    LIGHT COMMERCIAL AIR HANDLER Installation Instructions B5SM -090/120 SERIES Horizontal Application - Rear View Horizontal Application - Fr ont View V ertical Application Please read this information thor oughl y and become familiar with the capabilities and use of y our appliance before attempting to operate or maintain this unit. Keep this literat ...

  • Nordyne B5SM -090 - page 2

    2 Important Safety Information ....................................3 General Information ...................................................4 Bef ore Y ou Install this Unit .........................................4 Locating the Air Handler ............................................4 Field Connections f or Electrical P ower Supply ..........4 Air ...

  • Nordyne B5SM -090 - page 3

    3 IMPORT ANT SAFETY INFORMA TION Saf ety markings are used frequently throughout this manual to designate a degree or le v el of seriousness and should not be ignored. W ARNING indicates a potentially hazardous situation that if not av oided, could result in personal injur y or death. CA UTION indicates a potentially hazardous situation that if not ...

  • Nordyne B5SM -090 - page 4

    4 GENERAL INFORMA TION B5SM air handlers are shipped from the f actor y ready f or installation in a horizontal position. The units can be easily re- confi gured in the fi eld for v er tical applications. The return air opening is interchangeable betw een the bottom of the unit and the top panel simply by s witching the fi lter-rack with the ret ...

  • Nordyne B5SM -090 - page 5

    5 AIR HANDLER INST ALLA TION P ackaging Remo v al Remov e the shipping crate and User’ s Manual from the equipment. T ake care not to damage the tubing connections when removing the crate . Minimum Clearance Requirements This air handler must be installed with ample clearance f or easy access to the air fi lters, blo wer assemb ly , and, control ...

  • Nordyne B5SM -090 - page 6

    6 • The B5SM-120 air handler has a dual circuit coil and the B5SM-090 has a single circuit coil. • The B5SM-120 air handler is charged through ser vice v alves on the end of the liquid tube f or each circuit. These must be remo ved bef ore brazing the line sets . The B5SM-090 is charged through a ser vice v alve inside the unit, which should no ...

  • Nordyne B5SM -090 - page 7

    7 ELECTRICAL WIRING W ARNING: T o av oid risk of electrical shock , personal injury , or death, disconn ect all electrical power to the unit before per forming an y maintenance o r s e r v i c e . T h e u n i t m a y h a v e m o r e t h a n o n e electrical suppl y . Lab el all wires prior to disconnection when ser vicing the unit. Wiring errors ca ...

  • Nordyne B5SM -090 - page 8

    8 ST ARTUP AND ADJUSTMENTS Pre-Start Check List Prior to star t-up, complete the f ollo wing inspection:  V erify the unit is lev el and condensate can drain. Check condensate drain line(s) f or proper slope and trap .  V er ify the air handler is mounted securely .  V er ify the surrounding area and top of the unit is free from obstructio ...

  • Nordyne B5SM -090 - page 9

    9 Figure 3. Proper Belt T ension 1/4 inch 1 foot Pulley Alignment Inspect the pulley alignment betw een the motor sheav e and blo wer pulle y . If a misalignment occurs, adjust the location of the motor sheav e b y loosening the set-screw in the stationar y f ace of the motor sheav e. Relocate the sheav e assemb ly on the motor shaft to ensure the ...

  • Nordyne B5SM -090 - page 10

    10 13 5/8" 15 9/16" 17 11/16" 17 13/16" 4 3/16" 4 3/8" 5 11/16" 8 3/16" Air Flow Electrical Connections 2 7/32" 3/4" 1 1/4" 18 13/16" Supply Duct 22 1/16" 19 3/8" 57" Center to Center Field Installed Hanging Rods 28 1/2" C L of Unit 3" C L of Gravity 23" Retur ...

  • Nordyne B5SM -090 - page 11

    11 Figure 5. B5SM Physical Dimensions f or V er tical Installations 23" Return Duct Opening 5 1/16" 53 1/4" Cabinet Height 53" Return Duct Opening 57" Filter Rack Frame 60 1/4" Cabinet Width 18 13/16" Supply Duct Opening 22 1/16" 19 3/8" 27 3/8" Cabinet Depth (without Filter Rack) 2 16 1/4" Sup ...

  • Nordyne B5SM -090 - page 12

    12 Model Motor Sheave P osition External Static Pressures (Inches Water Column) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw B5SM- 090 (2HP) 60 Hz Fully Closed 4182 666 1.28 3961 667 1.20 3706 668 1.11 3436 669 1.03 3081 669 0.93 2738 672 0.83 1 T ur n Open 38 ...

  • Nordyne B5SM -090 - page 13

    13 SINGLE PHASE THREE PHASE G C W2 W1 O/B Y R G C W2 W1 O/B Y R L2 L1 G L3 L2 L1 G L1 L2 G FIELD SUPPL Y CONNECTIONS L1 L2 L3 G FIELD SUPPL Y CONNECTIONS L1 L2 T1 T2 L1 L2 T1 T2 L3 T3 208-230/460V 460 208-230 460 208 - 230 Electrical Configurations 1. Three phase units are factory wired for 460V/60Hz or 380V/50Hz operation. 2. T o reverse motor r o ...

  • Nordyne B5SM -090 - page 14

    14 Figure 7. T ypical Air conditioner Thermostat Connections BLOWER MO TOR GND T O FIELD SUPPLIED DISCONNECT SINGLE ST AGE HEA T/COOL THERMOST A T OUTDOOR SECTION FREEZEST A T SINGLE ST AGE HEA T/COOL THERMOST A T - NO ECONOMIZER AIR HANDLER SECTION TERMINAL BOARD G C W2 W1 O Y R C Y R RC G Y W L1 L2 L3 NOTE: C & W2 t o be connected to electric ...

  • Nordyne B5SM -090 - page 15

    15 Figure 8. T ypical Heat Pump Thermostat Connections BLOWER MO TER GND BLACK BLACK GREEN BRO WN T O FIELD SUPPLIED DISCONNECT SINGLE ST AGE HEA T PUMP THERMOST A T OUTDOOR SECTION NO TE 1 NO TE 2 FREEZEST A T TYPICAL HEA T PUMP THERMOST A T CONNECTION (NO ECONOMIZER) AIR HANDLER SECTION TERMINAL BOARD G C W2 O R Y W1 C Y R G Y E R O B L1 L2 L3 O ...

  • Nordyne B5SM -090 - page 16

    7090950 Specifi cations and illustrations subject to change without notice or incurring obligations. Printed in U.S .A. (01/10) Installed by: Date Installed: Maintenance T ask WM S A A A ir Filters Inspect, c lean or replace as required. x Condensate Drain(s) & Pan Clean condensate drain pan x Inspect the f low of condensate through the drain ...

メーカー Nordyne カテゴリー Air Conditioner

Nordyne B5SM -090のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- B5SM -090の取扱説明書
- Nordyneの製品カード
- パンフレット
- またはNordyne B5SM -090の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Nordyne B5SM -090の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Nordyne B5SM -090の取り付け説明書、サービスマニュアル、簡易説明書、またはNordyne B5SM -090のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Nordyne B5SM -090の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Nordyne B5SM -090デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNordyne B5SM -090を使用するのを助ける技術的文書のことです。説明書は通常、全てのNordyne B5SM -090ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Nordyneの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Nordyne B5SM -090の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNordyne B5SM -090の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Nordyne B5SM -090に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Nordyne B5SM -090デバイスの基本機能を使うにあたってのヒント。 Nordyne B5SM -090のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Nordyne B5SM -090に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNordyne B5SM -090のメーカー/サービスへの連絡先に関する情報。

Nordyne B5SM -090についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNordyne B5SM -090の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNordyne B5SM -090で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)