Bedienungsanleitung Nordyne B5SM -090

16 Seiten 1.72 mb
Download

Zur Seite of 16

Summary
  • Nordyne B5SM -090 - page 1

    LIGHT COMMERCIAL AIR HANDLER Installation Instructions B5SM -090/120 SERIES Horizontal Application - Rear View Horizontal Application - Fr ont View V ertical Application Please read this information thor oughl y and become familiar with the capabilities and use of y our appliance before attempting to operate or maintain this unit. Keep this literat ...

  • Nordyne B5SM -090 - page 2

    2 Important Safety Information ....................................3 General Information ...................................................4 Bef ore Y ou Install this Unit .........................................4 Locating the Air Handler ............................................4 Field Connections f or Electrical P ower Supply ..........4 Air ...

  • Nordyne B5SM -090 - page 3

    3 IMPORT ANT SAFETY INFORMA TION Saf ety markings are used frequently throughout this manual to designate a degree or le v el of seriousness and should not be ignored. W ARNING indicates a potentially hazardous situation that if not av oided, could result in personal injur y or death. CA UTION indicates a potentially hazardous situation that if not ...

  • Nordyne B5SM -090 - page 4

    4 GENERAL INFORMA TION B5SM air handlers are shipped from the f actor y ready f or installation in a horizontal position. The units can be easily re- confi gured in the fi eld for v er tical applications. The return air opening is interchangeable betw een the bottom of the unit and the top panel simply by s witching the fi lter-rack with the ret ...

  • Nordyne B5SM -090 - page 5

    5 AIR HANDLER INST ALLA TION P ackaging Remo v al Remov e the shipping crate and User’ s Manual from the equipment. T ake care not to damage the tubing connections when removing the crate . Minimum Clearance Requirements This air handler must be installed with ample clearance f or easy access to the air fi lters, blo wer assemb ly , and, control ...

  • Nordyne B5SM -090 - page 6

    6 • The B5SM-120 air handler has a dual circuit coil and the B5SM-090 has a single circuit coil. • The B5SM-120 air handler is charged through ser vice v alves on the end of the liquid tube f or each circuit. These must be remo ved bef ore brazing the line sets . The B5SM-090 is charged through a ser vice v alve inside the unit, which should no ...

  • Nordyne B5SM -090 - page 7

    7 ELECTRICAL WIRING W ARNING: T o av oid risk of electrical shock , personal injury , or death, disconn ect all electrical power to the unit before per forming an y maintenance o r s e r v i c e . T h e u n i t m a y h a v e m o r e t h a n o n e electrical suppl y . Lab el all wires prior to disconnection when ser vicing the unit. Wiring errors ca ...

  • Nordyne B5SM -090 - page 8

    8 ST ARTUP AND ADJUSTMENTS Pre-Start Check List Prior to star t-up, complete the f ollo wing inspection:  V erify the unit is lev el and condensate can drain. Check condensate drain line(s) f or proper slope and trap .  V er ify the air handler is mounted securely .  V er ify the surrounding area and top of the unit is free from obstructio ...

  • Nordyne B5SM -090 - page 9

    9 Figure 3. Proper Belt T ension 1/4 inch 1 foot Pulley Alignment Inspect the pulley alignment betw een the motor sheav e and blo wer pulle y . If a misalignment occurs, adjust the location of the motor sheav e b y loosening the set-screw in the stationar y f ace of the motor sheav e. Relocate the sheav e assemb ly on the motor shaft to ensure the ...

  • Nordyne B5SM -090 - page 10

    10 13 5/8" 15 9/16" 17 11/16" 17 13/16" 4 3/16" 4 3/8" 5 11/16" 8 3/16" Air Flow Electrical Connections 2 7/32" 3/4" 1 1/4" 18 13/16" Supply Duct 22 1/16" 19 3/8" 57" Center to Center Field Installed Hanging Rods 28 1/2" C L of Unit 3" C L of Gravity 23" Retur ...

  • Nordyne B5SM -090 - page 11

    11 Figure 5. B5SM Physical Dimensions f or V er tical Installations 23" Return Duct Opening 5 1/16" 53 1/4" Cabinet Height 53" Return Duct Opening 57" Filter Rack Frame 60 1/4" Cabinet Width 18 13/16" Supply Duct Opening 22 1/16" 19 3/8" 27 3/8" Cabinet Depth (without Filter Rack) 2 16 1/4" Sup ...

  • Nordyne B5SM -090 - page 12

    12 Model Motor Sheave P osition External Static Pressures (Inches Water Column) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw B5SM- 090 (2HP) 60 Hz Fully Closed 4182 666 1.28 3961 667 1.20 3706 668 1.11 3436 669 1.03 3081 669 0.93 2738 672 0.83 1 T ur n Open 38 ...

  • Nordyne B5SM -090 - page 13

    13 SINGLE PHASE THREE PHASE G C W2 W1 O/B Y R G C W2 W1 O/B Y R L2 L1 G L3 L2 L1 G L1 L2 G FIELD SUPPL Y CONNECTIONS L1 L2 L3 G FIELD SUPPL Y CONNECTIONS L1 L2 T1 T2 L1 L2 T1 T2 L3 T3 208-230/460V 460 208-230 460 208 - 230 Electrical Configurations 1. Three phase units are factory wired for 460V/60Hz or 380V/50Hz operation. 2. T o reverse motor r o ...

  • Nordyne B5SM -090 - page 14

    14 Figure 7. T ypical Air conditioner Thermostat Connections BLOWER MO TOR GND T O FIELD SUPPLIED DISCONNECT SINGLE ST AGE HEA T/COOL THERMOST A T OUTDOOR SECTION FREEZEST A T SINGLE ST AGE HEA T/COOL THERMOST A T - NO ECONOMIZER AIR HANDLER SECTION TERMINAL BOARD G C W2 W1 O Y R C Y R RC G Y W L1 L2 L3 NOTE: C & W2 t o be connected to electric ...

  • Nordyne B5SM -090 - page 15

    15 Figure 8. T ypical Heat Pump Thermostat Connections BLOWER MO TER GND BLACK BLACK GREEN BRO WN T O FIELD SUPPLIED DISCONNECT SINGLE ST AGE HEA T PUMP THERMOST A T OUTDOOR SECTION NO TE 1 NO TE 2 FREEZEST A T TYPICAL HEA T PUMP THERMOST A T CONNECTION (NO ECONOMIZER) AIR HANDLER SECTION TERMINAL BOARD G C W2 O R Y W1 C Y R G Y E R O B L1 L2 L3 O ...

  • Nordyne B5SM -090 - page 16

    7090950 Specifi cations and illustrations subject to change without notice or incurring obligations. Printed in U.S .A. (01/10) Installed by: Date Installed: Maintenance T ask WM S A A A ir Filters Inspect, c lean or replace as required. x Condensate Drain(s) & Pan Clean condensate drain pan x Inspect the f low of condensate through the drain ...

Produzent Nordyne Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Nordyne B5SM -090 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Nordyne
- Bedienungsanleitungen B5SM -090
- Produktkarten Nordyne
- Informationsbroschüren
- oder Energieetiketten Nordyne B5SM -090
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Nordyne B5SM -090.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Nordyne B5SM -090, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Nordyne B5SM -090. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Nordyne B5SM -090 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Nordyne B5SM -090, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Nordyne B5SM -090 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Nordyne B5SM -090 verständlich ist.

Eine gänzliche Bedienungsanleitung von Nordyne sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Nordyne B5SM -090 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Nordyne B5SM -090 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Nordyne B5SM -090, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Nordyne B5SM -090 - die uns die ersten Schritte während der Nutzung von Nordyne B5SM -090 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Nordyne B5SM -090 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Nordyne B5SM -090 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Nordyne B5SM -090?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Nordyne B5SM -090 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Nordyne B5SM -090 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)