    Limited Warranty & Limit ation Of Liabilit y This Fluke product will be free from defects in material an d workmans hip for 3 years from the d ate of purchas e. This war- ranty does n ot cover fuses , disposab le batter ies or damage from acc ident, neglec t, misuse or a bnormal c onditions o f opera- tion or handl ing. Res ellers are no t auth ...

  • Fluke 53 & 54 Series - page 3

    i Table of Contents Title Page Safety Informat ion.......................................................................................................... 1 Contacting Fluk e ....................................................................................................... 1 Getting Starte d................................................... ...

  • Fluke 53 & 54 Series - page 4

    53 & 54 Ser ies II Users M anual ii Displaying Tem peratures........................................................................................... 14 Holding the Dis played Tempera tures ........................................................................ 14 Viewing the MIN, MAX, a nd AVG Readings ...................................... ...

  • Fluke 53 & 54 Series - page 5

    1 53 & 54 Series II Safety Informa tion The Fluke M odel 53 and M odel 54 T hermometers (“the thermometer”) ar e microproc essor-based, digital thermometers des igned t o use exter nal J-, K-, T-, E-, R- , S-, and N-type thermocouples (temperatur e probes ) as temperature s ensors. Use the thermom eter on ly as s pecified in t his manua l. ...

  • Fluke 53 & 54 Series - page 6

    53 & 54 Ser ies II Users M anual 2 Table 1. Safet y Information W Warning A Warning identifies co nditions an d actions that po se hazards to th e user. To avoid electrical shoc k or personal injury, follow these guidel ines: • Before usin g the thermo meter inspect the case. Do not use the th ermometer if it appears da maged. Look for cracks ...

  • Fluke 53 & 54 Series - page 7

    53 & 54 Ser ies II Safety Informat ion 3 Table 1. Safet y Information (cont.) W Warning (cont.) • Model 54: Mea surement erro rs may occur if voltages on the me asurement sur faces result in potentials greater than 1 V b etween the two ther mocouples. When potent ial differences are anticipat ed between the thermocouples, use electrically in ...

  • Fluke 53 & 54 Series - page 8

    53 & 54 Ser ies II Users M anual 4 Table 2. Internation al Symbols W Refer to the man ual for i nformat ion about th is feature. P Complies w ith Europ ean Union direc tives. M Battery. Complies with relev ant Can adian Sta ndards Assoc iation direct ives. Getting Started Everything in this Users M anual applies both t o Models 53 and 54 unl es ...

  • Fluke 53 & 54 Series - page 9

    53 & 54 Ser ies II Getting Starte d 5 Components xx 3 4 5 1 2 6 7 aat01f.eps Figure 1. Components Table 3. Components A Thermocoupl e T1 input B Model 54: Thermoc ouple T2 inp ut C Holster D Displ ay E Buttons F Battery door G Batteries ...

  • Fluke 53 & 54 Series - page 10

    53 & 54 Ser ies II Users M anual 6 Display Element s xx 1 12 11 2 3 4 5 7 6 8 9 10 aat02f.eps Figure 2. Display Ele ments Table 4. Displ ay Element s A The thermoc ouple measurem ent includ es an offset. See "Cha nging Set up Options." B The display ed read ings do not c hange. C A shift functi on is in pr ogress. D Readings are being ...

  • Fluke 53 & 54 Series - page 11

    53 & 54 Ser ies II Getting Starte d 7 Buttons Table 5. Buttons A Press A to turn the th ermometer on or off. G (Shift function) Press G , M (CANCEL) to stop d isplaying the m inimum , maximum , and average re adings in the secondary display. Press G , J (CLEAR MEMO RY) to delete log ged readings from memory . Press G , r (PC/IR SEND) to toggle ...

  • Fluke 53 & 54 Series - page 12

    53 & 54 Ser ies II Users M anual 8 Table 5. Buttons (cont .) h Press h to freeze or unfreez e the dis played rea dings. Press h when turning on the therm ometer to test the display . All display elements a ppear. T Model 54: Press T to t oggle showi ng the T 1, T2, and T1-T 2 (differentia l temper ature meas urement) in the primary or secondary ...

  • Fluke 53 & 54 Series - page 13

    53 & 54 Ser ies II Using the Thermometer 9 Using the Thermometer 1. Plug the thermocoupl e(s) into the input conn ector(s). 2. Press A to turn on the therm ometer. After 1 second the thermometer display s the first re ading. If no thermoc ouple is p lugged into the se lected inpu t or the thermocoupl e is "open, " the d isplay s hows ...

  • Fluke 53 & 54 Series - page 14

    53 & 54 Ser ies II Users M anual 10 Changing the Logging Interval The logging interval det ermines how often th e thermometer stores logged rea dings in m emory. You choose the length of the logging interval. S ee "Us ing Memory. " The thermom eter stores logged readin gs at the en d of each loggin g interval. Y ou can s elect a l ogg ...

  • Fluke 53 & 54 Series - page 15

    53 & 54 Ser ies II Changing Se tup Options 11 Changing the Thermocouple Type 1. Press K or N until the displ ay shows TYPE . 2. Press E to display the thermocouple type choic es. The currently selected t hermoc ouple blink s. 3. Press K or N until the thermoc ouple yo u want appears on th e display . 4. Press E to store the therm ocouple ty pe ...

  • Fluke 53 & 54 Series - page 16

    53 & 54 Ser ies II Users M anual 12 Enabling or Disabling Sleep Mode The thermom eter enters sleep m ode if no button pr ess occurs for 20 minutes. Pressing any button wakes the therm ometer and ret urns it to its previ ous state. 1. Press K or N until the displ ay show s SLP . 2. Press E to indicate tha t you want to change the sleep setti ng. ...

  • Fluke 53 & 54 Series - page 17

    53 & 54 Ser ies II Measuring T emperatur es 13 Changing the Line Frequency For optimum rejection of line nois e, set the th ermometer for the local line fre quency as follows: 1. Press K or N until the displ ay show s Li ne . 2. Press E to indicate tha t you want to change the line sett ing. 3. Press K or N as needed unti l the dis play s hows ...

  • Fluke 53 & 54 Series - page 18

    53 & 54 Ser ies II Users M anual 14 Displaying Temperatures 1. Press C to select the correc t temperature s cale. 2. Hold or attach the t hermocoupl e(s) to the measurem ent location. The temperatur e readin g appears i n the s elected disp lay. 3. Model 54: Press T to togg le betwee n showing th e T1, T2, and T1-T 2 readin g in the prim ary or ...

  • Fluke 53 & 54 Series - page 19

    53 & 54 Ser ies II Using Memory 15 Using the Offset to Adjust for Probe Errors Use the offset option in Setup to ad just the therm ometer’ s readings to c ompensat e for the errors of a spec ific thermocoupl e. 1. Plug the thermocoupl e into the i nput connec tor. 2. Place the thermocoup le in a kn own, stab le temperature env ironment (s uch ...

  • Fluke 53 & 54 Series - page 20

    53 & 54 Ser ies II Users M anual 16 Initial Conditions and Data Entrie s Logged readin gs inclu de initial c ondit ions and data entries . The initial c onditions are the therm ocouple ty pe and the offsets for eac h thermoc ouple inpu t. You can on ly view initial con ditions using FlukeView Forms . The data entri es are a tim e stamp, th e T1 ...

  • Fluke 53 & 54 Series - page 21

    53 & 54 Ser ies II Using Memory 17 Clearing Memo ry When memory is full, FULL appears on the display and logging sto ps. You can c lear memory in normal or MI N MAX mode. • Press G , J (CLEAR MEMORY) to delete logged readi ngs from m emory. The display shows the follow ing for 2 s econds. MEMORY cW f Viewing Logged Readings 1. Press r to view ...

  • Fluke 53 & 54 Series - page 22

    53 & 54 Ser ies II Users M anual 18 3. Press M to step through the mi nimum, m aximum, average, and c urrent logg ed reading. F or example , Figure 4 shows the max imum reading in m emory. Th e maximum reading occurred at 1:49 P.M. and was stored in m emory location 5. aat04f.eps Figure 4. Maximu m Reading 4. Press r to stop view ing logged r e ...

  • Fluke 53 & 54 Series - page 23

    53 & 54 Ser ies II Maintenanc e 19 Maintenanc e Replacing the Batteries Refer to the safe ty informat ion in T able 1 befor e replacing the batteries . 1. Turn off the thermometer if neces sary. 2. Loosen the screw and remov e the battery door. 3. Replace the three AA batteries. 4. Replace the battery do or and ti ghten the s crew. Cleaning the ...

  • Fluke 53 & 54 Series - page 24

    53 & 54 Ser ies II Users M anual 20 Genera l Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 c m × 16.2 cm (1.1 in × 3 i n × 6.4 in) Battery 3 AA batteries Certification P , s Safety CSA C22.2 No. 101 0.1 1992 EN 61010 Amendm ents 1, 2 CAT I OVERVOLTAGE (Installation) CATEGOR Y I, Pollution Degree 2 per IEC1010-1* * Refers to ...

  • Fluke 53 & 54 Series - page 25

    53 & 54 Ser ies II Replacement P arts and Acc essories 21 Electrica l (cont.) Measuremen t Accurac y , T1, T2 or T1-T2 (Model 54) J-, K-, T-, E-, and N-ty pe: ± [0.0 5 % of reading + 0. 3 o C (0.5 o F)] [ below − 100 o C ( − 148 o F ) : add 0. 15 % of reading for J -, K-, E-, and N-ty pe; and 0.45 % of re ading f or T-type] R- and S-type: ...

  • Fluke 53 & 54 Series - page 26

    53 & 54 Ser ies II Users M anual 22 ...

Produzent Fluke Kategorie Thermometer

Dokumente, die wir vom Produzenten des Geräts Fluke 53 & 54 Series erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Fluke
- Bedienungsanleitungen 53 & 54 Series
- Produktkarten Fluke
- Informationsbroschüren
- oder Energieetiketten Fluke 53 & 54 Series
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Fluke 53 & 54 Series.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Fluke 53 & 54 Series, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Fluke 53 & 54 Series. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Fluke 53 & 54 Series ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Fluke 53 & 54 Series, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Fluke 53 & 54 Series hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Fluke 53 & 54 Series verständlich ist.

Eine gänzliche Bedienungsanleitung von Fluke sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Fluke 53 & 54 Series bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Fluke 53 & 54 Series befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Fluke 53 & 54 Series, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Fluke 53 & 54 Series - die uns die ersten Schritte während der Nutzung von Fluke 53 & 54 Series erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Fluke 53 & 54 Series hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Fluke 53 & 54 Series im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Fluke 53 & 54 Series?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Fluke 53 & 54 Series nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Fluke 53 & 54 Series hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)