Manual de instrucciones Oregon Scientific BPW128

15 de páginas 0.51 mb
Descargar

Pasar a la página of 15

Summary
  • Oregon Scientific BPW128 - page 1

    GB 1 mmHg 60 80 100 120 140 160 180 200 220 / min 2 1 21.2 22.2 85 90 158 92 110 155 93 112 10:05 10:12 x x x x x x LOG BOOK : Age: Weight: kg/lbs ...

  • Oregon Scientific BPW128 - page 2

    2 GB BOLD BOLD LEYENDA : - INCREMENTO RÁPIDO - DESTELLANDO - PULSAR BOTÓN - PULSAR MANTENER OPRIMIDO EL BOTÓN ES BOLD BOLD LEGEND : - FAST INCREMENT - FLASHING - PRESS BUTTON - PRESS AND HOLD BUTTON GB BOLD BOLD LEGENDE : - AUGMENTATON RAPIDE - CLIGNOTEMENT - APPUYER SUR LE BOUTON - APPUYER SANS LACHER SUR LE BOUTON F ...

  • Oregon Scientific BPW128 - page 3

    GB 3 INFORMATION CONCERNING THE CE SYMBOL This device complies with the European regulations based on the Medical Products Code, and bears the CE mark “CE0123”. The device has been quality inspected according to EG guideline 93/42/EWG and tested in compliance to the EN1060-1 Non-invasive sphygmomanometers-Part 1, General requirements and EN1060 ...

  • Oregon Scientific BPW128 - page 4

    4 GB DESCRIPTION AND FUNCTION OF PARTS A. Liquid Crystal Display (LCD) and protective cover - Large easy-reading display - 5 functional symbols - Systolic [SYS/mmHg], Diastolic [DIA/mmHg], Mean [MAP/mmHg], Pulse [pul/min.]and date & time display. B. Battery compartment Houses two (2) LR03 /AAA/ UM4 size 1.5V batteries C. Button - For time adjus ...

  • Oregon Scientific BPW128 - page 5

    GB 5 DISPLAY-SYMBOL DESCRIPTION Memory Mark Weak Battery Inflating Mark Air releasing Pulse Mark INSTALLING BATTERIES 1. Slide battery cover off. 2. Install batteries first. Ensure correct polarity. Battery Type: 2 Alkaline LR03 (AAA)size 3. Replace the cover. Replace the batteries if: 1. the weak battery mark appears in the display 2. nothing appe ...

  • Oregon Scientific BPW128 - page 6

    6 GB PROPER EQUIPMENT SETUP 1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff sh ould be wrapped on bare skin for correct measurements. 2. Apply cuff to left wrist with palm facing up. 3. Make sure the edge of the cuff is about 1 cm from the plam. 4. In order to ensure accur ...

  • Oregon Scientific BPW128 - page 7

    GB 7 WHAT IS MEAN ARTERIAL PRESSURE (MAP) The Mean Arterial Pressure is the average pressure forcing blood through the arteries. It is not the average of the systolic and diastolic blood pressure. It corresponds to a state of balance between the compressive and expansive forces acting on the arterial wall when there is no distension of the arterial ...

  • Oregon Scientific BPW128 - page 8

    8 GB MEASUREMENT With the individual in a sitting position and with the cuff attached as previously mentioned, a blood pressure reading can be obtained. Note: - For accurate pressure measurement, take blood-pressure readings in a seated position. Avoid leaning back while the measurement is being taken. - Ensure that the lower arm is raised so that ...

  • Oregon Scientific BPW128 - page 9

    GB 9 HOW TO TAKE MEASUREMENT Refer to Fig1 Fig1 2sec Fig1 ...

  • Oregon Scientific BPW128 - page 10

    10 GB Note: 1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff should be wrapped on bare skin for correct measurements. 2. Apply cuff to left wrist with palm facing up. 3. Make sure the edge of the cuff is about 1 cm from the plam. 4. In order to ensure accurate measurements, ...

  • Oregon Scientific BPW128 - page 11

    GB 11 HOW TO SET THE TIME Refer to Fig3 Fig 3 mode ...

  • Oregon Scientific BPW128 - page 12

    12 GB AUTOMATIC POWER OFF The device will automatically switch off after about 1 minute. However, to conserve battery power, press the button whe n finished to turn the unit off. ERROR MESSAGES Display Err 1 Err 2, 8, 12, 13, 14, 15 Err 3 Err 4 Err 5, 6, 7 Err 9, 10,11 Description Deflation period too long Incorrect measurement Cuff is not fastened ...

  • Oregon Scientific BPW128 - page 13

    GB 13 SPECIFICATIONS Measuring method : Oscillometric / non-invasive Application : Adults Measurement location : Wrist section of lower arm Circumference (approx. ) 5.3"-7.7"(13.5-19.5cm) Pressure Measuring range : 30 - 280mmHg Pulse Measuring Range : 30 - 200 pulse/min Accuracy : (Pressure) +/- 3mmHg (Pulse) +/- 5% Operating environment ...

  • Oregon Scientific BPW128 - page 14

    14 GB Should you require assistance regarding this product and its operation, please contact our Customer Care Department at 1-800-853-8883 or via email at helpme@oscientific.com. WARRANTY This product is warranted to be free of manufacturing defects for a period of 12 months from date of retail purchase. Defective product should be directed to the ...

  • Oregon Scientific BPW128 - page 15

    GB 15 measurement again, ensure that the cuff is properly attached, the arm is in the proper position and that movement has been minimized during the measurement process. If the device does not function: - Check that the unit is on. After about 3 minutes of inactivity, the unit will automatically turn off. - Ensure that batteries are properly inser ...

Fabricante Oregon Scientific Categoría Blood Pressure Monitor

Los documentos del dispositivo Oregon Scientific BPW128 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Oregon Scientific
- manuales de instrucciones BPW128
- hojas de producto Oregon Scientific
- folletos informativos
- o etiquetas energéticas Oregon Scientific BPW128
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Oregon Scientific BPW128.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Oregon Scientific BPW128, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Oregon Scientific BPW128. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Oregon Scientific BPW128.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Oregon Scientific BPW128, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Oregon Scientific BPW128. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Oregon Scientific BPW128.

El manual de instrucciones completo de Oregon Scientific debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Oregon Scientific BPW128 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Oregon Scientific BPW128, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Oregon Scientific BPW128 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Oregon Scientific BPW128 - que deben facilitarnos los primeros pasos durante el uso de Oregon Scientific BPW128
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Oregon Scientific BPW128
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Oregon Scientific BPW128 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Oregon Scientific BPW128?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Oregon Scientific BPW128, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Oregon Scientific BPW128 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)