    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 1 TM TM Models: Cinch Pipe & T ermination Cap System Installation Instructions If you need assistance during installation, contact your local dealer or the T echnical Serices Dept., Hearth & Home T echnologie s Inc., phone 1-800-927-6841 or 1-8 ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 2

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 2 DVP-TV V ertical termination cap. Includes storm collar and fastener pack. DVP-TB1 Basement/window well termination cap. Includes fas- tener pack. DVP-TRAP2 Horizontal termination cap with 4 in. telescoping fl ue. Includes DVP-WS wall shield with he ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 3

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 3 COOL ADD Cap shield DRC-RADIUS Cap shield DVP-TRAPFL DVP-TRAP1 or DVP-TRAP2 termination cap rain fl ashing DVP-TRAP1 DVP-TRAP2 T ermination Cap DVP-TRAPFL Flashing Components Description DRC-RADIUS Cap Shield COOL-ADDM Cap Shield - pack of six DVP-T ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 4

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 4 V ent depth is measured from the back of the appliance to the outer edge of the exterior wall. See T able 1 and Figure 1. Figure 1 - Measuring Required V ent Depth T able 1 TRAP CAP SPECIFICA TION CHART Appliance DVP-TRAPK1 T op V ent Depth DVP-TRAP1 ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 5

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 5 3 in. (76 mm) top clearance 1 in. (25 mm) clearance bottom & sides Heat Shield Wa l l Shield Heat Shield WA L L Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). Figure 2.2 Horizontal V enting Clearances to Combustible Materi- al ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 6

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 6 C. Assemble V ent Sections Figure 2.5 Lances A B Figure 2.6 Inner/Outer A B Figure 2.7 Snapped CORRECT INCORRECT Make sure the seams are not aligned to prevent unintentional disconnection. Figure 2.8 Seams Fire Risk Exhaust Fumes Risk • Overlap pip ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 7

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 7 Assemble Minimum Installation (MI) Sections MI sections are non-unitized so that they can be cut to a specifi c length. Cut these sections to length from the non- expanded end (see Figure 2.9). They can then be attached by fi rst connecting the exp ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 8

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 8 Secure the V ent Sections V ertical sections of pipe must be supported every 8 ft after the 25 ft maximum unsupported rise. The vent support or plumber ’s strap (spaced 120° apart) may be used to do this (see Figures 2.12 and 2.13). Horizontal sec ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 9

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 9 Burn Risk • Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap. W ARNING Do NOT connect a pipe section to a termination cap without using the telescoping fl ue section found on the terminat ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 10

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 10 F . V ertical Penetration Framing Note: The fi restop spacer is not required if at tic insulat ion shield is used. Install Attic Insulation Shield • Frame opening for attic insulation shield. • Attic insulation shield may be installed above or ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 11

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 11 Figure 2.20 Secure with Screws G. Install Roof Flashing and V ertical T ermination Cap T o attach the vertical termination cap, slide the inner collar of the cap into the inner fl ue of the pipe section and place the outer collar of the cap over th ...

  • Hearth and Home Technologies Cinch Pipe & Termination Cap System - page 12

    Hearth & Home T echnologies Inc. • Cinch Pipe & T erm Caps • 4033-900 Rev K • 05/05 12 H. Assemble and Install Storm Collar Connect both halves of the storm collar with two screws (see Figure 2.21). Wrap the storm collar around the exposed pipe section and align brackets. Insert a bolt (provided) through the brackets and tighten nut t ...

メーカー Hearth and Home Technologies カテゴリー Indoor Fireplace

Hearth and Home Technologies Cinch Pipe & Termination Cap Systemのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Cinch Pipe & Termination Cap Systemの取扱説明書
- Hearth and Home Technologiesの製品カード
- パンフレット
- またはHearth and Home Technologies Cinch Pipe & Termination Cap Systemの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Hearth and Home Technologies Cinch Pipe & Termination Cap Systemの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Hearth and Home Technologies Cinch Pipe & Termination Cap Systemの取り付け説明書、サービスマニュアル、簡易説明書、またはHearth and Home Technologies Cinch Pipe & Termination Cap Systemのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Hearth and Home Technologies Cinch Pipe & Termination Cap Systemの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Hearth and Home Technologies Cinch Pipe & Termination Cap Systemデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHearth and Home Technologies Cinch Pipe & Termination Cap Systemを使用するのを助ける技術的文書のことです。説明書は通常、全てのHearth and Home Technologies Cinch Pipe & Termination Cap Systemユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Hearth and Home Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Hearth and Home Technologies Cinch Pipe & Termination Cap Systemの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHearth and Home Technologies Cinch Pipe & Termination Cap Systemの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Hearth and Home Technologies Cinch Pipe & Termination Cap Systemに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Hearth and Home Technologies Cinch Pipe & Termination Cap Systemデバイスの基本機能を使うにあたってのヒント。 Hearth and Home Technologies Cinch Pipe & Termination Cap Systemのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Hearth and Home Technologies Cinch Pipe & Termination Cap Systemに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHearth and Home Technologies Cinch Pipe & Termination Cap Systemのメーカー/サービスへの連絡先に関する情報。

Hearth and Home Technologies Cinch Pipe & Termination Cap Systemについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHearth and Home Technologies Cinch Pipe & Termination Cap Systemの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHearth and Home Technologies Cinch Pipe & Termination Cap Systemで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)