summary
  • Konica Minolta PULSOX-300 - page 1

    OXYGEN SA TURA TION MONITOR PULSOX -300 ® Instruction Manual This instrument must be used according to the instructions of the doctor . ...

  • Konica Minolta PULSOX-300 - page 2

    Safety Symbols W arnings and precautions noted in this manual and the instrument are indicated by the following markings, designed to prevent accidents caused by erroneous handling of the equipment. This indicates text consisting of a warning or precaution relating to safety . Please read the text carefully and use the equipment safely . This indic ...

  • Konica Minolta PULSOX-300 - page 3

    1 Foreword Safety Precautions T o ensure correct use of this instrument, read the following points carefully and adhere to them. After you have read this manual, keep it in a safe place where it can be referred to anytime a question arises. W ARNING (Failure to adhere to the following points may result in death or serious injury .) The instrument i ...

  • Konica Minolta PULSOX-300 - page 4

    2 Foreword CAUTION (Failure to adhere to the following points may result in injury or damage to the in- strument or other property .) Do not use batteries other than those specified by KONICA MINOL T A SENSING, INC. When installing batteries in the instrument, make sure that they are correctly oriented according to the mark. If alkali uid from t ...

  • Konica Minolta PULSOX-300 - page 5

    3 Foreword Contents Safety Symbols Safety Precautions ............................................................. 1 Foreword ............................................................................4 Safety Notes ........................................................................... 4 Package Contents...................................... ...

  • Konica Minolta PULSOX-300 - page 6

    4 Foreword Foreword Safety Notes CAUTION: U.S.Federal law restricts this device to sale by or on the order of a physician. The instrument is designed for measurement of the oxygen saturation (SpO 2 ) of arterial blood and the pulse rate. Do not use it for any other purposes, such as warning of sleep apnea and breathing abnormalities. The Oxygen Sat ...

  • Konica Minolta PULSOX-300 - page 7

    5 Foreword Package Contents Before using the instrument, make sure that the following items are present. 1) PULSOX-300 main body × 1 2) Wristband WB-300 × 1 3) AAA-size alkaline battery × 1 4) Instruction manuals • PULSOX-300 instruction manual × 1 • Separate manual (Using manual for Probes) × 1 ✻ The probe is optional. About Probe The f ...

  • Konica Minolta PULSOX-300 - page 8

    6 Foreword System Diagrams and Accessories The instrument consists of the following items. 05,3/ 8 Optional accessories Standard accessories Wristband WB-300 AAA-size alkaline battery Finger Clip Probe SR-5C Spot Check Probe SP-5C Monitor Probe LM-5C Personal Probe SD-5C Extension cable EC-300 Standard accessories Optional accessories ...

  • Konica Minolta PULSOX-300 - page 9

    7 Foreword Names of Parts PULSOX-300 Power button Probe connector Wristband Battery cover Used to start/end measurement. Measurement results and messages are displayed. Connect the probe to this connector . Used to set the instrument on your wrist. The cover can be opened by turning it approximately 90 degrees. Display (LED) ...

  • Konica Minolta PULSOX-300 - page 10

    8 Foreword Notes on Use • This instrument should be used under the following operat - ing conditions. • T emperature of 0 to 40°C (32 to 104°F), relative humidity of 30 to 85%, with no condensation. • Atmospheric pressure of 700 to 1060 hPa (altitude of – 400 to 3000m). • This is a precision instrument. T o avoid the possibility of it b ...

  • Konica Minolta PULSOX-300 - page 11

    9 Foreword Differenc e f ro m t he SaO 2 value to displayed value <T able 1> <T able 2> SaO 2 HbCO SaO 2 Methemoglobin 1% 5% 10% 1% 5% 10% 50 50 70 70 90 90 100 100 Measured value is always lower than th e a ctual value. Displayed value is sometimes higher than th e a ctual value if SaO 2 is around 50%. -0.1 -0.7 -1.5 +0.2 +1.3 +3.2 -0. ...

  • Konica Minolta PULSOX-300 - page 12

    10 Foreword Notes on Storage • This instrument should be stored under the following storage conditions. • T emperature of –10 to 60°C (14 to 140°F), relative humid- ity of 10 to 95%, with no condensation. • Atmospheric pressure of 700 to 1060 hPa (altitude of –400 to 3000m). • When storing the instrument: • Do not store the instrume ...

  • Konica Minolta PULSOX-300 - page 13

    11 Foreword Disposal Method • When disposing of the used battery , insulate the polarity ter - minals with insulating tape etc. If the terminals of the battery come into contact with metal objects, heat generation, explo- sion or re may result. • Make sure that the battery is either disposed of or recycled correctly in accordance with local ...

  • Konica Minolta PULSOX-300 - page 14

    12 Preparations Preparations Before starting measurements using this instrument, follow the procedure given below to ensure that measurements are stable. 1) Attaching the Wrist Band Attach the Wrist Band WB-300 (supplied as a standard accessory) to the instrument. Since the WB-300 is made of elastic material, it allows for exibility and comfort ...

  • Konica Minolta PULSOX-300 - page 15

    13 Preparations 4 Pass the other end of the band outward through band xture B. ◆  T ake care not to twist the band. 2) Connecting the probe Connect the probe’s connector plug into the Probe Connector on the instrument. ◆ Make sure that probe’s connector plug is oriented correctly . ◆ Do not connect it in with excessive force. Doing ...

  • Konica Minolta PULSOX-300 - page 16

    14 Preparations 3) Installing the battery Procedure 1 T urn the battery cover clockwise approximately 90 degrees to open the cover . ◆  When turning the cover , keep the flat part of your finger on the cover ’ s catch. This facilitates opening the cover with minimum force. 2 Insert the battery into the battery compartment according to the po ...

  • Konica Minolta PULSOX-300 - page 17

    15 Measurement Measurement 1) Starting the Measurement 1 Attach the probe to a nger of an adult patient. 2 Press the Power button. ● The Power is ON, all the elements on the display are displayed for about 2 seconds, and then the display changes to the measurement display . ◆  Until the measurement value has been calculated and displayed, ...

  • Konica Minolta PULSOX-300 - page 18

    16 Measurement 2) Reading the display When the instrument is turned ON, all the elements of the LED will light up. The pulse level, pulse rate and SpO 2 value are displayed during measurement. Pulse rate (P .R.) If an error occurs, an error message mainly about P .R. will be displayed. Battery indicate Flashing when battery is nearly empty . Pulse ...

  • Konica Minolta PULSOX-300 - page 19

    17 Measurement 3) Ending the Measurement About Auto Power-Off function The instrument has an auto power-off function that operates independently . If no probe is connected to the PULSOX ("C" blinks) or no probe is attached to the patient ("L" blinks) continuously for more than 2 minutes, the Power is automatically switched off. ...

  • Konica Minolta PULSOX-300 - page 20

    18 Check Points T rouble Shootings Error Messages The instrument display error messages when the error occurs. Check and correspond to them correctly . %RROR-ESSAGES #AUSE 3OLUTION s  #ONNECTTHEPROBETOTHE 05,3/8PROPERLY7HENUSING THEOPTIONAL%XTENSION#ABLE %#CONNECTTH ...

  • Konica Minolta PULSOX-300 - page 21

    19 Check Points s  #HECKTHATTHEPROBEISPROPERLY ATTACHEDTO THEPATIENT)FT HEPROBE ISPROPERLYATTACHEDBUTTHIS ME SSAG ES TILL AP PEAR S THE CIR CUL ATIO N INT HEARE ABEING MEASU REDMA YNOT BE GOOD -OV ETH EPRO BETO AN AREA ...

  • Konica Minolta PULSOX-300 - page 22

    20 Check Points %RROR-ESSAGES #AUSE 3OLUTION s  !TTACHTHEPROBETOTHEBODY CORRECTLY)FTHISMESSAGEIS DISPLAYEDWHENTHEUNITISATTACHED TOTHEPATIENTCORRECTLYTHE MEASUREMENTCONDITIONSARE REGARDEDASBLOODCIRCULATIONOR OTHERCIRCULATORYPROBLEMS? ...

  • Konica Minolta PULSOX-300 - page 23

    21 Check Points %RROR-ESSAGES #AUSE 3OLUTION 4HISMESSAGEINDICATESTHATTHE MEASUREDVALUEISOUTSIDETHE ACCURACYGUARANTEEDRANGE s 4HE3P/  VALUEISBELOW THELOWERL IMIT3P/   OFTHEMEASUREMENT RANGE4HEMEASURED VALUEWILLSTILLBE? ...

  • Konica Minolta PULSOX-300 - page 24

    22 Check Points Maintenance and Inspection • Before using the instrument, make sure that there is no dam - age to the instrument, no damage or wire-breakage in the probe cable and the instrument operates correctly and safely . Cleaning • Dampen a soft cloth with neutral detergent or water , wipe the instrument with it, then wipe off carefully w ...

  • Konica Minolta PULSOX-300 - page 25

    23 Appendix Specication ■ Dual-wavelength pulse type (665nm/880nm) arterial blood oxygen satura- tion measuring instrument • Name: Oxygen Saturation Monitor • Model name: PULSOX-300 ■ Functions: • Measuring range: SpO 2 : 0 to 100% SpO 2 Pulse rate: 30 to 230 bpm • Accuracy: SpO 2 : ±2% SpO 2 (70 to 100% range, 1S.D.) Pulse rate: ± ...

  • Konica Minolta PULSOX-300 - page 26

    24 Appendix Probes (SR-5C, SP-5C, LM-5C, SD-5C) ■ LED-SPD probe ■ T ype • Finger Clip Probe SR-5C • Spot Check Probe SP-5C • Monitor Probe LM-5C • Personal Probe SD-5C ✻ It can be used with one of Extension Cable EC-300 ■ Components that touch the body Cover: Polycarbonate Wrist band: Polyethylene terephthalate, nylon 6 Rating namep ...

  • Konica Minolta PULSOX-300 - page 27

    25 Appendix Appendix Calculation Method for Displayed V alues <Pulse level meter> The pulse level meter displays the transmitted light amount ratio calculated by the following equation. The pulse level is indicated in eight levels (0 to 15%, full scale if over 10%). <Oxygen saturation (SpO 2 )> Updates the moving average of the oxygen s ...

  • Konica Minolta PULSOX-300 - page 28

    26 Appendix EMC Guidance Guidance and manufactures declaration - electromagnetic emissions Guidance and manufactures declaration - electromagnetic immunity The Oxygen Saturation Monitor Model PULSO X-300 is intended for use in the electromagnetic environment specified below. The customer or the user of the Model PULSO X-300 should assure tha ...

  • Konica Minolta PULSOX-300 - page 29

    27 Appendix Guidance and manufactures declaration - electromagnetic immunity The Oxygen Saturation Monitor Model PULSO X-300 is intended for use in the electromagnetic environment specified below. The customer or the user of the Model PULSO X-300 should assure that it is used in such anenvironment. Immunity test IEC 60601 T est level Compliance ...

  • Konica Minolta PULSOX-300 - page 30

    28 Appendix ■ Spectral Absorption of Hb and HbO 2 Absorption coefficient Wa velength Red light Infrared light Measurement Principle This instrument measures the oxygen saturation (SpO 2 ) in arte - rial blood and pulse rate continuously in a non-invasive method by applying optical principles. With this instrument, SpO 2 is dened by the followi ...

  • Konica Minolta PULSOX-300 - page 31

    29 Appendix Relation between Oxygen Saturation and Partial Pressure The relation between oxygen saturation (SpO 2 ) and oxygen partial pressure (PaO 2 ) is shown in the graph below. SpO 2 is the oxygen saturation as measured by pulse oximeters. ■ Oxygen Saturation vs. Oxygen Partial Pressure The curve of the above graph may shift to the right or ...

  • Konica Minolta PULSOX-300 - page 32

    AJF AKK Printed in Japan 9222-1732-34 © 2007-2009 KONICA MINOL T A SENSING, INC. Manufacturer 3-91, Daisen-nishimachi, Sakai-ku, Sakai-shi, Osaka 590-8551, Japan ...

Produzent Konica Minolta Kategorie Oxygen Equipment

Dokumente, die wir vom Produzenten des Geräts Konica Minolta PULSOX-300 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Konica Minolta
- Bedienungsanleitungen PULSOX-300
- Produktkarten Konica Minolta
- Informationsbroschüren
- oder Energieetiketten Konica Minolta PULSOX-300
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Konica Minolta PULSOX-300.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Konica Minolta PULSOX-300, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Konica Minolta PULSOX-300. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Konica Minolta PULSOX-300 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Konica Minolta PULSOX-300, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Konica Minolta PULSOX-300 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Konica Minolta PULSOX-300 verständlich ist.

Eine gänzliche Bedienungsanleitung von Konica Minolta sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Konica Minolta PULSOX-300 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Konica Minolta PULSOX-300 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Konica Minolta PULSOX-300, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Konica Minolta PULSOX-300 - die uns die ersten Schritte während der Nutzung von Konica Minolta PULSOX-300 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Konica Minolta PULSOX-300 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Konica Minolta PULSOX-300 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Konica Minolta PULSOX-300?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Konica Minolta PULSOX-300 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Konica Minolta PULSOX-300 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)