Bedienungsanleitung Hearth and Home Technologies COLBAY-FS-B

49 Seiten 2.96 mb
Download

Zur Seite of 49

Summary
  • Hearth and Home Technologies COLBAY-FS-B - page 1

    R COLUMBIA BA Y DIRECT VENT GAS APPLIANCE Owner ’ s Manual Installation and Operation Model: COLBA Y -FS-B O-T L T ested and Listed by Portland Oregon USA OMNI-T est Laboratories, Inc. C US DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and ope ...

  • Hearth and Home Technologies COLBAY-FS-B - page 2

    Page 2 Quadra-Fire • Columbia Bay • 250-5195 Rev .K 10/08 and Welcome to the Quadra-Fire Family ! Hearth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance. This commitment begins with our research of the market ...

  • Hearth and Home Technologies COLBAY-FS-B - page 3

    Page 3 Quadra-Fire • Columbia Bay • 250-5195 Rev . K - T ABLE OF CONTENTS - 10/08 Section 1: Listing and Code Approvals A. Appliance Certi fi cations ...................... 4 B. Glass Speci fi cations ............................ 4 C. BTU Speci fi cations .............................. 4 D. High Altitude Installations .................... 4 ...

  • Hearth and Home Technologies COLBAY-FS-B - page 4

    Page 4 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 1 Listing and Code Approvals The product is listed to ANSI standards for “V ented Gas Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recre- ational V ehicles” and "Gas Fired Appliances for use at High Altitudes" ...

  • Hearth and Home Technologies COLBAY-FS-B - page 5

    10/08 Page 5 Quadra-Fire • Columbia Bay • 250-5195 Rev . K NOTE: The following requirements reference various Massachusetts and national codes not contained in this document. For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including ...

  • Hearth and Home Technologies COLBAY-FS-B - page 6

    Page 6 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 2 Getting Started Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations. • Consult local building, fi re of fi cials or authorities having jurisdiction about restrictions, installation inspection, and ...

  • Hearth and Home Technologies COLBAY-FS-B - page 7

    10/08 Page 7 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 3 Appliance Location and Clearances A. Selecting Appliance Location NOTE: · Illustrations re fl ect typical installations and are FOR DESIGN PURPOSES ONL Y . · Illustrations/diagrams are not drawn to scale. · Actual installation may vary due to individual design preference. When sel ...

  • Hearth and Home Technologies COLBAY-FS-B - page 8

    Page 8 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 4 T ermination Locations A. V ent T ermination Minimum Clearances Figure 4.2 Multiple V ertical T ermination Figure 4.1 T ermination Clearances Figure 4.3 speci fi es minimum vent heights for various pitched roofs. Figure 4.3 Minimum Height from Roof to Lowest Discharge Fire Risk. Expl ...

  • Hearth and Home Technologies COLBAY-FS-B - page 9

    10/08 Page 9 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Figure 4.4 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inche s ............. clearances above grade, veran- da, porch, deck or balcony B = 12 i n ch es ............ c l e a r a nc e s to w i n do w o r d o o r that may be opened, or to per- mane ...

  • Hearth and Home Technologies COLBAY-FS-B - page 10

    Page 10 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 5 V ent Information A. V enting Components B. Use of Elbows In order to comply with applicable codes and product warranties, use only following venting components: • Hearth & Home T echnologies (HHT) • Security Chimney's Secure V ent Chimney System • Selkirk Metalbestos ...

  • Hearth and Home Technologies COLBAY-FS-B - page 11

    10/08 Page 1 1 Quadra-Fire • Columbia Bay • 250-5195 Rev . K D. How to Use the V ent Graph E. V enting Guidelines Figure 5.2 NOTES The maximum horizontal vent run is 15 ft. (5m) when the vertical vent rise is 10 ft. (3m). The minimum horizontal vent run is 11 in. (279mm). Horizontal sections require a 1/4 in. (6mm) rise for every 12 ft. (305mm) ...

  • Hearth and Home Technologies COLBAY-FS-B - page 12

    Page 12 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Female Locking Lugs Male Locking Lugs Step 1. Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance. F . Horizont ...

  • Hearth and Home Technologies COLBAY-FS-B - page 13

    10/08 Page 13 Quadra-Fire • Columbia Bay • 250-5195 Rev . K NOTE: (1) Installation requires a minimum of 6 in. (152mm) horizontal run of vent with a 1/4 in. (6mm) rise run towards the termination. Each 1 ft. (305mm) of horizontal venting must include a 1/4 in. (6mm) rise. Never allow the vent to run downward. This could cause high temperatures ...

  • Hearth and Home Technologies COLBAY-FS-B - page 14

    Page 14 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Step 5. Place the wall thimble cover over the pipe assembly and slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the vent cap assembly . It is important that the vent pipe extend into the vent cap a sufficient distance so as to result in a ...

  • Hearth and Home Technologies COLBAY-FS-B - page 15

    10/08 Page 15 Quadra-Fire • Columbia Bay • 250-5195 Rev . K NOTE : Maximum number of 45° elbows permitted for a vertical installation is eight, provided their installation does not decrease maximum allowable horizontal run (as specified by vent graph, on page 1 1). Figure 5.1 1 35 ft. (1 1m) MAXIMUM NOTE: Maximum vertical rise allowable is 35 ...

  • Hearth and Home Technologies COLBAY-FS-B - page 16

    Page 16 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K PLUMBER'S T APE CONNECTED TO W ALL STRAP WA L L STRAP TWO 45 DEGREE ELBOWS Step 2. S et the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Dr ...

  • Hearth and Home Technologies COLBAY-FS-B - page 17

    10/08 Page 17 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Step 7. Continue to assemble pipe sections until the height of the vent (before adding the termination cap) meets the minimum code requirements as outlined in the current CAN/CGA-B149 Installation Codes (in Canada), the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in USA), or local code ...

  • Hearth and Home Technologies COLBAY-FS-B - page 18

    Page 18 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 2. Cathedral Ceiling LEVEL CA THEDRAL CEILING SUPPORT BOX 2 in. (51mm) MIN. BELOW FINISHED CEILING CUT HOLE 1/8 in. (3mm) GREA TER IN SIZE THAN P A TTERN OF SUPPORT BOX AS IT IS PROJECTED ONTO ROOF LINE Figure 5.18 Figure 5.19 Step 1. Follow installation Steps 1 and 2 under vertical in ...

  • Hearth and Home Technologies COLBAY-FS-B - page 19

    10/08 Page 19 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 3. Class A Metal Chimney Figure 5.21 T op Adapter Sheet Metal Screws Flex Pipe HIGH WIND TERMINA TION CAP SHEET MET AL SCREWS DRILL FOUR 1/8 in. (3mm) DIAMETER HOLES Figure 5.22 Figure 5.23 Figure 5.24 Step 1. Remove existing chimney cap. Step 2. Measure the distance from the top of th ...

  • Hearth and Home Technologies COLBAY-FS-B - page 20

    Page 20 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 4. Existing Masonry Chimney Figure 5.25 TERMINA TION CAP FLASHING 4 in. (102mm) FLEX LINER TOP AD APTO R RETRO CONNECTOR 90 DEGREE ELBOW DIRECT VENT PIPE 10 in. x 10 in. (254mm x 254mm) FRAMED OPENING IN W ALL STUDW ALL MASONR Y CHIMNEY RETRO CONNECTOR FOUR MASONR Y BOL TS (NOT INCLUDE ...

  • Hearth and Home Technologies COLBAY-FS-B - page 21

    10/08 Page 21 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Step 7. If additional lengths of flex liner are needed to span the chimney height, use a flex coupler to connect the pieces of flex liner together . Connect the flex to the coupler by using four sheet metal screws for each side ( Figure 5.28 ). Fire Risk. Explosion Risk. • Do not let ...

  • Hearth and Home Technologies COLBAY-FS-B - page 22

    Page 22 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 6 Gas Information A. Fuel Conversions Before making gas connections ensure that the appliance being installed is compatible with the available gas type. Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a quali- fi ed technician ...

  • Hearth and Home Technologies COLBAY-FS-B - page 23

    10/08 Page 23 Quadra-Fire • Columbia Bay • 250-5195 Rev . K A B C Figure 6.5 T urn control knob to the OFF position, ensure that gas supply to the valve has been turned off. Using a T orx TH20, or slotted screwdriver , remove the three pressure reg- ulator mounting screws (A) , pressure regulator tower (B) , and diaphragm (C) . 2. V alve Regula ...

  • Hearth and Home Technologies COLBAY-FS-B - page 24

    Page 24 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K B. Gas Pressures If the pressure is not suf fi cient, ensure: 1) the piping used is large enough. 2) the supply regulator is adequately adjusted. 3) that the total gas load for the residence does not exceed the amount supplied. The supply regulator (the regulator that attaches directl ...

  • Hearth and Home Technologies COLBAY-FS-B - page 25

    10/08 Page 25 Quadra-Fire • Columbia Bay • 250-5195 Rev . K • A small amount of air will be in the gas supply lines. When fi rst lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally . Air only needs to be purged again if gas valve has been turned to t ...

  • Hearth and Home Technologies COLBAY-FS-B - page 26

    Page 26 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 7 Electrical Information A. Recommendation for Wire C. Standing Pilot Ignition System Wiring See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch. B. Connecting to the Appliance This appliance DOES NOT require 1 10 V AC supply for operation. A w ...

  • Hearth and Home Technologies COLBAY-FS-B - page 27

    10/08 Page 27 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Figure 7.1 CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. Shock hazard. • Replace damaged wire with type 105 O C rated wire. • Wire must have high temperatur ...

  • Hearth and Home Technologies COLBAY-FS-B - page 28

    Page 28 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 8 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Accessories Install approved accessories per instructions included with accessories. Refer to Section 12 for appropriate accesso- ries. Shock or fi re risk. Use ONL Y o ...

  • Hearth and Home Technologies COLBAY-FS-B - page 29

    10/08 Page 29 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Figure 8.4 Holding both sides of the metal refractory brick piece, pull slightly together and rotate out of the firebox. INST ALL NEW BRICK SET Figure 8.5 Install rear panel, gently wedging it between sup- port shelf and baffle base. Install the brick brackets that are enclosed with th ...

  • Hearth and Home Technologies COLBAY-FS-B - page 30

    Page 30 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Figure 8.9 Place right and left front logs on burner in the grooves provided on the burner surface. F . Mineral Wool • Follow ember placement instructions in manual. • Do NOT place embers directly over burner ports. • Replace ember material annually . Explosion Risk. W ARNING Imp ...

  • Hearth and Home Technologies COLBAY-FS-B - page 31

    10/08 Page 31 Quadra-Fire • Columbia Bay • 250-5195 Rev . K INCLUDED IN KIT : Blower; 2 female spade wire connec- tors. T urn off power supply . Remove blower housing from appliance, if necessary . Disassemble housing if needed, retaining all fasteners, and remove the blower . Reassemble blower in housing using fasteners previously removed. Rei ...

  • Hearth and Home Technologies COLBAY-FS-B - page 32

    Page 32 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Refer to the vent graph on page 1 1. If your installation falls within the range of the gray shaded area of graph, it may be necessary to make an adjustment to the vertical damper to improve the flame appearance in your appliance. Figure 8.14 The shutter is located on the underside of ...

  • Hearth and Home Technologies COLBAY-FS-B - page 33

    10/08 Page 33 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 9 Operating Instructions A. Before Lighting Appliance Read this entire manual prior to using the appliance. Failure to follow the instructions may result in property damage, bodily injury, or even death. Glass door must be in place when appliance is operating. Risk of: • Combustion F ...

  • Hearth and Home Technologies COLBAY-FS-B - page 34

    Page 34 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K C. Lighting Appliance 1. Set the thermostat to lowest setting. 2. T urn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "OFF" position. FOR YOUR SAFETY READ BEFORE LIGHTING FOR YOUR SAFETY READ ...

  • Hearth and Home Technologies COLBAY-FS-B - page 35

    10/08 Page 35 Quadra-Fire • Columbia Bay • 250-5195 Rev . K D. After Appliance is Lit When you light your appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours ...

  • Hearth and Home Technologies COLBAY-FS-B - page 36

    Page 36 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 10 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service person in the diagnosis of a problem and the corrective ...

  • Hearth and Home Technologies COLBAY-FS-B - page 37

    10/08 Page 37 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Symptom Possible Cause Corrective Action 3. (Continued) c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter at the thermopile terminals. The millivolt meter should read greater than 125mV . If the reading is ...

  • Hearth and Home Technologies COLBAY-FS-B - page 38

    Page 38 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 11 Maintaining and Servicing Y our Appliance Although the frequency of your appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance check-up at the beginning of each heating season. Risk of injur ...

  • Hearth and Home Technologies COLBAY-FS-B - page 39

    10/08 Page 39 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Inspect Maintenance T asks Doors 1. Inspect for scratches, dents or other damage and repair as necessary . 2. V erify no obstructions to air fl ow . 3. V erify maintenance of proper clearance to combustible household objects. Gasket Seal, Glass Assembly and Glass 1. Inspect gasket sea ...

  • Hearth and Home Technologies COLBAY-FS-B - page 40

    Page 40 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K B. Service and Maintenance Log Date of Service Performed By Description of Service ...

  • Hearth and Home Technologies COLBAY-FS-B - page 41

    10/08 Page 41 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 12 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For clearances refer to Section 3. Figure 12.1 Appliance Dimensions A B F G H I J K C D E Location Inches Millimeter Location Inches Millimeter A 22-1/2 572 G 1 1- ...

  • Hearth and Home Technologies COLBAY-FS-B - page 42

    Page 42 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K B. V ent Components Diagram Figure 12.2 SLP Series V ent Components 9-7/16 in. 240 mm 6-9/16 in. 167 mm 6-9/16 in. 167 mm 6-9/16 in. 167 mm 6-9/16 in. 167 mm 6 in. 152 mm 6-1/2 in. 165 mm 9-3/4 in. 248 mm 9-1/4 in. 235 mm 7-1/4 in. 184 mm 7-1/4 in. 184 mm 5-1/4 in. 133 mm 25-1/4 in. 64 ...

  • Hearth and Home Technologies COLBAY-FS-B - page 43

    10/08 Page 43 Quadra-Fire • Columbia Bay • 250-5195 Rev . K C. V ent Components List COMPONENTS SLP-WT -BK Ceiling Support / W all Thimble, Black SLP-CCS-BK Cathedral Ceiling Support, Black SLP6-BK 6 inch Pipe Length, Black SLP4-BK 9 inch Pipe Length, Black SLP12-BK 12 inch Pipe Length, Black SLP34-BK 24 inch Pipe Length, Black SLP36-BK 36 inch ...

  • Hearth and Home Technologies COLBAY-FS-B - page 44

    Page 44 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K Service Parts Diagram Part number list on following page. Log Set Assembly COLBA Y -FS-B Columbia Bay Free Standing 1 2 3 4 5 6 7 8 9 R D. Service Parts List Beginning Manufacturing Date: Feb 2005 Ending Manufacturing Date: ______  ...

  • Hearth and Home Technologies COLBAY-FS-B - page 45

    10/08 Page 45 Quadra-Fire • Columbia Bay • 250-5195 Rev . K IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION COMMENTS P ART NUMBER L ...

  • Hearth and Home Technologies COLBAY-FS-B - page 46

    Page 46 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K D. Service Parts R IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked In Depot ITEM DESCRIPTION COMM ...

  • Hearth and Home Technologies COLBAY-FS-B - page 47

    10/08 Page 47 Quadra-Fire • Columbia Bay • 250-5195 Rev . K E. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed i ...

  • Hearth and Home Technologies COLBAY-FS-B - page 48

    Page 48 10/08 Quadra-Fire • Columbia Bay • 250-5195 Rev . K E. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/o ...

  • Hearth and Home Technologies COLBAY-FS-B - page 49

    Page 49 Quadra-Fire • Columbia Bay • 250-5195 Rev . K 10/08 Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HHT INDUSTRIES CONT ACT INFORMA TION : Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer , please visit our web site www .quadra ? ...

Produzent Hearth and Home Technologies Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Hearth and Home Technologies COLBAY-FS-B erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Hearth and Home Technologies
- Bedienungsanleitungen COLBAY-FS-B
- Produktkarten Hearth and Home Technologies
- Informationsbroschüren
- oder Energieetiketten Hearth and Home Technologies COLBAY-FS-B
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Hearth and Home Technologies COLBAY-FS-B.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Hearth and Home Technologies COLBAY-FS-B, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Hearth and Home Technologies COLBAY-FS-B. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Hearth and Home Technologies COLBAY-FS-B ansehen.

Die komplette Bedienungsanleitung des Geräts Hearth and Home Technologies COLBAY-FS-B, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Hearth and Home Technologies COLBAY-FS-B hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Hearth and Home Technologies COLBAY-FS-B verständlich ist.

Eine gänzliche Bedienungsanleitung von Hearth and Home Technologies sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Hearth and Home Technologies COLBAY-FS-B bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Hearth and Home Technologies COLBAY-FS-B befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Hearth and Home Technologies COLBAY-FS-B, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Hearth and Home Technologies COLBAY-FS-B - die uns die ersten Schritte während der Nutzung von Hearth and Home Technologies COLBAY-FS-B erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Hearth and Home Technologies COLBAY-FS-B hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Hearth and Home Technologies COLBAY-FS-B im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Hearth and Home Technologies COLBAY-FS-B?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Hearth and Home Technologies COLBAY-FS-B nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Hearth and Home Technologies COLBAY-FS-B hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)