Manuel d’utilisation Bryant 915S

16 pages 2.62 mb
Télécharger

Aller à la page of 16

Summary
  • Bryant 915S - page 1

    1 915SA 95 AFUE LEGACY LINE SINGLE - - ST AGE 4- -W A Y M U L T I P O I S E CONDENSING GAS FURNACE Pr oduct Data A11264 The 915S Mult ipoi se Conde nsi ng Ga s Furna ce i s part of the Lega cy Li ne produc t of fe ring. Sporti ng a PSC blowe r motor and an Annua l Fuel U tilization E f ficien cy (AFU E) of 95 .5% , this si ngle -st age ga s fur nac ...

  • Bryant 915S - page 2

    2 SAP ORD ERING NO. CASIN G DIM ENSI ONS (IN.) RA TED HEATI NG OUTPU T† HEATING A IRFLOW COOLING CFM @0 . 5E S P (in WC ) MOTO R HP -S PEED APPROX SHIP WEIGHT (LB) H D W (BTU H) AFUE CFM‡ Heat ing ESP (in. W C) 915SA30040S14 35 29.5 14.2 39,000 95.5% 820 0.10 625-905 1/2 - 4 123 915SA30060S14 35 29.5 14.2 58,000 95.5% 840 0.12 675-1130 1/2 - 4 ...

  • Bryant 915S - page 3

    3 SP ECIFIC A TIONS Heati ng Cap acity and Effi ciency 30040 30060 42060 48080 60080 42100 60100 60120 60140 Input High Heat (BTUH) 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 140,000 Output High Heat (BTUH) 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 135,000 Efficiency AFU E % (ICS) 95.5 95.5 95. 5 95.5 95.5 95.5 95.5 9 ...

  • Bryant 915S - page 4

    4 MODEL NUMBER NOMENCLA TURE 91 5 S A 30 040 S 14 A -- A S - Single Stage T - Two Stage M - Modulating 0 - - - 90 AFUE 3 - - - 93 AFUE 5 - - - 95 AFUE 6 - - - 96 AFUE 7 - - - 97 AFUE S - Standard E - Energy Efficient V - Variable Speed 14 - 14.2” 17 - 17.5” 21 - 21.0” 24 - 24.5” 91 - Legacy 92 - Preferred 98 - Evolution Voltage L - Low NOx ...

  • Bryant 915S - page 5

    5 ACCESSO RIES Part Number Used With Notes KGADC0101BVC A ll 1 KGAVT0701CVT See Ven ti n g T ab les 1 KGAVT0801CVT See Ven ti n g T ab les 1 KGAVT 0101BRA See Venting T ables 1, 2 KGAVT 0201BRA See Venting T ables 1, 2 Part Number Used With Notes KGAHT0201CFP All 7 KGAHT0101CFP All - KGAAD0110PV C All - KGACK0101HCK All DV Horizontal - P908-0001 Al ...

  • Bryant 915S - page 6

    6 AIR DELIVER Y - - CF M (BOTTOM RETURN WITH FIL TER) UNI T SIZE RETURN- AIR CON NECTIO N SPEED TAP S 2 EXT ERNAL STATIC PR ESSU RE (IN. W .C.) 0.1 0. 2 0.3 0.4 0. 5 0.6 0. 7 0.8 0.9 1. 0 30040 SIDE/B OT TO M Black 1100 1055 1010 960 905 850 795 740 685 620 Y ellow 955 915 875 830 790 740 695 645 590 530 Blue 820 795 765 730 695 655 615 570 515 460 ...

  • Bryant 915S - page 7

    7 MAXIMUM EQUIV ALENT VENT LENGTH - - F T . ( M) T able 1 – Maxi mum Equivale nt V e nt Lengt h - - Ft. ( M) 0 to 4500 Ft . (0 t o 1370 M) Al tit ude NOTE: Maxi mum Equiv alent V ent Le ngth (MEVL) i nclude s st andard and conce ntr ic ve nt te rm inat ion and does NOT inc lude e lbows. Us e T abl e 2 - Deduc tions f rom Maximum Equi vale nt V en ...

  • Bryant 915S - page 8

    8 MAXIMUM EQUIV ALENT VENT LENGTH - - F T . ( M) T able 2 – De ducti ons fr om Maximum Equi valent V ent Le ngth - - Ft. (M ) Pipe D iameter ( in): 1- 1 / 2 2 2- 1/ 2 3 4 Mit ered 90º Elbo w 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) Medium Rad ius 90º Elbow 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) Long Rad ius 90º Elbow 3 (0.9) 3 (0.9) 3 (0.9) 3 ...

  • Bryant 915S - page 9

    9 MAXIMUM EQUIV ALENT VENT LENGTH - - FT . (M) ( CONTINUED) T able 3 – Maxi mum Equivale nt V e nt Lengt h - - Ft. ( M) 4501 to 10, 000 Ft. ( 0 to 1370 M) Al tit ude NOTE: Maxi mum Equiv alent V ent Le ngth (MEVL) i nclude s st andard and conce ntr ic ve nt te rm inat ion and does NOT inc lude e lbows. Us e T abl e 2 - Deduc tions f rom Maximum E ...

  • Bryant 915S - page 10

    10 MAXIMUM ALLOW ABLE EXP OSED VENT LENG THS INSULA TION T A BLE - - FT . (M) Maximum Le ngth of Unins ulated and Ins ulated Vent Pip e-Ft ( M) Sing le Stage Fur n ac e Input Winter Des ign Te m p ° F ( ° C ) Pipe Length in Ft. & M No Ins ulati on 3/8-i n. (9.5 mm) Insul atio n 1/ 2-in. ( 12.7 mm) I nsulat ion Pi pe Dia met er -in ches (m m) ...

  • Bryant 915S - page 11

    11 RETURN AIR TEMPERA TURE This f urna ce i s des igned for c ontinuous r et urn- - ai r minim um te mper at ure of 60 _ F( 1 5 _ C ) db o r interm ittent op eration do wn to 5 5 _ F( 1 3 _ C) db su ch as when u sed with a nigh t setback th ermom eter . Return - - air tem peratu re mu st no t exceed 8 0 _ F( 2 7 _ C) d b. Failu re to fo llow th ese ...

  • Bryant 915S - page 12

    12 DOWNFLOW SUB BASE LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D C A 1 1 / 4-IN. TYP PLENUM OPENING FACT ORY-SUPPLIED FIELD-INST ALLED INSULA TION Assembled Disassembled A97427 A88207 DIM ENSI ONS (IN. / MM ) FURNACE CASIN G WIDTH FURNACE IN DOWN FL OW APPLICATION PLEN UM OPEN ING* FLOOR OPENING HOLE NO . FO R WIDTH ADJUSTM ENT A B C D 17 - - - 1 ...

  • Bryant 915S - page 13

    13 MEDIA FIL TER CABINET Media Filter Cabinet A B 16" (406mm) 20" (508mm) 24" (610mm) 17" (432mm) Furnace Side Centerline Screw Slots 23-3/4” 23-3/8” 23-5/8" 5 3 4 Duct Side Opening Opening with Flanges Bent 24-1/4” 25-5/8" B Opening A " (600mm) (594mm) (603mm) (146mm) (651mm) (616mm) 23-1/8” (588mm) 16&qu ...

  • Bryant 915S - page 14

    14 DIMENSIONAL DRA WING A11612 915SA ...

  • Bryant 915S - page 15

    15 GUI DE SPE CIFI CA TIO NS Gen eral Syste m D escrip tion Furni sh a ______________________ 4- - wa y mu lti pois e gas- -fir ed conde nsi ng fur nace f or use wi th nat ura l gas or pr opane (f ac tory- - aut hori ze d conve rs ion ki t re quir ed f or pr opane) ; fur nish c old ai r re tur n pl enum; f urni sh exte rna l medi a cabi net f or us ...

  • Bryant 915S - page 16

    16 Manufacturer reserves the right to discontinue, or change at any time, s pe c ifications or designs without notice and without incur ring ob ligations. E 2012 Bryan t Heating & Cool in g Sys tem s D 7310 W . Mo r ris St. D Indian apolis, IN 46231 Print ed in U .S.A. Edition Date: 01/12 Replaces : NEW Catal og No. PDS 915S A --- 0 1 915SA ...

Fabricant Bryant Catégorie Furnace

Les documents que nous recevons du fabricant de l'appareilBryant 915S peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Bryant
- manuels d’utilisations 915S
- fiches produit Bryant
- dépliants
- ou étiquettes-énergie Bryant 915S
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Bryant 915S.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Bryant 915S, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Bryant 915S. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Bryant 915S.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Bryant 915S, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Bryant 915S par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Bryant 915S.

Le manuel d’utilisation complet Bryant, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Bryant 915S - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Bryant 915S, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBryant 915S qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Bryant 915S - qui devraient nous aider dans les premières étapes lors de l'utilisation Bryant 915S
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Bryant 915S
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Bryant 915S dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Bryant 915S?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Bryant 915S, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Bryant 915S il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)