765000 AL TERNA TING PRESSURE MA TTRESS SYSTEM WITH ACTIVE SENSOR TECHNOL OGY USER MANUAL Impor tant: Do not operate the Mattress System without rst reading and understanding this manual! Save this manual for future use. Note: The most current version of this manual can be found online at www.grahameld.com 765000-INS-LAB-RevB10 ...
-
Graham Field 765000 - page 2
2 765000-INS-LAB-RevB10 CONTENTS INTRODUCTION ..................................................................................... 3 INTENDED USE OF THIS DEVICE ........................................................ 3 IMPORT ANT SAFETY PRECAUTIONS .................................................. 4 DANGER ....................................... ...
-
Graham Field 765000 - page 3
765000-INS-LAB-RevB10 3 INTRODUCTION Use this manual for set-up and operation of the Lumex ® AltaDyne ® Sensor Plus 765000 Alternating Pr essur e Mattr ess System with Active Sensor T echnology . Read all instructions befor e using the mattr ess system. Save this manual for futur e r efer ence. INTENDED USE OF THIS DEVICE The intended use of the ...
-
Graham Field 765000 - page 4
4 765000-INS-LAB-RevB10 IMPORT ANT SAFETY PRECA UTIONS The safety statements pr esented in this chapter r efer to the basic safety information that should be obser ved by those using this Mattr ess System. Ther e ar e additional safetystatementsinotherchaptersorsections,whichmay bethesameasorsimilarto ...
-
Graham Field 765000 - page 5
765000-INS-LAB-RevB10 5 W ARNING: Always use close supervision when this product is used by , on, or near children or those who require close supervision. W ARNING: Use this product only as intended and described in this manual. Do not use attachments or accessories not recommended by Graham-Field. W ARNING: Never operate this product if: a) It has ...
-
Graham Field 765000 - page 6
6 765000-INS-LAB-RevB10 W ARNING: Patient entrapment with bed side rails may cause injury or death. The bed frame and its components, including the mattress, bed side rails, head and foot board, bedding, and any accessories added to the bed, can all affect the risk of entrapment. Thorough patient assessment and monitoring are necessary to reduce th ...
-
Graham Field 765000 - page 7
765000-INS-LAB-RevB10 7 EQUIPMENT SYMBOLS Manufacturer Indicates that this product is according to the degree of protection against electric shock for type BF equipment Functional earth (for UL only) Attention! Read the instructions! Disposal of Electrical & Electronic Equipment (WEEE): Do not treat this product as household waste. For more det ...
-
Graham Field 765000 - page 8
8 765000-INS-LAB-RevB10 PRODUCT DESCRIPTION PUMP AND MA TTRESS SY STEM pumpandmattresssystem CPRvalves quickconnectors (mattress-pump connectors) mattress footend symbol pump PUMP: FRONT quickconnector front panel PUMP: REAR mainpower switch powercord receptacle fuse hanger filter ...
-
Graham Field 765000 - page 9
765000-INS-LAB-RevB10 9 PUMP: FRONT P ANEL Fr ont panel of pump is shown below . Descriptions of but- tons and indicators follow . T uningbutton; indicatorsatleftofbutton Powerfailureindicator Alarmmutebutton Serviceindicator Power(ON/OFF)button; indicatoratrightofbutton Panellockbutton; indicat ...
-
Graham Field 765000 - page 10
10 765000-INS-LAB-RevB10 Tuning button: Thetuningbuttonne-tunesthe mattr ess system's auto-adjusted pr essur e. Thr ee tuning settings ar e available: 0 System auto-adjusted pr essur e - One level softer than auto-adjusted pr essur e + Onelevelrmerthanauto-adjustedpr essur e Note: The tuning function ...
-
Graham Field 765000 - page 11
765000-INS-LAB-RevB10 11 Maxfir m button: The pump will automatically enter maxrmmodeever ytimethepoweristurnedon.Maxrm mode ensur es the pump is able to r each its maximum oper- atingpr essur e.Maxrmmodewilllastfor20minutes,and then the system will automatically enter auto-adjus ...
-
Graham Field 765000 - page 12
12 765000-INS-LAB-RevB10 Low pr essur e indicator: The low pressur e indicator(yellowLED)illuminates,andthealarmsounds, whenanabnormallylowpr essur eleveloccurs.Ifthelow pr essur e indicator persistently illuminates inappr opriately: 1. Checktoensur eallconnectionsar epr ope ...
-
Graham Field 765000 - page 13
765000-INS-LAB-RevB10 13 INST ALLA TION UNP ACKING 1. Car efullyr emoveallcomponentsfr omthecarton. 2. Inspectallcomponents. 3. Ifdamageisevidenttothecontents,pleasenotifythe carrierandyourGraham-Fieldequipmentpr ovider . PUMP AND MA TTRESS SETUP 1. Removeallshee ...
-
Graham Field 765000 - page 14
14 765000-INS-LAB-RevB10 W ARNING: Locate all cords so that they will not be stepped on, tripped over , or otherwise subjected to damage or stress. W ARNING: Do not use a household extension cord if the electrical cord does not reach the power outlet. Use of an improper extension cord could result in re and electric shock. If an extension cord m ...
-
Graham Field 765000 - page 15
765000-INS-LAB-RevB10 15 OPERA TION GETTING ST AR TED 1. T urnthemainpowerswitch to the ON position. 2. Pr essthefr ontpanelpower button. The power indicator will illuminate. Note: The mattress system will automatically enter maxfirm mode for the quickest inflation at set-up; when inflated, it will then automa ...
-
Graham Field 765000 - page 16
16 765000-INS-LAB-RevB10 TRANSPORT CAP Incaseofpowerfailur eortrans - port:Disconnectthequickconnec - tor and cap the mattr ess with the transport cap to slow deation. Note: This system is equipped with cell-on-cell technology to provide added support and prevent bottoming out in the event of a power failure. Lower ...
-
Graham Field 765000 - page 17
765000-INS-LAB-RevB10 17 MAINTENANCE CLEANING W ARNING: T o reduce the risk of increased bacterial growth, infection, illness, or injury from contamination, thoroughly clean and dry the mattress system before use and as necessary during use as follows: Pump :W ipethepumpwithaclean,dampclothandmild deter gent,and? ...
-
Graham Field 765000 - page 18
18 765000-INS-LAB-RevB10 Fuse replacement tool needed: small screwdriver 1. Ifyoususpectablownfuse,discon - nect the plug fr om the wall outlet immediately . 2. Use a small scr ewdriver to r emove the cover of the fuse holder (fuse lo- cations ar e shown in pictur e at right). 3. Insertanewfuseofthecorre ...
-
Graham Field 765000 - page 19
765000-INS-LAB-RevB10 19 SPECIFICA TIONS Pump Specication Power Supply (Note: see rating label on product) AC 120V 60 Hz 0.17A (for 120V system) Fuse Rating T1A, 250V Cycle time Fixed / 10 minutes Dimensions (L x W x H) 1 1.4" x 7.9" x 4.6" (29.1 x 20 x 11.7 cm) Weight 5 lb (2.2 kg) Environment T emperature Operation: 50°F to 104 ...
-
Graham Field 765000 - page 20
20 765000-INS-LAB-RevB10 LIMITED WARRANTY GFHealthPr oducts,Inc.warrantstheLumex ® AltaDyne ® Sensor Plus 765000 Alternating Pr essur e Mattr ess Sys- tem with Active Sensor T echnology for a period of twelve monthsfordefectsinworkmanshipandmaterials.Ifa pr oductisdeemedtobeunderwarra ...
-
Graham Field 765000 - page 21
765000-INS-LAB-RevB10 21 APPENDIX A: EMC INFORMA TION Guidance and Manufacturer’s De claration- Electromagnetic Emissions: This device is intended for use in the electromagnetic environment specified below. The user of this device should make sure it is used in such an environment. Emissions T est Compliance Electromagnetic Environment-Gui dance ...
-
Graham Field 765000 - page 22
22 765000-INS-LAB-RevB10 Guidance and Manufact urer ’ s Declaration- Electromagn etic Immunity: This device is intended for use in the electromag netic environment specified below . The user of this device should make sure it is used in such an environment. Immunity T est IEC60601 test level Compliance Electromagnetic Environment-Guidance Conduct ...
-
Graham Field 765000 - page 23
765000-INS-LAB-RevB10 23 a The ISM (indu strial, scientific and medica l) bands between 150 kHz and 80 MHz are 6,765 MHz to 6,795 MHz;13,553 MHz to 13,567 MHz; 26,957 MHz to 27,283 MHz; and 40,66 M Hz to 40,70 MHz. b The compliance levels in the ISM frequency bands between 150 kHz and 80 MHz and in the frequency range 80 MHz to 2,5 GHz are intended ...
-
Graham Field 765000 - page 24
USA Corporate Headquar ters: GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 telephone: 800-347-5678, 770-368-4700 fax: 800-726-0601, 678-291-3232 www .grahamfield.com © 2010 GF Health Products, Inc. ...
Haben Sie eine Frage bezüglich Graham Field 765000?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Graham Field 765000 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Graham Field 765000 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.