Bedienungsanleitung Hearth and Home Technologies Cinch Pipe & Termination Cap System

12 Seiten 1.86 mb
Download

Zur Seite of 12

Summary
  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 1

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 1 TM TM Models: Cinch Pipe & T ermination Cap System Installation Instructions If you need assistance during installation, contact your local dealer or the T echnical Serices Dept., Hearth & Home T echnologie s Inc., phone 1-800-927-6841 or 1-8 ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 2

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 2 DVP-TV V ertical termination cap. Includes storm collar and fastener pack. DVP-TB1 Basement/window well termination cap. Includes fas- tener pack. DVP-TRAP2 Horizontal termination cap with 4 in. telescoping fl ue. Includes DVP-WS wall shield with he ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 3

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 3 COOL ADD Cap shield DRC-RADIUS Cap shield DVP-TRAPFL DVP-TRAP1 or DVP-TRAP2 termination cap rain fl ashing DVP-TRAP1 DVP-TRAP2 T ermination Cap DVP-TRAPFL Flashing Components Description DRC-RADIUS Cap Shield COOL-ADDM Cap Shield - pack of six DVP-T ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 4

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 4 V ent depth is measured from the back of the appliance to the outer edge of the exterior wall. See T able 1 and Figure 1. Figure 1 - Measuring Required V ent Depth T able 1 TRAP CAP SPECIFICA TION CHART Appliance DVP-TRAPK1 T op V ent Depth DVP-TRAP1 ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 5

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 5 3 in. (76 mm) top clearance 1 in. (25 mm) clearance bottom & sides Heat Shield Wa l l Shield Heat Shield WA L L Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). Figure 2.2 Horizontal V enting Clearances to Combustible Materi- al ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 6

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 6 C. Assemble V ent Sections Figure 2.5 Lances A B Figure 2.6 Inner/Outer A B Figure 2.7 Snapped CORRECT INCORRECT Make sure the seams are not aligned to prevent unintentional disconnection. Figure 2.8 Seams Fire Risk Exhaust Fumes Risk • Overlap pip ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 7

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 7 Assemble Minimum Installation (MI) Sections MI sections are non-unitized so that they can be cut to a specifi c length. Cut these sections to length from the non- expanded end (see Figure 2.9). They can then be attached by fi rst connecting the exp ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 8

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 8 Secure the V ent Sections V ertical sections of pipe must be supported every 8 ft after the 25 ft maximum unsupported rise. The vent support or plumber ’s strap (spaced 120° apart) may be used to do this (see Figures 2.12 and 2.13). Horizontal sec ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 9

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 9 Burn Risk • Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap. W ARNING Do NOT connect a pipe section to a termination cap without using the telescoping fl ue section found on the terminat ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 10

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 10 F . V ertical Penetration Framing Note: The fi restop spacer is not required if at tic insulat ion shield is used. Install Attic Insulation Shield • Frame opening for attic insulation shield. • Attic insulation shield may be installed above or ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 11

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 11 Figure 2.20 Secure with Screws G. Install Roof Flashing and V ertical T ermination Cap T o attach the vertical termination cap, slide the inner collar of the cap into the inner fl ue of the pipe section and place the outer collar of the cap over th ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 12

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 12 H. Assemble and Install Storm Collar Connect both halves of the storm collar with two screws (see Figure 2.21). Wrap the storm collar around the exposed pipe section and align brackets. Insert a bolt (provided) through the brackets and tighten nut t ...

Produzent Hearth and Home Technologies Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Hearth and Home Technologies Cinch Pipe & Termination Cap System erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Hearth and Home Technologies
- Bedienungsanleitungen Cinch Pipe & Termination Cap System
- Produktkarten Hearth and Home Technologies
- Informationsbroschüren
- oder Energieetiketten Hearth and Home Technologies Cinch Pipe & Termination Cap System
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Hearth and Home Technologies Cinch Pipe & Termination Cap System.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Hearth and Home Technologies Cinch Pipe & Termination Cap System, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Hearth and Home Technologies Cinch Pipe & Termination Cap System. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Hearth and Home Technologies Cinch Pipe & Termination Cap System ansehen.

Die komplette Bedienungsanleitung des Geräts Hearth and Home Technologies Cinch Pipe & Termination Cap System, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Hearth and Home Technologies Cinch Pipe & Termination Cap System hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Hearth and Home Technologies Cinch Pipe & Termination Cap System verständlich ist.

Eine gänzliche Bedienungsanleitung von Hearth and Home Technologies sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Hearth and Home Technologies Cinch Pipe & Termination Cap System bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Hearth and Home Technologies Cinch Pipe & Termination Cap System befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Hearth and Home Technologies Cinch Pipe & Termination Cap System, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Hearth and Home Technologies Cinch Pipe & Termination Cap System - die uns die ersten Schritte während der Nutzung von Hearth and Home Technologies Cinch Pipe & Termination Cap System erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Hearth and Home Technologies Cinch Pipe & Termination Cap System hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Hearth and Home Technologies Cinch Pipe & Termination Cap System im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Hearth and Home Technologies Cinch Pipe & Termination Cap System?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Hearth and Home Technologies Cinch Pipe & Termination Cap System nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Hearth and Home Technologies Cinch Pipe & Termination Cap System hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)