    1 915SA 95 AFUE LEGACY LINE SINGLE - - ST AGE 4- -W A Y M U L T I P O I S E CONDENSING GAS FURNACE Pr oduct Data A11264 The 915S Mult ipoi se Conde nsi ng Ga s Furna ce i s part of the Lega cy Li ne produc t of fe ring. Sporti ng a PSC blowe r motor and an Annua l Fuel U tilization E f ficien cy (AFU E) of 95 .5% , this si ngle -st age ga s fur nac ...

  • Bryant 915S - page 2

    2 SAP ORD ERING NO. CASIN G DIM ENSI ONS (IN.) RA TED HEATI NG OUTPU T† HEATING A IRFLOW COOLING CFM @0 . 5E S P (in WC ) MOTO R HP -S PEED APPROX SHIP WEIGHT (LB) H D W (BTU H) AFUE CFM‡ Heat ing ESP (in. W C) 915SA30040S14 35 29.5 14.2 39,000 95.5% 820 0.10 625-905 1/2 - 4 123 915SA30060S14 35 29.5 14.2 58,000 95.5% 840 0.12 675-1130 1/2 - 4 ...

  • Bryant 915S - page 3

    3 SP ECIFIC A TIONS Heati ng Cap acity and Effi ciency 30040 30060 42060 48080 60080 42100 60100 60120 60140 Input High Heat (BTUH) 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 140,000 Output High Heat (BTUH) 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 135,000 Efficiency AFU E % (ICS) 95.5 95.5 95. 5 95.5 95.5 95.5 95.5 9 ...

  • Bryant 915S - page 4

    4 MODEL NUMBER NOMENCLA TURE 91 5 S A 30 040 S 14 A -- A S - Single Stage T - Two Stage M - Modulating 0 - - - 90 AFUE 3 - - - 93 AFUE 5 - - - 95 AFUE 6 - - - 96 AFUE 7 - - - 97 AFUE S - Standard E - Energy Efficient V - Variable Speed 14 - 14.2” 17 - 17.5” 21 - 21.0” 24 - 24.5” 91 - Legacy 92 - Preferred 98 - Evolution Voltage L - Low NOx ...

  • Bryant 915S - page 5

    5 ACCESSO RIES Part Number Used With Notes KGADC0101BVC A ll 1 KGAVT0701CVT See Ven ti n g T ab les 1 KGAVT0801CVT See Ven ti n g T ab les 1 KGAVT 0101BRA See Venting T ables 1, 2 KGAVT 0201BRA See Venting T ables 1, 2 Part Number Used With Notes KGAHT0201CFP All 7 KGAHT0101CFP All - KGAAD0110PV C All - KGACK0101HCK All DV Horizontal - P908-0001 Al ...

  • Bryant 915S - page 6

    6 AIR DELIVER Y - - CF M (BOTTOM RETURN WITH FIL TER) UNI T SIZE RETURN- AIR CON NECTIO N SPEED TAP S 2 EXT ERNAL STATIC PR ESSU RE (IN. W .C.) 0.1 0. 2 0.3 0.4 0. 5 0.6 0. 7 0.8 0.9 1. 0 30040 SIDE/B OT TO M Black 1100 1055 1010 960 905 850 795 740 685 620 Y ellow 955 915 875 830 790 740 695 645 590 530 Blue 820 795 765 730 695 655 615 570 515 460 ...

  • Bryant 915S - page 7

    7 MAXIMUM EQUIV ALENT VENT LENGTH - - F T . ( M) T able 1 – Maxi mum Equivale nt V e nt Lengt h - - Ft. ( M) 0 to 4500 Ft . (0 t o 1370 M) Al tit ude NOTE: Maxi mum Equiv alent V ent Le ngth (MEVL) i nclude s st andard and conce ntr ic ve nt te rm inat ion and does NOT inc lude e lbows. Us e T abl e 2 - Deduc tions f rom Maximum Equi vale nt V en ...

  • Bryant 915S - page 8

    8 MAXIMUM EQUIV ALENT VENT LENGTH - - F T . ( M) T able 2 – De ducti ons fr om Maximum Equi valent V ent Le ngth - - Ft. (M ) Pipe D iameter ( in): 1- 1 / 2 2 2- 1/ 2 3 4 Mit ered 90º Elbo w 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) Medium Rad ius 90º Elbow 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) Long Rad ius 90º Elbow 3 (0.9) 3 (0.9) 3 (0.9) 3 ...

  • Bryant 915S - page 9

    9 MAXIMUM EQUIV ALENT VENT LENGTH - - FT . (M) ( CONTINUED) T able 3 – Maxi mum Equivale nt V e nt Lengt h - - Ft. ( M) 4501 to 10, 000 Ft. ( 0 to 1370 M) Al tit ude NOTE: Maxi mum Equiv alent V ent Le ngth (MEVL) i nclude s st andard and conce ntr ic ve nt te rm inat ion and does NOT inc lude e lbows. Us e T abl e 2 - Deduc tions f rom Maximum E ...

  • Bryant 915S - page 10

    10 MAXIMUM ALLOW ABLE EXP OSED VENT LENG THS INSULA TION T A BLE - - FT . (M) Maximum Le ngth of Unins ulated and Ins ulated Vent Pip e-Ft ( M) Sing le Stage Fur n ac e Input Winter Des ign Te m p ° F ( ° C ) Pipe Length in Ft. & M No Ins ulati on 3/8-i n. (9.5 mm) Insul atio n 1/ 2-in. ( 12.7 mm) I nsulat ion Pi pe Dia met er -in ches (m m) ...

  • Bryant 915S - page 11

    11 RETURN AIR TEMPERA TURE This f urna ce i s des igned for c ontinuous r et urn- - ai r minim um te mper at ure of 60 _ F( 1 5 _ C ) db o r interm ittent op eration do wn to 5 5 _ F( 1 3 _ C) db su ch as when u sed with a nigh t setback th ermom eter . Return - - air tem peratu re mu st no t exceed 8 0 _ F( 2 7 _ C) d b. Failu re to fo llow th ese ...

  • Bryant 915S - page 12

    12 DOWNFLOW SUB BASE LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D C A 1 1 / 4-IN. TYP PLENUM OPENING FACT ORY-SUPPLIED FIELD-INST ALLED INSULA TION Assembled Disassembled A97427 A88207 DIM ENSI ONS (IN. / MM ) FURNACE CASIN G WIDTH FURNACE IN DOWN FL OW APPLICATION PLEN UM OPEN ING* FLOOR OPENING HOLE NO . FO R WIDTH ADJUSTM ENT A B C D 17 - - - 1 ...

  • Bryant 915S - page 13

    13 MEDIA FIL TER CABINET Media Filter Cabinet A B 16" (406mm) 20" (508mm) 24" (610mm) 17" (432mm) Furnace Side Centerline Screw Slots 23-3/4” 23-3/8” 23-5/8" 5 3 4 Duct Side Opening Opening with Flanges Bent 24-1/4” 25-5/8" B Opening A " (600mm) (594mm) (603mm) (146mm) (651mm) (616mm) 23-1/8” (588mm) 16&qu ...

  • Bryant 915S - page 14

    14 DIMENSIONAL DRA WING A11612 915SA ...

  • Bryant 915S - page 15

    15 GUI DE SPE CIFI CA TIO NS Gen eral Syste m D escrip tion Furni sh a ______________________ 4- - wa y mu lti pois e gas- -fir ed conde nsi ng fur nace f or use wi th nat ura l gas or pr opane (f ac tory- - aut hori ze d conve rs ion ki t re quir ed f or pr opane) ; fur nish c old ai r re tur n pl enum; f urni sh exte rna l medi a cabi net f or us ...

  • Bryant 915S - page 16

    16 Manufacturer reserves the right to discontinue, or change at any time, s pe c ifications or designs without notice and without incur ring ob ligations. E 2012 Bryan t Heating & Cool in g Sys tem s D 7310 W . Mo r ris St. D Indian apolis, IN 46231 Print ed in U .S.A. Edition Date: 01/12 Replaces : NEW Catal og No. PDS 915S A --- 0 1 915SA ...

Produzent Bryant Kategorie Furnace

Dokumente, die wir vom Produzenten des Geräts Bryant 915S erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Bryant
- Bedienungsanleitungen 915S
- Produktkarten Bryant
- Informationsbroschüren
- oder Energieetiketten Bryant 915S
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Bryant 915S.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Bryant 915S, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Bryant 915S. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Bryant 915S ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Bryant 915S, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Bryant 915S hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Bryant 915S verständlich ist.

Eine gänzliche Bedienungsanleitung von Bryant sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Bryant 915S bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Bryant 915S befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Bryant 915S, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Bryant 915S - die uns die ersten Schritte während der Nutzung von Bryant 915S erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Bryant 915S hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Bryant 915S im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Bryant 915S?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Bryant 915S nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Bryant 915S hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)