    GB 1 mmHg 60 80 100 120 140 160 180 200 220 / min 2 1 21.2 22.2 85 90 158 92 110 155 93 112 10:05 10:12 x x x x x x LOG BOOK : Age: Weight: kg/lbs ...

  • Oregon Scientific BPW128 - page 2

    2 GB BOLD BOLD LEYENDA : - INCREMENTO RÁPIDO - DESTELLANDO - PULSAR BOTÓN - PULSAR MANTENER OPRIMIDO EL BOTÓN ES BOLD BOLD LEGEND : - FAST INCREMENT - FLASHING - PRESS BUTTON - PRESS AND HOLD BUTTON GB BOLD BOLD LEGENDE : - AUGMENTATON RAPIDE - CLIGNOTEMENT - APPUYER SUR LE BOUTON - APPUYER SANS LACHER SUR LE BOUTON F ...

  • Oregon Scientific BPW128 - page 3

    GB 3 INFORMATION CONCERNING THE CE SYMBOL This device complies with the European regulations based on the Medical Products Code, and bears the CE mark “CE0123”. The device has been quality inspected according to EG guideline 93/42/EWG and tested in compliance to the EN1060-1 Non-invasive sphygmomanometers-Part 1, General requirements and EN1060 ...

  • Oregon Scientific BPW128 - page 4

    4 GB DESCRIPTION AND FUNCTION OF PARTS A. Liquid Crystal Display (LCD) and protective cover - Large easy-reading display - 5 functional symbols - Systolic [SYS/mmHg], Diastolic [DIA/mmHg], Mean [MAP/mmHg], Pulse [pul/min.]and date & time display. B. Battery compartment Houses two (2) LR03 /AAA/ UM4 size 1.5V batteries C. Button - For time adjus ...

  • Oregon Scientific BPW128 - page 5

    GB 5 DISPLAY-SYMBOL DESCRIPTION Memory Mark Weak Battery Inflating Mark Air releasing Pulse Mark INSTALLING BATTERIES 1. Slide battery cover off. 2. Install batteries first. Ensure correct polarity. Battery Type: 2 Alkaline LR03 (AAA)size 3. Replace the cover. Replace the batteries if: 1. the weak battery mark appears in the display 2. nothing appe ...

  • Oregon Scientific BPW128 - page 6

    6 GB PROPER EQUIPMENT SETUP 1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff sh ould be wrapped on bare skin for correct measurements. 2. Apply cuff to left wrist with palm facing up. 3. Make sure the edge of the cuff is about 1 cm from the plam. 4. In order to ensure accur ...

  • Oregon Scientific BPW128 - page 7

    GB 7 WHAT IS MEAN ARTERIAL PRESSURE (MAP) The Mean Arterial Pressure is the average pressure forcing blood through the arteries. It is not the average of the systolic and diastolic blood pressure. It corresponds to a state of balance between the compressive and expansive forces acting on the arterial wall when there is no distension of the arterial ...

  • Oregon Scientific BPW128 - page 8

    8 GB MEASUREMENT With the individual in a sitting position and with the cuff attached as previously mentioned, a blood pressure reading can be obtained. Note: - For accurate pressure measurement, take blood-pressure readings in a seated position. Avoid leaning back while the measurement is being taken. - Ensure that the lower arm is raised so that ...

  • Oregon Scientific BPW128 - page 9

    GB 9 HOW TO TAKE MEASUREMENT Refer to Fig1 Fig1 2sec Fig1 ...

  • Oregon Scientific BPW128 - page 10

    10 GB Note: 1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff should be wrapped on bare skin for correct measurements. 2. Apply cuff to left wrist with palm facing up. 3. Make sure the edge of the cuff is about 1 cm from the plam. 4. In order to ensure accurate measurements, ...

  • Oregon Scientific BPW128 - page 11

    GB 11 HOW TO SET THE TIME Refer to Fig3 Fig 3 mode ...

  • Oregon Scientific BPW128 - page 12

    12 GB AUTOMATIC POWER OFF The device will automatically switch off after about 1 minute. However, to conserve battery power, press the button whe n finished to turn the unit off. ERROR MESSAGES Display Err 1 Err 2, 8, 12, 13, 14, 15 Err 3 Err 4 Err 5, 6, 7 Err 9, 10,11 Description Deflation period too long Incorrect measurement Cuff is not fastened ...

  • Oregon Scientific BPW128 - page 13

    GB 13 SPECIFICATIONS Measuring method : Oscillometric / non-invasive Application : Adults Measurement location : Wrist section of lower arm Circumference (approx. ) 5.3"-7.7"(13.5-19.5cm) Pressure Measuring range : 30 - 280mmHg Pulse Measuring Range : 30 - 200 pulse/min Accuracy : (Pressure) +/- 3mmHg (Pulse) +/- 5% Operating environment ...

  • Oregon Scientific BPW128 - page 14

    14 GB Should you require assistance regarding this product and its operation, please contact our Customer Care Department at 1-800-853-8883 or via email at helpme@oscientific.com. WARRANTY This product is warranted to be free of manufacturing defects for a period of 12 months from date of retail purchase. Defective product should be directed to the ...

  • Oregon Scientific BPW128 - page 15

    GB 15 measurement again, ensure that the cuff is properly attached, the arm is in the proper position and that movement has been minimized during the measurement process. If the device does not function: - Check that the unit is on. After about 3 minutes of inactivity, the unit will automatically turn off. - Ensure that batteries are properly inser ...

Produzent Oregon Scientific Kategorie Blood Pressure Monitor

Dokumente, die wir vom Produzenten des Geräts Oregon Scientific BPW128 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Oregon Scientific
- Bedienungsanleitungen BPW128
- Produktkarten Oregon Scientific
- Informationsbroschüren
- oder Energieetiketten Oregon Scientific BPW128
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Oregon Scientific BPW128.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Oregon Scientific BPW128, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Oregon Scientific BPW128. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Oregon Scientific BPW128 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Oregon Scientific BPW128, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Oregon Scientific BPW128 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Oregon Scientific BPW128 verständlich ist.

Eine gänzliche Bedienungsanleitung von Oregon Scientific sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Oregon Scientific BPW128 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Oregon Scientific BPW128 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Oregon Scientific BPW128, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Oregon Scientific BPW128 - die uns die ersten Schritte während der Nutzung von Oregon Scientific BPW128 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Oregon Scientific BPW128 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Oregon Scientific BPW128 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Oregon Scientific BPW128?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Oregon Scientific BPW128 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Oregon Scientific BPW128 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)