Bedienungsanleitung Emerson AE8-1385

12 Seiten 0.93 mb
Download

Zur Seite of 12

Summary
  • Emerson AE8-1385 - page 1

    1 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN Application Enginee ring BULLE TIN Safety Safety Instructions ................................................................. 2 Safety Icon Explanation ........................................................ 2 Instructions Pertaining to Ris ...

  • Emerson AE8-1385 - page 2

    2 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN Safety Instructions Copeland Scroll ® compressors with CoreSense ™ Diagnostics technology are manufactured according to the latest U.S. and European Safety Standards. Particular emphasis has been placed on the user's safety . Safey ico ...

  • Emerson AE8-1385 - page 3

    3 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN ELECTRICAL SHOCK HAZARD • Disconnect and lock out power before servicing. • Discharge all capacitors before servicing. • Use compressor with grounded system only . • Molded electrical plug must be used when required. • Refer to origi ...

  • Emerson AE8-1385 - page 4

    4 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN INTRODUCTION Overview CoreSense ™ Diagnostics is a breakthrough innovation for troubleshooting residential air conditioning and heat pump systems. The CoreSense Diagnostics module is easily installed in the unit electrical panel near the com ...

  • Emerson AE8-1385 - page 5

    5 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN OPERA TION Compressor Protection The CoreSense Diagnostics module utilizes proprietary algorithms to protect the compressor and system from repeated trips of system pressure controls and the compressor internal overload. The protection termina ...

  • Emerson AE8-1385 - page 6

    6 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN off. This event will cause a lockout of the compressor and indicates that the module is mis-wired or the contactor coil is shorted to ground. NOTICE Code 10 is not speci fi ed on the module label. Resetting Alert Codes When the CoreSense Diag ...

  • Emerson AE8-1385 - page 7

    7 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN ALERT TRIP / LOCK POWER 1 Long Run Time 2 Compressor (Pressure) Trip 3 Pressure Switch Cycling 4 Locked Rotor 5 Compressor (Mod Run) Trip 6 Open Start Circuit 7 Open Run Circuit 8 Welded Contactor 9 Low Voltage DC SOL operating range: 18-28VDC ...

  • Emerson AE8-1385 - page 8

    8 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN 2- S t a g e Th e rmo s tat I ndoor Uni t O utdoor Uni t C R Y1 Y2 C R L Y Y2 L DC So l en o i d S ole noi d CoreSense Hi gh / Low Pr essu re S wi t ch CC C o m p r esso r Conta c t or C R Y1 Y2 L C R Y1 Y2 L Prot Figure 4 Wiring Diagram ...

  • Emerson AE8-1385 - page 9

    9 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN Alert Code Alert Condition Lockout Level Lockout Indication Normal Run Solid Green Normal operation, no trip. N/A N/A Code1 Y ellow Flash 1 Long run time. Compressor is running for more than 18 hours at full load. (Code1 is disabled in Heat Pu ...

  • Emerson AE8-1385 - page 10

    10 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN Status Description T roubleshooting Information Solid Green “RUN” Module has power and operating normally Supply voltage is present at module terminals Solid Red “TRIP” Thermostat demand signal Y is present, but the compressor is not ...

  • Emerson AE8-1385 - page 11

    11 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN Y ellow “ALERT” Flash Code 4 Locked Rotor 1. Run capacitor has failed 2. Low line voltage (contact utility if voltage at disconnect is low) • Check wiring connections 3. Excessive liquid refrigerant in compressor 4. Compressor bearings ...

  • Emerson AE8-1385 - page 12

    12 © 201 1 Emerson Climate T echnologies Printed in the U.S.A. AE8-1385 Application Enginee ring BULLE TIN Red “LOCKOUT” Flash Code 5 Y ellow Off Compressor (Moderate Run) T rip Compressor is locked out after 4 consecutive or 10 total compressor (moderate run) trip events 1. Evaporator blower is not running • Check blower relay coil and cont ...

Produzent Emerson Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Emerson AE8-1385 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Emerson
- Bedienungsanleitungen AE8-1385
- Produktkarten Emerson
- Informationsbroschüren
- oder Energieetiketten Emerson AE8-1385
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Emerson AE8-1385.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Emerson AE8-1385, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Emerson AE8-1385. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Emerson AE8-1385 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Emerson AE8-1385, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Emerson AE8-1385 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Emerson AE8-1385 verständlich ist.

Eine gänzliche Bedienungsanleitung von Emerson sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Emerson AE8-1385 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Emerson AE8-1385 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Emerson AE8-1385, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Emerson AE8-1385 - die uns die ersten Schritte während der Nutzung von Emerson AE8-1385 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Emerson AE8-1385 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Emerson AE8-1385 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Emerson AE8-1385?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Emerson AE8-1385 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Emerson AE8-1385 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)